Morton MHY Скачать руководство пользователя страница 18

   18

                                             Morton

®

Water Softener Installation & Operation Manual

FIG. 34

Broom

Handle

Pencil

Mark

1” - 2”

Salt
Salt

Bridge
Water

Level

Push Tool into

Salt Bridge to

Break

Refilling with Salt

Lift the salt lid and check the salt storage level fre-

quently.  If the water softener uses all the Morton

®

Clean and Protect

or Clean and Protect

Plus Rust

Defense

Pellets before you refill it, you will experi-

ence hard water.  Until you have established a refilling

routine, check the salt every two or three weeks.

Always add if less than 1/4 full.  Be sure the brinewell

cover is on.

NOTE:

In humid areas, it is best to keep the salt stor-

age level lower, and to refill more often to

avoid salt “bridging”.

Recommended Salt:

We recommend using Morton

®

Clean and Protect

or Clean and Protect

Plus Rust

Defense

Pellets in the familiar yellow bag.  For soft

water, nothing works harder.  Guaranteed

®

.

Salt Not Recommended:

Rock salt, high in impuri-

ties, block, granulated, table, ice melting, ice cream

making salts, etc., are not recommended.

Salt with Iron Removing Additives:

Some salts

have an additive to help a water conditioner handle

iron in a water supply.  For this we recommend

Morton

®

Rust Remover Super Pellets

®

in the green bag.

Breaking a Salt Bridge

Sometimes, a hard crust or salt “bridge” forms in the

brine tank.  It is usually caused by high humidity or the

wrong kind of salt.  When the salt “bridges,” an empty

space forms between the water and the salt.  Then,

salt will not dissolve in the water to make brine.

Without brine, the resin bed is not recharged and hard

water will result.
If the storage tank is full of salt, it is difficult to tell if

you have a salt bridge.  A bridge may be underneath

loose salt.  Take a broom handle, or like tool, and hold

it next to the water softener.  Measure the distance

from the floor to the rim of the water softener.  Then,

carefully push the broom handle straight down into the

salt.  If a hard object is felt before the pencil mark is

even with the top, it is most likely a salt bridge.

Carefully push into the bridge in several places to

break it.  Do not use any sharp or pointed objects as

you may puncture the brine tank.  Do not try to break

the salt bridge by pounding on the outside of the salt

tank.  You may damage the tank.

Routine Maintenance

Power Outage Memory

If electrical power to the softener is interrupted, the

time display is blank, but the electronic controller

keeps correct time for several hours.  When power is

restored, you must reset the present time only if the

display is flashing.  All other settings are maintained

and never require resetting unless a change is

desired.  If the time is flashing after a long power out-

age, the softener continues to work as it should to

provide you with soft water.  However, regenerations

may occur at the wrong time of day until you reset the

clock to the correct time of day.

NOTE:

If the water softener was regenerating when

power was lost, it will now finish the cycle.

Customizing

Features / Options

Содержание MHY

Страница 1: ...water softener to store For best results use Morton Clean and Protect or Morton Clean and Protect Plus Rust Defense Pellets in your water softener 7358514 Rev D 3 8 19 Water Softener Installation and...

Страница 2: ...mula that works with your softener to help prevent mineral buildup and keep your home s pipes and appliances working at their best Whether you re looking to remove iron and fight buildup or extend you...

Страница 3: ...shipping damage and parts loss Also inspect and note any damage to the shipping carton Remove and discard or recycle all packing materials To avoid loss of small parts we suggest you keep the small pa...

Страница 4: ...rated salt efficiency is measured by lab oratory tests described in NSF ANSI Standard 44 These tests represent the maximum possible efficiency that the system can achieve Operational efficiency is the...

Страница 5: ...alt Dose 50 3 gallons Rated Service Flow Rate 6 5 gpm Amount of High Capacity Ion Exchange Resin 0 94 cu ft Pressure Drop at Rated Service Flow 9 6 psig Water Supply Max Hardness 95 gpg Water Supply M...

Страница 6: ...ferric Ferrous clear water iron is soluble and dissolves in water This water softener will reduce moderate amounts of this type of iron see specifications Ferrous clear water iron is usually detected...

Страница 7: ...t water over 100 F Freezing temperatures or hot water damage voids the warranty To condition all water in the home install the water softener close to the water supply inlet and upstream of all other...

Страница 8: ...eet Avoid elevating the hose more than 8 feet above the floor Make the valve drain line as short and direct as possible Inlet Outlet Plumbing Options Always install either a single bypass valve provid...

Страница 9: ...ne valve back into the bottom of the brinewell and reinstall the brinewell cover 3 Install the brine tank overflow grommet and elbow into the 13 16 diameter hole in the back of the salt storage tank w...

Страница 10: ...o place from the top down as shown in Figures 12 13 IMPORTANT Be sure the clips snap firmly into place so the single bypass valve will not pull out Step 4 Complete Inlet and Outlet Plumbing Measure cu...

Страница 11: ...oftener located downstream from the water softener 2 Place the single bypass valve or 3 valve bypass in bypass position See Figures 7 8 3 Fully open the main water supply valve Run water until there i...

Страница 12: ...ials used to make the unit will not infect or contaminate your water supply and will not cause bacteria to form or grow However during shipping storage installation and operation bacteria could get in...

Страница 13: ...UP or q DOWN buttons to set the present time Up moves the display ahead down sets the time back Be sure AM or PM is correct Low Salt Light Clean Reminder When the water softener is connected to electr...

Страница 14: ...The salt level scale on the brinewell inside the tank has numbers from 0 to 8 See Fig 21 Observe the highest number the leveled salt is at or closest to 3 Press the SELECT button to display the words...

Страница 15: ...tiate more frequent recharges However it will operate at 4000 grains per pound of salt or higher If you wish to turn the Salt Efficiency feature ON icon will show in the display follow the instruction...

Страница 16: ...ash during the regeneration When completed full water condition ing capacity is restored RECHARGE NOW initiated FIG 25 RECHARGE TONIGHT initiated FIG 26 FIG 29 FIG 28 FIG 27 Clean Feature This feature...

Страница 17: ...to 12 PM at the 12 hr default setting To change this setting 1 Press and hold the SELECT button until the screen in Figure 27 is displayed 2 Press the SELECT button three times so that 12 hr or 24 hr...

Страница 18: ...space forms between the water and the salt Then salt will not dissolve in the water to make brine Without brine the resin bed is not recharged and hard water will result If the storage tank is full of...

Страница 19: ...t Screen Gasket Flow Plug HVDC Housing Ferrule Nut Cone Screen Flow Plug Install with lettered side up concave side down Cleaning the Nozzle Venturi A clean nozzle venturi See Figure 35 is a necessity...

Страница 20: ...correct switch operation NOTE Be sure water is in contact with the salt and not separated by a salt bridge See Breaking A Salt Bridge section 5 While in this diagnostic screen the following infor mati...

Страница 21: ...lug brine tub ing or brine valve riser pipe Manual Advance Regeneration Check 2 After observing fill press the RECHARGE button to move the softener s valve into the brine position A slow flow of water...

Страница 22: ...r Softener Installation Operation Manual Water Softener and Filter Exploded View 8 7 6 5 26 28 15 16 18 19 20 11 22 23 24 25 8 6 3 9 10 7 5 2 1 21 14 13 17 27 12 Valve Assembly See Pages 24 25 for par...

Страница 23: ...7 Clamp Section 2 req 8 Retainer Clip 2 req 9 7334696 Repl Resin Tank 10 x 35 10 0502272 Resin 1 cu ft 7301619 Activated Carbon 11 7369536 Repl Brine Tank 12 7369544 Rim 13 7369552 Top Cover order de...

Страница 24: ...Softener Installation Operation Manual Valve Exploded View 50 52 53 51 55 56 59 58 57 60 61 66 67 62 63 64 68 69 70 71 75 65 76 77 79 78 80 81 82 Wear Strip Seal Cross section View 83 84 85 86 87 88 8...

Страница 25: ...bly 3 4 in cluding 2 O Rings See Key No 72 72 7337571 O Ring 15 16 x 1 3 16 pack of 4 7113040 Turbine Support Assembly including 2 O Rings See Key No 72 1 ea of Key Nos 73 74 73 Turbine Support Shaft...

Страница 26: ...ll not be responsible for reimbursement for labor trans portation removal installation or other expenses which may be incurred by Purchaser in connection with replacement or repair or returning the pr...