15
INSTALLATION
In order to adapt the cooker to burn a different
type of gas, you should:
exchange nozzles (see tables below),
adjust the “economical” flame.
Burner flame
Re-arming from liquid
gas
to natural gas
Re-arming from natural
gas
to liquid gas
Full
1. Exchange a burner noz
-
zle for the appropriate type
according to the nozzle
table.
Economical
1. Exchange a burner
nozzle for the appropriate
type according to the noz
-
zle table.
2. Unscrew an adjusting
bolt slightly and adjust the
flame size.
2. Screw in an adjusting
bolt slightly and check the
flame size.
In order to perform adjusting operations, take off the knobs. Adjusting elements of the
oven burner are accessible after drawing out the oven chamber floor.
Caution!
The cookers provided by the manufacturer
have burners which are factory-adapted to
use the gas specified on their data plates and
guarantee cards.
Burner of DEFENDI type
(according to the “DEFENDI” symbol on burner components)
Type of gas
Burner
auxiliary
gas injector diameter
[mm]
medium
gas injector diameter
[mm]
large
gas injector diameter
[mm]
nominal
thermal power
1,00 kW
nominal
thermal power
1,75 kW
nominal
thermal power
3,00 kW
G20 2H 20 mbar
0,77
0,97
1,29
G30/31 3+ 28-30/37
mbar
0,50
0,65
0,87
Содержание MKG-64201