RESISTANCE
Range Resolution
Accuracy
400
Ω
0.1
Ω
±
1.2% of rdg
±
1 digit
4k
Ω
1
Ω
40k
Ω
10
Ω
400k
Ω
0.1k
Ω
4M
Ω
1k
Ω
40M
Ω
10k
Ω
±
2.0% of rdg
±
3 digits
Overload Protection: 250V dc or rms. ac for all ranges.
CAPACITANCE MEASUREMENT
Range Resolution
Accuracy
40nF
10pF
±
4.0% of rdg
±
10 digits
400nF
0.1nF
4
µ
F
1nF
40
µ
F
10nF
−
Overload Protection: 250V dc or rms. ac for all ranges.
FREQUENCY MEASUREMENT
Range Resolution
Accuracy
40Hz
0.01Hz
±
2.0% of rdg
±
1 digit
400Hz
0.1Hz
4kHz
1Hz
40kHz
10Hz
100kHz
0.1kHz
-17-