background image

Dust bag condition

When the cleaner is switched on, if the

dust bag condition indicator is continuously
showing red (or if the suction is reduced) the
bag must be replaced and the filters
cleaned.

If it is still showing red after emptying the

dust bag and cleaning the filters, check to
see if the hose is blocked.

Changing the dust bag 

E

Unplug power cable from wall socket.

2

Remove the front by pressing the release
lever at the top.

3

Remove the old dust bag by holding the
cardboard tab and pull towards you.
Remove carefully to avoid dust/dirt
spilling from dust bag and dispose.

4

Take a new dust bag and fold over the
top tab at the crease. Holding the
cardboard tab, push the bag over the
opening of the dirt discharge tube until it
is seated against the rear of the
enclosure.

5

The front panel will not close unless the
dustbag is correctly fitted due to the
safety bag interlock. Always check the
pre-motor and post motor filters every
time you change the dust bag. 

6

Once the new dust bag is in place,
replace the front panel by aligning the
bottom locking tabs with the slots in the
body, close cover slowly allowing the
front panel to snap in place.  The latch
will self lock.

Changing the filters 

F

Everytime a new bag is fitted, the filters

should be taken out and cleaned. Failure to
clean the filters will reduce the suction and
will damage the motor if used for prolonged
periods. This may invalidate the guarantee. If
the filters become damaged they must be
replaced.

IMPORTANT: Do not operate the cleaner

without the filters in place.

1

Remove the front cover of the cleaner.

2

The pre-motor filter is located underneath
the bag and the exhaust filter is below
facing forward. To remove the pre-motor
filter, simply slide it forward. To remove
the exhaust motor filter, pull the locking
tab on the right and it will snap out. 

3

Remove the filters from their holders by
unclipping and shake vigorously over a
dustbin. The pre-motor filter may also be
washed in warm water. Do not use
detergents. The filter must be completely
dry before re-fitting. Allow filter to dry
naturally, do not overheat. The exhaust
filter is non-washable.

4

Replace front cover.

5

E

F

Î

8407 Upright ib 4  03/12/2002  1:18 PM  Page 5

Содержание IB73300

Страница 1: ...as it should please check Dustbag It is important to replace them when full otherwise the performance of the cleaner will be impaired Filters It is important that the filters are cleaned and replaced regularly to allow air through the appliance Blockages Check the hose for blockages Belt Check and replace damaged or broken belt 8407 Upright ib 4 03 12 2002 1 18 PM Page 1 ...

Страница 2: ...ken glass sharp objects or liquids Never modify the cleaner in any way Always disconnect the appliance from the mains supply after use or prior to cleaning or replacing dust bags The appliance should never be left running unsupervised Repairs to electrical appliances are only to be undertaken by trained personnel Unprofessional repairs can be dangerous for users Use only genuine Morphy Richards sp...

Страница 3: ...Full bag indicator  On Off switch Ê Front cover release Á Floor nozzle with powered brush Ë Handle release È Carrying handle Í Cord storage with quick release cleat Î Safety bag interlock Ï Belt cover Ì Belt tunnel blanking plate Ó Brush end plates 3 A Accessories included Á Ê fl Í È Â fi Ë Extension tubes Crevice tool Furniture brush 8407 Upright ib 4 03 12 2002 1 18 PM Page 3 ...

Страница 4: ...he carpet height adjustment knob to the desired position 3 Release the mains cable by revolving the quick release cleat through 180º and extend the cable fully 4 Plug the cable into the mains socket 5 Step on the handle release button to release the handle to the desired position D 6 Press the on off button to the on position IMPORTANT To prevent damage to carpets never leave the cleaner switched ...

Страница 5: ... place replace the front panel by aligning the bottom locking tabs with the slots in the body close cover slowly allowing the front panel to snap in place The latch will self lock Changing the filters F Everytime a new bag is fitted the filters should be taken out and cleaned Failure to clean the filters will reduce the suction and will damage the motor if used for prolonged periods This may inval...

Страница 6: ...ip the cover from the front of the floor nozzle H 6 If the belt has broken remove any loose pieces before replacing 7 Lift the belt cover Ï off 8 Grasp the brush at both ends and lift straight up I 9 Remove the belt tunnel blanking plate Ì 10 Place one end of the new belt over the motor shaft and the other around the pulley end of the brush J 11 Make sure both brush end plates Ó are fitted 12 Plac...

Страница 7: ...more likely able to help than the store from where you bought the product Please have the following information ready to enable our staff to deal with your query quickly Name of the product Model number as shown on the underside of the appliance 7 8407 Upright ib 4 03 12 2002 1 19 PM Page 7 ...

Страница 8: ...ample bags and filters shall have been regularly cleaned or replaced Morphy Richards shall not be liable to replace or repair the goods under the terms of the Guarantee where 1 The fault has been caused or is attributable to accidental use mis use negligent use or used contrary to the manufacturers recommendations or where the fault has been caused by power surges or damage caused in transit 2 The...

Отзывы: