Morphy Richards CYCLONIC BAGLESS VACUUM CLEANER - REV 4 Скачать руководство пользователя страница 6

6

6

UK Helpline 0870 060 2604 

Replacement Parts 0870 167 663

Ireland Helpline 1800 409119

6

SAFETY CUT-OUT

If the cleaner overheats a motor
protection thermostat will
automatically switch the motor
off. If this happens,

switch the

cleaner off, unplug from the
power supply and leave the
cleaner to cool for at least
60 minutes

. Check the

airways for blockages, empty
dust canister and clean the
filters before restarting.

CLEANING THE 
FILTERS

To maintain suction the
pleated filter must be
shaken clean each time the
dust canister is emptied.

Failure to clean the filter will
reduce suction and could
damage the motor if used for a
prolonged period. This may
invalidate the guarantee. If the
filters become damaged they
must be replaced.

Pleated filter

This must be shaken clean at
every emptying to maintain
suction. To thoroughly clean it
wash it regularly. 

To remove it from the dust
canister lid turn the filter 1/4
turn anti-clockwise. 

G

Wash in

warm water (no detergent) and
allow to air dry before refitting.
The spare pleated filter allows
one filter to be washed and
dried whilst the other is in use.

Motor protection filter

H

The motor protection filter 

Ò

is

located underneath the dust
canister

1

Remove the dust canister.

2

Lift out the filter and shake over
a dustbin.

The filter may also be washed in
water (no detergents) but must
be totally dry before re-fitting.

3

Replace the filter

Exhaust filter 

I

The exhaust filter is located
below the dust canister
compartment.

1

Remove the front cover.

2

Remove the exhaust filter 

Ú

by

pulling forward at the top and
lift it away. 

3

Take the filter out of the cage
and shake vigorously over a
dustbin. The filter may also be
washed in warm water. Do not
use detergents. The filter must
be completely dry before re-
fitting. Allow filters to air dry
naturally.

4

Replace the filter and front
cover.

Changing the belt

If the brush bar stops rotating it
is likely that the drive belt has
snapped (usually because the
brush has been stalled). A spare
belt is supplied. Replacement
belts can also be obtained from
Morphy Richards. 

Accessing the floor 
nozzle 

I

1

Disconnect the cleaner from the
mains supply.

2

Put switch to off position.

3

Remove front cover and dust
canister.

4

Press the handle release pedal
and place the cleaner face
down, in a flat position on a soft
surface (eg carpet).

5

Using a flat bladed screwdriver
or a coin, rotate the three cover
fixings, a quarter of a turn, from
lock to unlock

.

6

Lift the base cover, from the rear
fixing area first, the cover will
rotate forward. Unhook cover
from front edge and remove 

M

.

H

G

I

73360 rev4  11/7/06  14:43  Page 6

Содержание CYCLONIC BAGLESS VACUUM CLEANER - REV 4

Страница 1: ...ety cut out If the air flow is bloked or the filters are not regulary cleaned a thermostat may operate If this happens switch off and disconnect from the mains supply Clear any blockage empty and clean the filters Allow 60 minutes for the thermostat to reset Belt Check and replace damaged or broken belt Height adjustment The height adjustment only comes into effect when the handle is released by t...

Страница 2: ... running unsupervised This appliance is intended for domestic use only Misuse or use for commercial or any other purpose will render the guarantee invalid Always disconnect the appliance from the main supply after use To protect against fire electric shock and personal injury do not immerse cord plug or cleaner in water or other liquid Product safety Never use the appliance without the filters bei...

Страница 3: ... brush Ë Hose clip slot È Handle release pedal Í Hose connector Î Dust canister release shown page 5 Ï Dust canister lid Ì Pleated circular filter Ó Dust canister Ô Central mesh filter Canister handle Ò Motor protection filter shown page 6 Ú Exhaust filter page 6 Û Belt cover shown page 7 Ù Brush bar page 7 ı Motor shaft shown page 7 ˆ Brush bar end caps shown page 7 Hose clip Turbo nozzle certain...

Страница 4: ...the left to decrease suction This feature is most useful when using the hose and accessories Use the minimum setting when vacuuming delicate fabrics curtains etc When not using the hose it is advisable to keep the variable slider set to maximum Using on carpets 1 Place cleaner in its upright position 2 Set the carpet height adjustment knob to the desired position 3 Release the mains cable by revol...

Страница 5: ...ge the brush bar pull away from the brush bar and dispose EMPTYING Empty the dust canister regularly even if it does not look full this will maintain the performance 1 Remove the front cover by lifting the cover release lever E 2 Lift up the dust canister release Î and pull the canister away from the main body 3 Take the canister to the dustbin 4 Turn the lid 1 4 turn anti clockwise to unlock lift...

Страница 6: ...Remove the dust canister 2 Lift out the filter and shake over a dustbin The filter may also be washed in water no detergents but must be totally dry before re fitting 3 Replace the filter Exhaust filter I The exhaust filter is located below the dust canister compartment 1 Remove the front cover 2 Remove the exhaust filter Ú by pulling forward at the top and lift it away 3 Take the filter out of th...

Страница 7: ...r of its location on the brush Refitting floor nozzle base cover M 15 Hook the base cover into the front of the floor nozzle ensuring all four hooks are engaged M 16 Rotating the cover downwards and rearwards slowly close the cover 17 Tighten three fixings using screwdriver to turn fixings a quarter of a turn to the lock position Note If the cover will not fully close or fixings will not lock lift...

Страница 8: ...n seven working days of receipt If for any reason this item is replaced during the 2 year guarantee period the guarantee on the new item will be calculated from original purchase date Therefore it is vital to retain your original receipt or invoice to indicate the date of initial purchase To qualify for the two year guarantee the appliance must have been used according to the manufacturers instruc...

Отзывы: