2. PACKAGING, STORAGE, HANDLING AND TRANSPORT
2.1 PACKAGING
The AIR series vacuum pumps are provided without packaging. Packaging, such as wooden
crates, can be requested for air or sea transport.
2.2 STORAGE
For correct storage, the vacuum pump must be stored:
indoor, protected from weather conditions;
in horizontal position, resting on 4 feet.
The vacuum pumps are lubricated, during test, at our plant, with a specific oil which
ensures lubrication of inner components for approx. 6 months. In case of storage, we
recommend to clean the inside of the pump with diesel fuel (or kerosene) and oil (as
indicated in this manual).
2.3 HANDLING AND TRANSPORT
Weight of the vacuum pump: (see annexed Technical Specifications).
The vacuum pump must be:
1. Slung by metal hooks to be inserted into the eyebolt, or sling.
2. Lifted by forklift (if on pallet), bridge crane, crane.
The vacuum pump is provided, as standard, with protection compliant with EC directives, which
must be fitted by the installer using the screws provided.
3. ASSEMBLY, INSTALLATION, DISASSEMBLY, REASSEMBLY
During maintenance, inspection, use and repair, we recommend the use of
personal protection devices listed at the beginning of the manual.