Operation
The TriStar MPPT 150V provides seven (7) standard battery charging settings that are selectable
with the settings DIP switches (see Figure 4.1 above). These standard charging settings are
suitable for lead-acid batteries ranging from sealed (gel, AGM, maintenance-free) to Flooded and
L-16 cells. In addition, an 8th charging setting provides for custom set-points using MSView
TM
PC
software.
Shared Settings
Value
Units
Absorption Extension Voltage
12.50
Volts
Absorption Extension Time
Absorption Time + 30
minutes
Float Exit Timeout
60
minutes
Float Cancel Voltage
12.30
Volts
Equalize Timeout
Equalize Time + 60
minutes
7HPSHUDWXUH&RPSHQVDWLRQ&RHI¿FLHQW
- 5
millivolts /
°C / cell
* 25°C reference
Table 4-2. Battery settings that are shared between all battery types
The shared settings in Table 4-2 above are common to all battery types. The following
illustrations graphically explain the shared settings.
Absorption Extension
1:00
2:00
3:00
4:00
5:00
6:00
12.50 V
B
u
l
k
E
x
ten
d
e
d
Absor
p
tion
Flo
a
t
Absor
p
tion
Absorption Extension Voltage
time (hrs)
)LJXUH$EVRUSWLRQH[WHQVLRQFKDUJLQJSUR¿OH
If battery voltage discharges below 12.50 Volts (25.00 Volts @ 24 V, 50 Volts @ 48 V) the
SUHYLRXVQLJKW$EVRUSWLRQFKDUJLQJZLOOEHH[WHQGHGRQWKHQH[WFKDUJHF\FOHDVVKRZQLQ¿JXUH
4-3 above. 30 minutes will be added to the normal Absorption duration.