RatiNgS (all 12 V)  

SHS 6 

 

• 100 Watts or 6 Amps for Solar and Load

SHS 10

   

• 170 Watts or 10 Amps for Solar and Load

NOtES:   

 For use with solar panels only.

tEcHNicaL iNFORmatiON

• Regulation Point

   

14.3 Volts

• Low voltage Disconnect

 

11.5 Volts

• Low voltage Reconnect

 

12.6 Volts

• Type of Charging   

Series PWM

 

 

 

 4 Stage: Bulk, PWM, Boost and Float. 

Temperature compensated charging

• Electronic Protections

 

  Short circuit and overcurrent—

   solar and load 

Reverse polarity—solar, load,battery. 

Reverse current at night 

Limits high voltage to protect loads 

Lightning protection

• Tropicalization

 

  

Conformal coated printed 

  

 circuit board 

 

Corrosion resistant terminals

• Terminals

 

 

For wire sizes to 4 mm

2

• Dimensions

 

 

15.1 x 6.6 x 3.6 cm

• Weight

   

 

113 g

• Self-consumption

   

8 mA maximum

• Temperature

 

 

–25°C to +50°C

• Humidity

 

 

100% non-condensing

• Enclosure

 

 

IP 22

• Warranty

 

 

2 years

• Compliance

 

 

CE, World Bank

En

g

lis

h

SHS

TM

 

SOLAR CONTROLLER

+

SOLAR

+

BATTERY

+

LOAD

4

3

2

1

6

5

4

3

2

1

6

5

NORmaL 

Start-Up

all ON means PROBLEm

•  + and – wires touch or  

too  many amps

1

iNStaLLatiON

• Connect wires in order 

indicated 1 - 6

• Use with lead-acid         

batteries only

• Use with 12V systems only

• Do not exceed Solar and 

Load ratings (6A or 10A), 
depending on version

LigHtS

G         Green ON

 when solar is charging battery

G         Green ON

 

when battery level full

Y          Yellow ON

 

when battery level medium

R          Red BLINK 

when battery level low

R          Red ON

 

when loads cut off

G

 

                   

Green ON then

                    

Yellow ON then

R

                     

Red ON

G     Green ON

Y      Yellow ON

R      Red ON

To correct problem:

1. Check wires

2. Reduce amps if needed

3. Reset controller

• Disconnect b

• Reconnect b

SHS Night Light models
SHS-NL-6 / SHS-NL-10:

The load turns ON at dusk and 

turns OFF at dawn. The load 

does NOT turn on during the 

day. 