Page 32
CREASING
Section 11 Trouble Shooting
Fault
Reason
Solution
Erratic register of
Damaged roller surface
Replace rubber rollers
the Creaser
Check Gap Setting
Reset & tighten to ensure rollers are driving card.
Faulty Drive motor
Remove and replace motor assembly.
No Power
Fuse Blown
Replace with correct value.
or No Display
Check Power supply input on
Check cables for continuity to
Emergency stop button.
Faulty wire or connection.
Check power supply output
Black lead of meter to Black wire.
Voltage on CN2=5V dc
R
Voltages should read 240V or 110V AC
Replace
ed lead of meter to Red wire.
Voltage on CN2=24V dc
Red lead of meter to Yellow wire.
If supply has input but no output
Replace PSU.
Check voltage on main
If no voltage then check for damaged
PCB CN6 Brown and Blue
wire or connection. Replace as required.
No Drive or Motors Pulsing Low or No Power to Motors Check green light is illuminated on both PSUs
Check 240/110V AC input to Large PSUs
( Meter across L & N terminals)
No LED on Stepper PCB
Low or No Power from PSU Meter across V+ & V- of SP-150-24 reading 24V dc
Meter across V+ & V- of SP-150-48 reading 48V dc
Replace PSU if no or low reading
Meter across V+ of SP-150-48 & V- of SP-150-24 reading 72V dc
If voltage is correct but no light on stepper then check cable integrity.