Installation
1.
Put the meter into a wall box and connect the AC power wire L,N to
iZ2EM
connector L, N.
2.
The black wire of current sensor, CT1 or CT2, should connected to the negative
terminal of
iZ2EM
,CT1- or CT2-. Another wire should connected to the plus
terminal of
iZ2EM
,CT1+ or CT1+.
3.
There is a clasp on the side of the current sensor, it can lock or unlock the clamp.
It is convenient to circle the already connected cable.
Troubleshooting
Cause of Failure
Recommendation
Symptom
The meter is not working
and LED off
1. The meter is not
connect to the Main
power
2. The meter break down
1. Check power connections
2. Don’t open up the meter and send it
for repair.
The meter cannot report to
the group
1. Not carry out
association
2. Same frequency
interference
1. Carry out association
2. Wait for a while to re-try
Specification
Operating Voltage
Rated Primary Current
Range
Operating Temperature
Frequency Range
100~240VAC
0.05A~60A x 2 Channel ; Split Core Transformer
Minimum 40 m in door 100m outdoor line of sight
0°C ~ 40°C
iZ2EM
-1 868.40 & 869.85MHz (EU) /
iZ2EM
-2 908.40 & 916.0MHz(USA/Canada) /
iZ2EM
-3 922~927MHz (Taiwan/JP)
** Specifications are subject to change and improvement without notice.
DANGER
Danger of electrocution!
All works on the device may be performed only by a qualified and licensed electrician.
Observe national regulations.
Any works introducing changes into the configuration must be always performed with
disconnected voltage.
www.mordomus.com