iThink – Management Unit
Hardware: V1
Firmware: V1
Open-Collector Outputs Connections:
The 8 Outputs Open Collector bus can be used using the
iRM8 module, connected according to Image 2a or with one
or several direct relays according to Image 2b.
Digital Inputs Connections:
Keys must be connected in parallel, sensors with normally
closed contact (N.C.) must be connected in series, sensors
with normally open contact (N.O.) must be connected in
parallel, Image 2b,
when there is no more than one.
The counters can only be connected to the terminals (2 and
3).
12VDC Power Supply Connections:
It is recommended to use
iPSE156
power supply provided
with the iThink module. This should be connected to the DC
IN of the iThink module.
The power supply dedicated to the iThink module
must be
supported by UPS.
Touch Screen Interface Connection:
The iThink module provides an Output VGA (SubD 15Pin)
and an RS232 (SubD 9Pin) port for connecting the video port
and touch communication with the touch monitor (LP-15).
LAN Network Connection:
The iThink module provides a LAN communications port for
connecting the Mordomus system to the home network and
the internet. This port should be connected to a port on the
Network Router/Switch. To configure it, you must, after
connecting to the LAN, access the operating system of the
iThink module and make the network settings, see Image 1.
WLAN Network Connection:
The iThink module provides a WLAN communications port for
connecting the Mordomus system to the home network and
the internet through a wireless connection. To configure it,
you must access the operating system of the iThink module
and perform the wireless network settings.
SIM Card Connection:
If your iThink module provides GSM, the SIM card must be
inserted before powering up.
6.
FUNCTIONING:
LEDs code:
Orange LED intermittent:
The GSM module is connected to
the network;
Red LED blinking:
Status RX, sending data from MDiBus;
Green LED blinking:
Status RX, receiving data from MDiBus;
Green LED ON and Red LED blinking
: Updating process in
course;
Red LED ON:
Module have no address.
12VDC Power Supply Interruption:
After an interruption of the 12VDC power supply, the iThink
module will perform a full system restart.
The resetting of the module implies that the module is
switched off and when it is switched on it resets all its
previous state.
* To check for a more current version of the manual please go to
Manual: iThink-1827-EN
Pág.
2
/
2
Image 2a
Image 2b