19
INSTALLER
Ensure that the pipe sizing and connections between the supply/bottle regulator
and the caravan/vehicle is designed so that no more than a maximum pressure
drop of 2.5mbar occurs.
The complete installation must be tested for gas soundness.
12.8- WATER SUPPLY
A cold water supply with a working pressure of a minimum of 0.25 bar,
measured at the cold water inlet to the heater is required.
Wherever possible the cold supply to the heater should be the first connection off
the main supply, in order to minimise hot water flow reduction when cold water
services are called for.
13.- INSTALL ATION INSTRUCTIONS
13.1- PACKAGING
The water heater is supplied in separate packaging:
– Water heater and hanging bracket
– Flue kit supplied separately
– Gas and water connections supplied separately
13.2- SELECTING THE POSITION
Decide where the heater is to be fixed taking into account the installation
requirements in section 12 and the dimensions given in section11.
13.3- REMOVING THE COVER
Remove the gas knobs and the water temperature dial knob.
Remove the screw holding the cover in place. This is on the front of the cover,
behind the gas knob.
Take the cover off by removing the over-centre hinge clips at the top.
13.4- WALL MOUNTING
Screw the bracket to the wall and hang the heater. A further screw fixing should
be made through the chassis rail at the bottom to the wall to secure the heater
during transport or road use.
13.5- WIRING
Observe all the usual precautions to ensure that the electricity supply is isolated
before beginning any installation work. The heater should be wired as described
in section 12.6
Important: this appliance must be earthed.
1-10.010.649-ingles:1-10.005.856-ingles 24/03/14 17:42 Página 19