13
INSTALLER
Certification, Category and Type:
MODEL F-11 E L
EC Type test certificate
99CN922
Category
I
2E+
I
2h
I
3+
I
38/P
Country of destination
BE, FR
ES, GB, IE, IT, PT
BE, ES, FR, GB, IE, IT, PT
NL
Type
C
12
Degree of electrical protecction
IP-44
Symbol
Units
Model F-11E L
Power an energy consumption
Nominal output power
Pn
Kw
19,2
Minimun output power
Pmin
Kw
8,4
Power modulation range
Pmin - Pn
Kw
8,4-19,2
Nominal energy consumption
Qn
Kw
22,1
Minimun energy consumption
Qmin
Kw
9,8
Gas Data
2 H
Natural G20
mbar
20
2 E+
Natural G20/G25
mbar
20-25
Connection pressure
3 +
Butane G30
mbar
28-30
Propane G31
mbar
37
3 B/P
Butane G30
mbar
30
2 H/2 E+
Natural G20 Hi=9,45 Kwh/m3
m3/h
2,34
Gas consumption
Natural G25 Hi=8,13 h/m3
m3/h
2,32
3+/(3B/P) Butane G30 Hi=12,68 Kwh/kg
Kg/h
1,74
Propane G31 Hi=12,87 Kwh/kg
Kg/h
1,72
2 H/2 E+
Natural G20
mbar
12,7
Burner pressure at
Natural G25
mbar
16
nominal power
3+/(3B/P) Butane G30
mbar
27
Propane G31
mbar
33,5
2H/2E+
Natural G20
m3/h
23,06
Air Flow needed for
Natural G25
m3/h
23,37
the combustion
3+/(3B/P) Butane G30
kg/h
20,19
Propane G31
kg/h
20,27
Water data
Water flow
∆
50º C
l/min
2,-5,5
∆
25º C
l/min
3,7-11
Max operating pressure
MPa (bar)
1,3 (13)
Min operating pressure
Max. tp selector
MPa (bar)
0,015 (0,15)
Min. tp. selector
MPa (bar)
0,025 (0,25)
Combustion products
Flow
g/s
15,2
Temperature
ºC
160
Electrical Data
Electrical supply
V/Hz
220-230V-50 Hz
Maximun absorbed power
W
35
Connector dimensions and pipe diameters
Gas inlet
Natural
3/4 “
Connections /inner Ø (mm)
Butane - Propane
3/4 “
Cold Water Inlet
3/8 “
Hot Water Outlet
1/2 “
Flue outlet (mm)
Ø 60-100
8.- TECHNIC AL CHARACTERISTICS
1-10.010.649-ingles:1-10.005.856-ingles 24/03/14 17:42 Página 13