Introduction

Moore Industries’ FCT [UB] Signal Converter/
Isolator takes in either current or voltage input and
provides isolated current or voltage output.

This manual contains the information necessary to
calibrate, install, operate, maintain, and trouble-
shoot the FCT [UB].  It includes a brief unit
description, a table of performance and operational
specifications, and an explanation of Moore
Industries’ model/serial number-based product data
tracking system.

The following guidelines are used throughout the
manual:

• A “

Note”  provides information to help you in

avoiding minor inconveniences during
calibration, installation, or operation.

• A “

Caution

” provides information on steps to

take to avoid procedures and practices that
could risk damage to the FCT [UB] or other
equipment.

• A “

WARNING

” provides information on steps

to take to avoid procedures and practices that
could pose safety risks to personnel.

Description

The FCT [UB] is a compact, versatile device,
featuring universal powering, and user-set zero and
span potentiometers.

Universal Power Input

 signifies that the FCT [UB]

can be powered either by alternating or direct
current.  The standard unit accepts from 90-260Vac
and from 22-300Vdc power.  No field configuration
is required.

Complete Input/Output/Power isolation

 stops

ground loops up to 1000Vrms.

UB Housing 

with U-back mounting bracket for

surface mounting.

Содержание FCT [UB]

Страница 1: ...FCT UB Page 1 The Interface Solution Experts FCT FCT UB Signal Converter Isolator April 2016 146 715 00 B Signal Converter Isolator UB SPAN ZERO FCTSIGNAL CONVERTER ISOLATOR...

Страница 2: ...Page 2 FCT UB The Interface Solution Experts Table of Contents Introduction 3 Description 3 Specifications 4 OrderingInformation 4 Calibration 5 6 Installation 7 9 Operation 8 Customer Support 8...

Страница 3: ...voiding minor inconveniences during calibration installation or operation A Caution provides information on steps to take to avoid procedures and practices that could risk damage to the FCT UB or othe...

Страница 4: ...eters Span 10 Zero 5 300 grams 0 6 lbs Performance continued Adjustments Ordering Information Input Output Unit FCT UB 0 20mA into 50 ohms 4 20mA into 50 ohms 0 50mA into 20 ohms 10 50mA into 20 ohms...

Страница 5: ...rather than in the field Use a technician s bench or a similar lab type environment Table 1 Calibration Equipment Equipment Specifications Voltage or Current Source Power Source Multimeter Ammeter or...

Страница 6: ...erclockwise minimum zero and span 15 turns then approximately 7 turns clockwise This approximates mid scale for the pots 2 Set the input source in the setup to 0 zero percent 1V for example if the FCT...

Страница 7: ...the FCT UB Moore Industries suggests that the calibration procedures be carried out to confirm that the configuration of the unit is appropriate for the intended application Costly down time will resu...

Страница 8: ...he factory for assistance Verify that all electrical connections are clean and tight Verify that the power source for the unit is supplying power at levels rated safe and appropriate according to prod...

Страница 9: ...ng the FCT UB Figure 3 Installing the FCT UB with the TX option SPAN ZERO RECEIVER VOLTAGE OR VOLTAGE TRANSMITTER VDC OR VAC POWER SOURCE IN IN OUT OUT GND PWR PWR SPAN ZERO RECEIVER 2 WIRE TRANSMITTE...

Страница 10: ...R BREACH OF ANY WARRANTY CONCERNING THE GOODS OR SERVICES SHALL BE FOR THE COMPANY AT ITS OPTION TO REPAIR OR REPLACE THE GOODS OR SERVICES OR REFUND THE PURCHASE PRICE THE COMPANY SHALL IN NO EVENT B...

Отзывы: