Flexible Sensors for Thermowell
Temperature Assemblies
Page 4
Flexible Sensors for Thermowell
Temperature Assemblies
Page 4
The WORM Sensor Kit
SEN3
Sensor Kit includes Three Complete "the WORM" Sensor Assemblies plus Spare Assembly Parts
SEN1
Sensor Kit includes One Complete "the WORM" Sensor Assembly plus Spare Assembly Parts
SEN
Sensor Only; with Wire Jacket and Spring
Jacket and Spring Length
(See Page 2 to Determine Total Sensor Insertion Length)
CL24
24-Inch Wire Jacket and Spring Length plus 6-8" lead wires (specify for total sensor insertion lengths of 22-inches and under)
CL36
36-Inch Wire Jacket and Spring Length plus 6-8" lead wires (specify for total sensor insertion lengths of 22-inches to 34-inches)
CL?
Special Wire Jacket and Spring Length plus 6-8" lead wires - Replace "?" with length up to 120" (Specify in 0.25-inch increments)
Sensor Sheath Diameter
D25
Appropriate for 0.25-inch and 6mm diameter applications
D18
0.18-inch diameter applications for single elements (WS); for (WH), consult the factory
Sensor Sheath Material
S316
Stainless Steel 316; specify for measurements up to 760°C (1400°F)
INC
Inconel (WHTCKG or WHTCKU sensor types only) up to 1,093°C (2,000°F) only
Sensor Type
(see
Sensor Specifications
on next page; consult factory for special WORM sensors)
RTD SENSORS:
WSPT14
Standard Platinum RTD; 4-Wire; 100 ohm
;
alpha = 0.00385
WS2PT14
Standard Platinum RTD; 4-Wire; 100 ohm (Dual Sensor); alpha = 0.00385
WSPT104
Standard Platinum RTD; 4-Wire; 1000 ohm; alpha = 0.00385
WHPT14
High Temperature Platinum RTD; 4-Wire; 100 ohm; alpha = 0.00385
WH2PT13
High Temperature Platinum RTD; 3-Wire; 100 ohm (Dual Sensor); alpha = 0.00385
WHPT104
High Temperature Platinum RTD; 4-Wire; 1000 ohm; alpha = 0.00385
WSN4
Nickel RTD; 4-Wire; 120 ohm
WSCU4
Copper RTD; 4-Wire; 10 ohm
THERMOCOUPLE SENSORS:
WSTC?G
Standard, Replace ? with J, K, T or E Thermocouple, Grounded
WS2TC?G
Standard, Replace ? with J, K, T or E Thermocouple, Grounded (Dual Sensor)
WSTC?U
Standard, Replace ? with J, K, T or E Thermocouple, Ungrounded
WS2TC?U
Standard, Replace ? with J, K, T or E Thermocouple, Ungrounded (Dual Sensor)
WHTC?G
High Temperature, Replace ? with J, K, T or E Thermocouple, Grounded
WH2TC?G
High Temperature, Replace ? with J, K, T or E Thermocouple, Grounded (Dual Sensor)
WHTC?U
High Temperature, Replace ? with J, K, T or E Thermocouple, Ungrounded
WH2TC?U
High Temperature, Replace ? with J, K, T or E Thermocouple, Ungrounded (Dual Sensor)
Assembly Options
(not required)
-
WW
Wire Wound Option for Temperatures below -10°F or above +850°F to +1000°F
(For RTDs only)
-.04
1/3 DIN 0.04% High-Accuracy RTD Sensor
(Available on any WSPT104/WHPT104 RTD sensor types only)
-.06
Class "A" High-Accuracy RTD Sensor
(Available on any WS, WH, PT14 AND PT104 RTD sensor types only)
-10G
10G Low-intensity Vibration Sensor (See Sensor Specifications)
-30G
30G High-intensity Vibration Sensor (See Sensor Specifications)
The WORM Sensor Kit
[SEN]
Select one from each category to order a Sensor Kit:
SEN3 CL36 D25 S316 WSPT14 -.06 [SEN]
Model Number Example