Moore Industries TEMPTATION 2000 T2X Скачать руководство пользователя страница 10

www.miinet.com

Moore Industries-International, Inc.

- 10 -       

User’s Manual

235-781-00D

June 2019

T2X RTD Temperature Transmitter

T2X

Select one from each category to order:

  

Temperature Transmitter and Enclosure

        Unit                Input              Output            Power         Options                                                Housing

T2X

  

TEMPTATION 

 

2000, Non-

Isolated PC-

Programmable

 

2-Wire RTD   

 

Transmitter

PRG 

 

User  

selectable 

with PC 

Configuration 

Software 

4-20MA 

User  

scaleable  

with PC 

 

Configuration 

Software

8-30DC 

for 

Intrinsically-

Safe

8-42DC 

 

 

-ISC  

(Intrinsically-

Safe, CSA)

-ISE  

(Intrinsically-

Safe, ATEX/

LCIE)

 

-ISF 

(Intrinsically-

Safe, FM 

Approvals)

HPP 

Hockey-puck housing for mounting in standard connection heads 

LH1NS‡

 Connection head (FM approved, NEMA 4X, IP66) with two entry 

ports: ½-inch NPT cable and process–black PBT polyester cover

 

LH1MS‡

 Connection head (FM approved, NEMA 4X, IP66) with two entry 

ports: M20 cable and ½-inch NPT process–black PBT polyester cover 

NEMA 4X, IP66 connection head with one M20 entry port and one G½ 

(BSP) entry port (aluminum body with VALOX 357U cover)

 

LH1CS‡

 Connection head with two entry ports: M20 cable and G½ (BSP) 

process–black PBT polyester cover

LH1NX

 Connection head with ½-inch NPT entry and mounting plate for 

 

customer’s air duct opening–black PBT polyester cover

LH2NS*

Explosion-proof connection head with two entry ports: ½-inch NPT 

cable and process–black metal cover

LH2MS*

Explosion-proof connection head with two entry ports: M20 cable 

and ½-inch NPT process–black metal cover

 

NOTE: 

 

*A suffix with LH2 indicates ANZEx/TestSafe (Ex d) Flameproof approval; 2”pipe-mount kit 

 

 included (i.e., LH2MSA)

 

*E suffix with LH2 denotes ATEX Flameproof enclosure; 2” pipe-mount kit included (i.e., LH2MSE)

 

*

P suffix indicates enclosure is equipped with 2” pipe-mount hardware kit (i.e., LH1NSP)

Model Number Example:

  

T2X / PRG / 4-20MA / 8-42DC [HPP]

*  Transmitter will measure ranges outside of the Conformance Range with some degradation to accuracy ratings.  Consult the factory for details.

-200 to 850°C (-328 to 1562°F)

 

 

-200 to 300°C (-328 to 572°F)

 

 

-100 to 650°C (-148 to 1202°F)

 

 

-100 to 300°C (-148 to 572°F)

 

 

-200 to 510°C (-328 to 950°F)

 

 

-80 to 320°C (-112 to 608°F)

 

 

-50 to 250°C (-58 to 482°F)

 

 

0-2200

-240 to 960°C (-400 to 1760°F)

 

 

-240 to 300°C (-400 to 572°F)

 

 

-150 to 720°C (-238 to 1328°F)

 

 

-150 to 300°C (-238 to 572°F)

 

 

-240 to 580°C (-400 to 1076°F)

 

 

-100 to 360°C (-148 to 680°F)

 

 

-203.19 to 300.53°C (-333.74 to 572.95°F)

 

 

0-2200

Conformance Range

Minimum Span

Maximum Range*

10°C (18°F)

 

 

 

 

 
 

10°C (18°F)

 

 

100°C(180°F)

 

 

30

Platinum

 

 

 

 

Nickel 

 

Copper

 

 

Resistance

 

Potentiometer

100, 200, 

 

300, 400, 500

 

 

1000 

 

100, 200, 

 

400, 500 

 

 

1000 

 

 

100 

 

120 

 

9.035 

 

0-2200

 

RTD 

2-Wire 

3-Wire  

4-Wire

0.003850

  

0.003902

0.003916

0.00672 

 

0.00427

N/A

Input Types and Ranges

α 

Input

Type

Содержание TEMPTATION 2000 T2X

Страница 1: ...e m a n d M o o r e R e l i a b i l i t y All product names are registered trademarks of their respective companies User s Manual T2X Temptation 2000 T2X RTD Temperature Transmitter No 235 781 00D Jun...

Страница 2: ...the original sale www miinet com Demand Moore Reliability Locations World Headquarters Europe Australia 16650 Schoenborn Street North Hills California 91343 6196 U S A Tel 818 894 7111 Fax 818 891 28...

Страница 3: ...re or condition that could injure the operator Qualified Personnel The Moore Industries product systems described in this manual may be operated only by personnel qualified for the specific task in ac...

Страница 4: ...ng the T2X 6 Managing Configuration Files 7 Specifications 9 Accessories 9 Ordering Information 10 Installing and Connecting the T2X 11 Physical Instructions for Installing an Encapsulated Hockey Puck...

Страница 5: ...e necessary equipment as listed in Table 1 installing the T2X PC Configuration Program onto your computer then connecting the T2X as shown in Figure 1 It is necessary to connect the T2X to the PC befo...

Страница 6: ...T2X in the form of a configuration file Pages 7 8 of the manual contains all of the instructions for configuring the T2X Use Figure 2 to find the portion of the screen that you have a question about...

Страница 7: ...o be saved and click Save Answer Yes to the dialogue box that pops up to finish saving the file Retrieving a Configuration File from Disk To retrieve a file click on the File button Use the display on...

Страница 8: ...le its 4 20mA output to offset the performance or calibration of other instruments in the process loop To scale the output enter the desired Output Zero value in the Zero Scale Output box or use the s...

Страница 9: ...ohms Recommended 35 ohms per wire for three wire inputs 5 ohms per wire for 10 ohm Cu inputs Damping 0 5 seconds user selectable Ambient Tem perature Operating Storage Range 40 C to 85 C 40 F to 185 F...

Страница 10: ...ter cover LH2NS Explosion proof connection head with two entry ports inch NPT cable and process black metal cover LH2MS Explosion proof connection head with two entry ports M20 cable and inch NPT proc...

Страница 11: ...that best suits your application 2 WIRE RTD or DECADE RESISTANCE BOX PS 2 3 4 1 PS POWER SOURCE 8 42Vdc CURRENT DRIVEN INSTRUMENT 3 WIRE RTD OR DECADE RESISTANCE BOX 4 WIRE RTD OR DECADE RESISTANCE BO...

Страница 12: ...ocess Instrumentation Industry For 2 wire transmitters certified and intended to be operated as either Intrinsically Safe Non Incendive Class I Div 2 or Type N the power parameters are clearly stated...

Страница 13: ...ng the cap clockwise Secure lock the cap by rotating the locking screw counterclockwise 4 Connect a ground wire between the ground screw on the LH2 enclosure to an appropriate earth ground Figure 4 In...

Страница 14: ...to the receiving device see Note below Note Some of Moore Industries instruments can be classified as receivers IPT2 IPX2 etc and some can be classified as transmitters TRX TRY etc while some are both...

Страница 15: ...ature Transmitter T2X This secti Locations Maximum 300uA an on contains im s m operating pa d 240uW mportant info arameters of t rmation regar the COM po rding installat ort for use in N tion of the T...

Страница 16: ...D T6 Ta 60 C The T2X shall be installed in an enclosure meeting the requirements of ANSI ISA S82 02 01 or other applicable ordinary location standards No connections shall be made to the communicatio...

Страница 17: ...Parameters can be found in Control Drawing 100 100 38 Non Incendive Applications Class I Division 2 Groups A D T6 Ta 60 C The model T2X is of open type unit Certified as a component for use only in o...

Страница 18: ...www miinet com Moore Industries International Inc 18 User s Manual 235 781 00D June 2019 T2X RTD Temperature Transmitter T2X...

Страница 19: ...No modifications are permitted without the notification and approval of the Q A Certification Engineer related dwgs or the Certifying Agency schedule dwgs 2 250 MODEL SERIAL TAG 1866A 2 S Class II II...

Страница 20: ...This is a controlled Related or Schedule drawing No modifications are permitted without the notification and approval of the Q A Certification Engineer related dwgs or the Certifying Agency schedule...

Страница 21: ...NOTICE RE PROPRIETARY INFORMATION This drawing and the information contained herein are the proprietary property of Moore Industries International Inc MIi and should not be reproduced or disclosed to...

Страница 22: ...l or workmanship This policy extends to the original Buyer only and not to Buyer s customers or the users of Buyer s products unless Buyer is an engineering contractor in which case the policy shall e...

Отзывы: