TSM24S/Q Hardware Manual

+86-400-820-9661

1.3  Safety Instructions

Only qualified personnel should transport, assemble, install, operate, or maintain this equipment. 

Properly qualified personnel are persons who are familiar with the transport, assembly, installation, 

operation, and maintenance of motors, and who meet the appropriate qualifications for their jobs. 

To minimize the risk of potential safety problems, all applicable local and national codes regulating 

the installation and operation of equipment should be followed. These codes may vary from area 

to area and it is the responsibility of the operating personnel to determine which codes should be 

followed, and to verify that the equipment, installation, and operation are in compliance with the 

latest revision of these codes.

Equipment damage or serious injury to personnel can result from the failure to follow all applicable 

codes and standards. MOONS’ does not guarantee the products described in this publication 

are suitable for a particular application, nor do they assume any responsibility for product design, 

installation, or operation.

• 

Read all available documentation before assembly and operation. Incorrect handling of the 

products referenced in this manual can result in injury and damage to persons and machinery. 

All technical information concerning the installation requirements must be strictly adhered to.

• 

It is vital to ensure that all system components are connected to earth ground. Electrical safety 

is impossible without a low-resistance earth connection.

• 

This product contains electrostatically sensitive components that can be damaged by incorrect 

handling. Follow qualified anti-static procedures before touching the product. 

• 

During operation keep all covers and cabinet doors shut to avoid any hazards that could 

possibly cause severe damage to the product or personal health.

• 

During operation, the product may have components that are live or have hot surfaces. 

• 

Never plug in or unplug the Integrated Motor while the system is live. The possibility of electric 

arcing can cause damage.

Be alert to the potential for personal injury. Follow recommended precautions and safe operating 

practices emphasized with alert symbols. Safety notices in this manual provide important 

information. Read and be familiar with these instructions before attempting installation, operation, 

or maintenance. The purpose of this section is to alert users to the possible safety hazards 

associated with this equipment and the precautions necessary to reduce the risk of personal injury 

and damage to equipment. Failure to observe these precautions could result in serious bodily 

injury, damage to the equipment, or operational difficulty.

Содержание TSM24S/Q

Страница 1: ...TSM24S Q Integrated Step Servo Motor Hardware Manual Rev 1 0 AMP MOONS Automation...

Страница 2: ...Supply 10 3 2 Connecting the TSM24S Q Communications 11 3 2 1 Connecting to the PC using RS 232 11 3 2 2 Connecting to a Host using RS 485 12 3 3 Inputs and Outputs 14 3 3 1 Connector Pin Diagram 14 3...

Страница 3: ...ntrol Digital input Control Velocity Analog velocity SCL Commanded Velocity Jogging Position Control Digital Signal type Step Direction CW CCW pulse A B Quadrature Analog Position Serial Commanded Pos...

Страница 4: ...0 VDC External Power Supply Voltage Temp Detect Over Current Detect motor encoder 5 Volt DC Power Supply DSP Driver Controller 3 3VDC Internal Logic Supply TSM24S Q I O Connector 5VDC 100mA max GND St...

Страница 5: ...in injury and damage to persons and machinery All technical information concerning the installation requirements must be strictly adhered to It is vital to ensure that all system components are connec...

Страница 6: ...e drive to the PC using the programming cable When using RS 485 it must be setup in a 4 Wire configuration see Connecting to a host using RS 485 below Connect the drive to the power supply See instruc...

Страница 7: ...reliable operation Absolute minimum power supply input is 10 VDC If the Input supply drops below 10 VDC the low voltage alarm will be triggered This will not fault the drive Absolute maximum power su...

Страница 8: ...the less current will be required from the power supply It is important to note that the current draw is significantly different at higher speeds depending on the torque load to the motor Estimating h...

Страница 9: ...3 TSM24S Q Hardware Manual 86 400 820 9661 0 0 5 1 1 5 2 2 5 3 3 5 4 4 5 5 0 0 5 1 1 5 2 2 5 3 3 5 0 10 20 30 40 50 Torque N m Speed RPS TSM24 3 G 70V Power Amps Continuous Torque Boost Supply Current...

Страница 10: ...open the internal fuse on the drive and void the warranty MOONS offers two matched power supplies for use with the TSM24S Q A 24VDC 150W P N MF150A24AG V and a 48VDC 320W P N MF320A48AG V These power...

Страница 11: ...both of these serial communication types to a PC 3 2 1 Connecting to the PC using RS 232 Locate the TSM24S Q within 1 5 meters of the PC Plug the DB9 connector of the communication cable that came wi...

Страница 12: ...eparate transmit and receive wires One pair of wires must connect the host s transmit signals to each drive s RX and RX terminals The other pair connects the drive s TX and TX terminals to the host s...

Страница 13: ...will need to connect individually to the host computer so that it can be assigned a unique address Once the drive has been connected to the PC as described above launch the Step Servo Quick Tuner sof...

Страница 14: ...being used for the Step Direction function these inputs can be used for CW CCW step start stop direction oscillator mode or general purpose input X3 X4 are low speed software programmable input and ca...

Страница 15: ...ed to Sensor FS Seek Home SH and other SCL or Q commands The diagrams below show how to connect the STEP DIR Inputs to various commonly used devices 5v to 24v out DIR STEP DIR DIR STEP STEP Indexer wi...

Страница 16: ...or mechanical switches you will need a 5 24 V power supply What is COM Common is an electronics term for an electrical connection to a common voltage Sometimes common means the same thing as ground b...

Страница 17: ...re to set the signal range offset dead band and filter frequency The TSM24S Q provides a 5 volt 100mA limit voltage supply that can be used to power external devices such as potentiometers It is not t...

Страница 18: ...is in position dynamic Y3 can be set to control a motor brake These outputs can also be turned on and off by program instructions like Set Output SO The output can be used to drive LEDs relays and th...

Страница 19: ...e an output frequency proportional to motor speed tach signal or to provide a timing output 50 pulses rev or to indicate whether the motor is in position static Diagrams of various connection types fo...

Страница 20: ...his and which warnings may be masked Code Error Solid green no alarm motor disabled Flashing green no alarm motor enabled 1 red 1 green motor stall optional encoder only 2 red 1 green ccw limit 2 red...

Страница 21: ...S Q Hardware Manual 86 400 820 9661 5 Reference Materials 5 1 Mechanical Outlines 9 5 Flat 8 58 1 38 1 20 24 129 1 1 90 77 47 14 60 5 Max 47 14 60 5 Max 4 4 5 50 9 10 1 5 Unit mm Model Length L Length...

Страница 22: ...djustable bandwidth digital noise rejection filter on all inputs X1 X2 Optically isolated 5 24 volt Minimum pulse width 250 ns Maximum pulse frequency 2 MHz Function Pulse Direction CW CCW Pulse A B q...

Страница 23: ...0 9661 8 3 Torque Speed Curves Note all torque curves were measured at 20 000 steps rev Note 5 amp rating is continuous 7 5 amp rating is boost 0 0 5 1 1 5 2 2 5 3 3 5 0 10 20 30 40 50 Continuous Boos...

Страница 24: ...software which drive is connected and what the firmware version is There are two types of SCL commands buffered and immediate Buffered commands are loaded into and then executed out of the drive s com...

Страница 25: ...e that will adjust a drive s serial communications protocol to best fit an application Typically this command is used when configuring a drive and saved as part of the startup parameters But it can be...

Страница 26: ...Beijing Branch Office Room 202 Unit 2 7th Building Huilongsen International Science Technology Industry Park No 99 Kechuang 14th Street Beijing 101111 P R China Tel 86 0 10 59755578 Fax 86 0 10 597555...

Отзывы: