32
Rev. 1.1
0004102014
SS03/05/10-S/Q/C Hardware Manual
400-820-9661
5.3 Assigning RS-485 Address
For the RS-485 drive,the dot point of LED2 indicates the communication address range is 0~15
when it is off. When the dot point of LED2 is on ,it indicates the communication address range is
16~31.
Low 4 bit(0~15) is set by the rotary switch. Use the Step-Servo Quick tuner to set the upper 1
bit (Axis 16-31). The RS-485 communication address can be set by the rotary and software on-
OLQH/('ZLOOÀDVKDERXWVHFRQGVWRGLVSOD\WKHQHZEXVDGGUHVV
RS-485 Address and LED Display
LOW/HIGH Select
Rotary Switch
Address
LED Display
Low(Axis 0~ 15)
0
0
0
1
1
1
2
2
2
3
3
3
4
4
4
5
5
5
6
6
6
7
7
7
8
8
8
9
9
9
A
:
A
B
;
b
C
<
C
D
=
d
E
>
E
F
?
F
High(Axis 16 ~ 31)
0
@
0.
1
!
1.
2
“
2.
3
#
3.
4
$
4.
5
%
5.
6
&
6.
7
‘
7.
8
(
8.
9
)
9.
A
*
A.
B
+
b.
C
,
C.
D
-
d.
E
.
E.
F
/
F.
Содержание SS03-C-C