Safety Instructions

•  Only qualified personnel should assemble, install, operate, or maintain this equipment.
•  Read all available documentation before assembly and operation.
•  It is vital to ensure that all system components are connected to earth ground.
•  This product contains electrostatically sensitive components that can be damaged by incorrect 

handling.

Selection 

Switches

Many operational 

parameters of the 

SRAC8 can be set or 

changed by position 

switches - either by 

a single switch or a 

combination of ON/

OFF settings of 2 or 

more switches.

 

SW1 

SW2 

SW3 

SW4 

SW5 

SW6 

SW7 

SW8 

Running Current

           

Microstepping

           

 

 

SW9 

SW10 

SW11 

SW12 

SW13 

SW14 

SW15 

SW16 

Idle Current

Anti Resonance

               

 

Step Input Mode

Step Input Signal Filter

Self Test

Smoothing Filter

Microstepping - 4 switches for a total of 16 settings:

Microstep(step/rev)

SW1

SW2

SW3

SW4

200

ON

ON

ON

ON

400

OFF

ON

ON

ON

800

ON

OFF

ON

ON

1600

OFF

OFF

ON

ON

3200

ON

ON

OFF

ON

6400

OFF

ON

OFF

ON

12800

ON

OFF

OFF

ON

25600

OFF

OFF

OFF

ON

1000

ON

ON

ON

OFF

2000

OFF

ON

ON

OFF

4000

ON

OFF

ON

OFF

5000

OFF

OFF

ON

OFF

8000

ON

ON

OFF

OFF

10000

OFF

ON

OFF

OFF

20000

ON

OFF

OFF

OFF

25000

OFF

OFF

OFF

OFF

Idle Current - 2 switches for a total of 4 settings:

Idle

SW9

SW10

25%

ON

ON

50%

OFF

ON

70%

ON

OFF

90%

OFF

OFF

Step Input Mode (

SW13

) -  OFF for Step and 

Direction input, ON for CW/CCW input
Step Smoothing Filter (

SW15

) - ON to enable, OFF to 

disable

Running current - 4 switches for a total of 16 settings:

Current(Peak)

SW5

SW6

SW7

SW8

0.4A

ON

ON

ON

ON

0.6A

OFF

ON

ON

ON

0.9A

ON

OFF

ON

ON

1.2A

OFF

OFF

ON

ON

1.5A

ON

ON

OFF

ON

2.0A

OFF

ON

OFF

ON

2.5A

ON

OFF

OFF

ON

3.0A

OFF

OFF

OFF

ON

3.5A

ON

ON

ON

OFF

4.0A

OFF

ON

ON

OFF

4.5A

ON

OFF

ON

OFF

5.2A

OFF

OFF

ON

OFF

5.9A

ON

ON

OFF

OFF

6.6A

OFF

ON

OFF

OFF

7.3A

ON

OFF

OFF

OFF

8.0A

OFF

OFF

OFF

OFF       

Anti-Resonance - 2 switches for a total of 4 settings:

Option

SW11

SW12

Inertia

0

ON

ON

Low

High

1

OFF

ON

2

ON

OFF

3

OFF

OFF

Step Input Signal Filter (

SW14

) - ON for 150 kHz, 

OFF for 2 MHz
Self test (

SW16

) - ON for 2 rev CW/CCW .5 rps self 

test, OFF for none