background image

Owner’s Manual 

 

 

Connecting the 400M 

 
Prior to making any connections or removing the XLR 
jumpers, the power amplifier must be turned off and 
the AC cable disconnected for at least 1 minute. 
 

1.

 

Connect the input cables running from your 
preamplifier’s outputs, whether balanced or single-
ended, to the amplifier’ s XLR or RCA input, 
respectively. We highly recommend that you use 
the balanced XLR input (provided that your 
preamplifier has balanced outputs) to take full 
advantage of 

Nēo 400M 

Mono Power Amplifier’s 

capabilities. Please refer to the next section, 
“Balanced Operation” on for further information.  

 

Do  not connect cables to both the XLR and RCA 
inputs at the same time.  Damage to both the 400M 
and the connected equipment can result that is not 
covered by warranty.  

 

      Don’t  hesitate  to  use high quality interconnect 

cables

*

. Poor quality interconnect cables can 

degrade the overall sonic performance of your 
system.  It is recommended, though not mandatory, 
to use balanced interconnects between your 
preamplifier and the 

400M 

when using long cable 

runs  (i.e. more than 3 meters in length).   

 

2.

 

Connect your speaker, with the cable of your 
choice, to the 

400M

’s

 

speaker binding posts. Take 

care to respect the polarity (“+” , “-” ) of the outputs. 
Once again, don’t hesitate to use high quality 
speaker cables

*

. Poor quality speaker cables can 

degrade the overall sonic performance of your 
system. 

3.

 

Connect the supplied AC power cable to the IEC 
receptacle, located on the amplifier’s rear panel.  
Ensure that the AC wall outlet you use has a 
functioning ground.  For the best sonic 
performance, it is preferable that you plug your 

400M

 directly into a dedicated AC outlet and avoid 

using an extension cord.  If you have the time and 
willingness, consider installing a superior quality AC 
wall outlet such as a hospital grade Hubbell

*

.

 

 

Please speak with your MOON Authorized Retailer about 

the benefits of high quality cables  for  your  system,  and     
superior quality AC wall outlet.. 

 
 

Balanced Operation  

 

When using an unbalanced interconnect, the audio 
signal runs through both the center wire and the 
shield/ground wire.  Any noise picked up by this 
interconnect  (ie. nearby magnetic fields such as an AC 
power cord) will be reproduced by the amplifier and 
heard through the loudspeakers.  Conversely, a 
balanced interconnect has three separate conductors; 
one for the ground and two for the actual signal.  These 
two signals are identical except that one is 180 degrees 
out of phase with the other.  For example, when one 
conductor is carrying a signal of +5 Volts, the other will 
be  carrying  a  signal  of  –5  Volts.    When  these  two 
inverted signals on a balanced line are input into a 
differential power amplifier such as the 

Nēo 400M

, any 

noise picked up by the interconnect will be eliminated 
since a differential circuit amplifies only the difference 
between these two signals: Noise on a balanced 

 

interconnect will be equal on both conductors and 
therefore cancel out. 

 

Содержание 400M Neo Series

Страница 1: ...400M Series Mono Power Amplifier Owner s Manual ...

Страница 2: ...400M Neo Series ...

Страница 3: ...n or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus Unplug mains cord during transportation 11 Only use attachments and accessories specified by the manufacturer 12 Use only with the cart stand tripod bracket or table specified by the manufacturer or sold with the apparatus When a cart is used use caution when moving the cart apparatus combin...

Страница 4: ...per voltage Both the shipping box and rear panel serial number label will indicate the correct voltage Use of any other voltage will likely damage the unit and void the warranty 3 AC extension cords are NOT recommended for use with this product The mains plug of the power supply cord shall remain readily accessible 4 NEVER use flammable or combustible chemicals for cleaning audio components 5 NEVE...

Страница 5: ... 7 Installation Placement 7 Rear Panel Layout 8 Connecting the Nēo 400M 9 Balanced Operation 9 Operating the Nēo 400M 10 Remote Operation 11 Specifications 12 www simaudio com Simaudio Ltd 1345 Newton Road Boucherville Québec J4B 5H2 CANADA Date Code 20150203 ...

Страница 6: ...th the goal of faithfully capturing these elusive qualities The information contained in this manual is subject to change without notice The most current version of this manual is available on our official website at http www simaudio com Your Nēo 400M Mono Power Amplifier incorporates many significant design features to achieve its world class level of performance This is an abbreviated list of t...

Страница 7: ...umber Installation Placement The Nēo 400M Mono Power Amplifier requires reasonable ventilation to maintain an optimum and consistent operating temperature especially since it will radiate heat when driven hard Consequently it should be placed in a location with empty space around it for proper heat dissipation You should never place another component on top of this integrated amplifier As well it ...

Страница 8: ...uired ONLY when using the single ended RCA input When you decide to switch to single ended input mode you must reinstall the XLR jumper between pins 1 and 3 exactly as shown below The left side of the rear panel has a pair of 12 Volt triggers each on a 1 8 mini jack one input and one output the latter for use if you need to daisy chain a second power amplifier on the same trigger circuit Immediate...

Страница 9: ... your system 3 Connect the supplied AC power cable to the IEC receptacle located on the amplifier s rear panel Ensure that the AC wall outlet you use has a functioning ground For the best sonic performance it is preferable that you plug your 400M directly into a dedicated AC outlet and avoid using an extension cord If you have the time and willingness consider installing a superior quality AC wall...

Страница 10: ...s power up your preamplifier prior to powering up your 400M As well always power down your 400M prior to powering down your preamplifier Troubleshooting Your Nēo 400M Mono Power Amplifier is equipped with a self diagnostic system that will automatically shut itself down when it detects either DC direct current or it enters into thermal protection mode due to overheating When either of these situat...

Страница 11: ...gger output on the 350P is connected to the 12V trigger input on the top 400M using a 1 8 mini jack cable The 12V trigger output from this 400M connects to the 12V trigger input on the bottom 400M also using a 1 8 mini jack cable When you turn on the 350P using a remote control or its Standby button both 400M s will turn on automatically The same rule applies when you put the 350P into Standby mod...

Страница 12: ...m Current Peak Continuous 56 amperes 26 amperes Intermodulation Distortion Unmeasureable Total Harmonic Distorition 20Hz 20kHz 1W 0 02 Total Harmonic Distorition 20Hz 20kHz 125W 0 05 Power Consumption idle 36 Watts AC Power Requirements 120V 60Hz or 240V 50Hz Shipping Weight 33 lb 15 Kg Dimensions W x H x D inches cm 16 9 x 3 5 x 14 0 42 9 x 8 9 x 35 6 Balanced Pin Assignment Pin 1 Ground Pin 2 Po...

Страница 13: ...Owner s Manual 13 ...

Страница 14: ...400M Neo Series 14 ...

Отзывы: