Gemini Software Operation
Gemini 720is Imaging Sonar
Document: 0703-SOM-00002, Issue: 7
52
© Tritech International Ltd.
5.3.2. Gemini Hub
Hubs Tab
The
Hubs
tab shows the status information from any connected Gemini Hubs.
Hub Setup Tab
The
Hub Setup
tab allows configuration of the serial ports on the rear of the Gemini Hub to
allow RS232 data to pass through to the Gemini software from external sensors.
Port
The port letter, corresponding to the label on the back of the Gemini
Hub.
Mode
Can change between an ASCII decode, binary decode or can echo
the data on one of the other ports (ASCII is the default input, only the
Simrad EM3000 uses a binary input). Echo is used as an alternative to
a serial splitter cable in systems where the sensor data is also used by
another application or device.
Sync
The sync character used to frame the ASCII string.
Baud
The baud rate of the sensor connected to the port.
Decode
The decode definition to apply for the expected receive data on the port.
Max
Set the time in seconds to generate an alarm if no data is received.
Age
The age of the data, shows when the last good data was received (see
note below).
Hz
The incoming data rate