background image

IPx4

30504-16 DE-EN-RU / 43.17

EN

Installation and operation manual

Sauna-Heizgerät mit integrierter Steuerung

Sauna heater with built-in control unit

Печь для сауны с встроенным блоком управления

 

RU

Инструкция по монтажу и эксплуатации

D

Montage- und Gebrauchsanweisung

IRON III

MONUMENTS

Содержание IRON III

Страница 1: ...on and operation manual Sauna Heizgerät mit integrierter Steuerung Sauna heater with built in control unit Печь для сауны с встроенным блоком управления RU Инструкция по монтажу и эксплуатации D Montage und Gebrauchsanweisung IRON III MONUMENTS ...

Страница 2: ...Elektroanschluss 6 Technische Daten 8 Anschlußbeispiel der Saunaanlage 9 Montage Saunaheizgerät 10 Mindestabstände 10 Inbetriebnahme 13 Sicherheitsabschaltung 15 Saunasteine 16 Wartung und Pflege 17 Recycling 19 Service Adresse 19 Allgemeine Servicebedingungen 20 ...

Страница 3: ...ein optimales Saunaklima nur dann erreichen wenn die Kabine mit ihrer Zuluft und Abluft dasSaunaheizgerätunddasSteuergerät aufeinander abgestimmt sind Beachten Sie die Angaben und Informationen Ihrer Sauna Lieferanten Die Saunaheizgeräte erwärmen Ihre Saunakabine durch aufgeheizte Konvektionsluft Dabei wird Frischluft aus der Zuluftöffnung angesaugt die durch das Erwärmen nach oben steigt Konvekti...

Страница 4: ...kt rischer Betriebsmittel mit festem Netzanschluss dürfen nur durch einen Fachmann erfolgen Hierbei sind besonders die notwendigen Schutzmaßnahmen nach VDE 0100 v 49 DA 6 und VDE 0100 Teil 703 2006 2 zu beachten Saunaheizgerät und Steuergerät dürfen nur in Saunakabinen aus geeignetem harzarmen und un behandeltem Material z B Nor dische Fichte verwendet werden In der Saunakabine darf nur ein Saunah...

Страница 5: ...enstände auf dem Saunaheiz gerät abgelegt wurden Achtung Während des Be triebes auftretende hohe Tem peraturen am Saunaheizgerät können bei Berührung zu Verbren nungen führen Das Saunaheizgerät ist nicht für den Einbau oder Aufstellung in einer Nische unter der Bank oder unter einer Dachschräge be stimmt Das Saunaheizgerät nicht bei ge schlossener Lufteintrittsöffnung in Betrieb nehmen Die Kabinen...

Страница 6: ...n gebracht werden einadrige Leitungen verwendet müssen diese durch ein bieg sames mit dem Schutzleiter ver bundenes Metallrohr geschützt werden Den Mindestquerschnitt der Anschlussleitung und die ge eignete Kabinengröße im Verhält nis zur Anschlussleistung in kW entnehmen Sie der Tabelle Bei der Montage des Saunaheiz gerätes ist darauf zu achten dass der senkrechte Abstand zwischen Oberkante Sauna...

Страница 7: ...en Saunakabinen sind deswegen be reits in dem Wandelement mit der Zuluftöffnung Leerrohre für die Kabelverlegung eingefügt Sollten in Ihrer Kabine keine Leerrohre vorhanden sein bohren Sie unmittelbar neben dem Saunaheiz gerät dort wo das Kabel aus dem Saunaheizgerät herauskommt ein ausreichend großes Loch in die Kabinenwand und führen das Kabel durch dieses Loch nach außen und dann zum Steuergerä...

Страница 8: ... Kabinenvolumen 6 8 m 8 12 m 9 14 m Mindestmaß der Be und Entlüftung 35 x 4 cm 35 x 5 cm 35 x 6 cm Gewicht ohne Steine und Verpackung 13 5 kg Steinfüllung 15 kg nicht im Lieferumfang enthalten Verbindung Netz Saunaofen 5 x 1 5 max 10 m Ableitstrom max 0 75 mA je kW Heizleistung Steuereinheit eingebaut Temperatur Regelbereich 40 100 C Temperaturfühler Kapillarrohrfühler eingebaut Bestimmungsgemäßer...

Страница 9: ...lussplan sowie die Vorschriften des örtlichen EVU TAB 2000 und des VDE beachten Achtung Bauseitig muss in Ofenzuleitung eine ausreichende Absi cherung und ein Netztrennschalter installiert werden A1 A2 A3 B1 B2 B3 Thermostat Sicherheits temperaturbegrenzer M Netz Mains Réseau Сеть 400V AC 3N Zeitschaltuhr timer Thermostat overheat safty shutdown device reset 5 x 1 5 max 10 m A1 A1 B1 B A A Achtung...

Страница 10: ...echten Abstände zwischen Heizgerät und Kabinenwand sowie Ofen schutzgitter Liegebank und anderen brennbaren Materialien entnehmen Sie bitte Abb 1 Achtung Stellen Sie sicher dass die Mindestabstände eingehalten werden Feuergefahr Mindestabstände Abb 1 Kabinenwand 8 cm 33 cm 8 cm 44 cm 8 cm Ofenschutzgitter Abb 2 Die Höhe des Ofenschutzgitters muss etwa der vorderen Ofenhöhe entsprechen Abb 2 ...

Страница 11: ... der Lufteintrittsöffnung an der Kabinenwand befestigen Hierbei muß zum Einhängen des Saunaheizers ein Abstand von ca 2 mm zwischen Schraubenkopf und Kabinenwand vorhanden sein Um Ihnen die Positionierung der Schrauben zu erleichtern befindet sich auf dem Außen karton ein Aufdruck mit den benötigten Abständen Diesen können Sie als Bohrschablone verwenden 360 430 180 180 Maße in mm 2 min 120 Luftei...

Страница 12: ... hierbei darauf dass der Deckel so weit wie möglich unter den Rand des An schlusskastens geschoben wird Abb 7 Abb 5 Anschlussleitung nach Schaltplan anschließen Ein Schaltplan ist auf der Innenseite des Anschlusskasten Deckels angebracht Elektrischer Anschluss gemäß Abb 7 und Anschlussbeispiel ausführen Befestigen Sie das beiliegende Luftleitblech wie in Abb 5 dargestellt Hierzu die mittlere Schra...

Страница 13: ...gen Position zur Außenseite des Saunaheizgerätes hin befinden Jetzt können Sie das Saunaheizgerät mit den Schlüssellöchern in die bereits an der Kabi nenwand befestigten Spanplattenschrauben einhängen und anschließend mit den beiden Sicherungsschrauben an den Wandaufhängungen sichern Abb 8 Inbetriebnahme und Bedienung Durch Drehen des Zeitschaltuhr Dreh knopfs nehmen Sie das Saunaheizge rät in Bet...

Страница 14: ... der Kabine kann das Aufheizverhalten in der Kabine beeinflussen und führt zu Temperaturunterschieden Darüber hinaus gibt es in einer Sauna sehr große Temperaturunterschiede zwischen der Decke und dem unteren Bereich Hinzu kommt dass viele Bimetall Thermometer Wandanzeige sehr träge reagieren so dass teilweise erst nach ca einer Stunde die wirkliche Temperatur angezeigt wird Das Thermo meter sollt...

Страница 15: ...so muss dieser mechanisch zurückgesetzt werden ACHTUNG Trennen Sie zunächst das Saunaheizgerät vom Netz Drücken Sie nun den Einraststift des STB durch die runde Öffnung im Au ßenmantel mit einem Schraubendreher zurück bis Sie einen Schaltpunkt verspüren Abb 10 Der STB befindet sich nun wieder in seiner funktionsfähigen Ausgangsposition Sollte der STB nach Inbetriebnahme wieder auslösen muss das Ge...

Страница 16: ...ch die Saunasteine wie der ausreichend erhitzt ACHTUNG Geben Sie dem Aufgusswasser nie mehr Aufgussmittel oder äthe rische Öle bei als auf diesen Ge binden angegeben Verwenden Sie niemals Alkohol oder unverdünnte Konzentrate Brandgefahr ACHTUNG Steine im Steinbehälter des Saunaofens nicht aufschichten sondern grob auflegen damit möglichst viele Zwischenräume für die durchströmende Heißluft verblei...

Страница 17: ... leicht mit Flusen und Staub zusetzen Dadurch wird die Luftkonvektion des Saunaheizgerätes eingeschränkt und es können unzulässige Temperaturen auf treten Reinigen bzw Entkalken Sie die Geräte bei Bedarf Bei eventuell auftretenden Mängeln oder Verschleißspuren wenden Sie sich an Ihren Saunahändler oder direkt an das Her stellerwerk Sollten Sie Ihre Sauna über länger Zeit nicht benutzen vergewisser...

Страница 18: ... diesen FI Schalter abgesichert werden Nach dem heutigen Stand der Technik ist es nicht sinnvoll dampfdichte Rohr heizkörper für Saunaöfen einzusetzen Es kann vorkommen dass die Magnesi umoxidfüllung der Heizkörper durch den dampfdiffusen Silikonverschluss etwas Feuchtigkeit aus der Umgebungsluft zieht welches in wenigen Fällen zum Auslösen des FI Schutzschalters führen kann Dies ist ein Physikali...

Страница 19: ... Bitte diese Adresse zusammen mit der Montageanweisung gut aufbewahren Damit wir Ihre Fragen schnell und kompe tent beantworten können geben Sie uns immer die auf dem Typenschild vermerkten Daten wie Typenbezeichnung Artikel Nr und Serien Nr an Nicht mehr gebrauchte Geräte Leuchtmittel sind gem Richtlinie 2002 96 EG bzw ElektroG zum Re cyceln bei einer Wertstoffsammel stelle abzugeben Nicht mit de...

Страница 20: ...eges und ist grundsätzlich auf 12 Monate befristet Garantieleistungen erfolgen nur dann wenn der zum Gerät gehörige Kaufbeleg vorgelegt werden kann Bei Änderungen am Gerät die ohne ausdrückliche Zustimmung des Herstellers vorgenommen wurden verfällt jeglicher Garantieanspruch Für Defekte die durch Reparaturen oder Eingriffe von nicht ermächtigten Personen oder durch un sachgemäßen Gebrauch entstan...

Страница 21: ... electrical connections 26 Technical data 27 Connection example for the sauna system 28 Sauna heater assembly 29 Minimum clearances 29 Commissioning 32 Safety switch off 33 Sauna stones 34 Maintenance and care 34 Service Address 37 General terms and conditions of service 38 ...

Страница 22: ...d the goods Please note that you will only be able to achieve an optimum sauna climate if the cabin with its air intake and ventilation the sauna heater and the control unit are aligned to each other Please observe the information and stipula tions made by your sauna supplier Sauna heaters heat up your sauna cabin using heated convective air Here fresh air is drawn in from the air intake which whe...

Страница 23: ...cording to VDE 0100 of 49 DA 6 and VDE 0100 part 703 2006 2 must be observed Sauna heater and controller may onlybeusedinsaunacabinsmade of suitable low resin untreated materials e g spruce Only a sauna heater with the ap propriate power output may be installed in the sauna cabin Please provide air intake and vent openings in each sauna cab in The air intakes must always be positioned behind the s...

Страница 24: ...ntend ed for installation or set up in a niche under a bench or under a sloping roof Do not put the sauna heater into operation when the air intake is closed The cabin lighting and the cor responding installation in the splash protected version must comply with DIN EN VDE 0100 T 703 Therefore only approved sauna lamps with max 40 W may be used in connection with the sauna heater Only a locally cer...

Страница 25: ...ammable materials The heater protec tive grating must roughly accord with the front height of the sauna heater Please also note the information and instructions provided by the cabin manufacturer Please take precautions when cleaning components with sharp edges Upright heaters need to be fitted on site with elements that pre vent them from overturning Attention Pour the infusion water only on the ...

Страница 26: ...ion ducts or also be protected against damage on the outside of the cabin e g by laying them in installation pipes or attaching wood cover strips The sauna heater if used in commercial pub lic facilities and equipped with remote con trol may be used only in combination with the appropriate cover protection system Remote control means settings switching control and adjustment of the sauna control u...

Страница 27: ...protection 3 x 16 A Equipment size H x W x D 64 x 44 x 33 cm For sauna cabin size 6 8 m 8 12 m 9 14 m Min size air supply and duct vent 35 x 4 cm 35 x 5 cm 35 x 6 cm Weight without stones and packing 13 5 kg Stone filling 15 kg not included Connection mains heater 5 x 1 5 max 10 m Leakage current max 0 75 mA per kW of heating power Control unit built in Temperature control range 40 100 C Temperatu...

Страница 28: ...plier TAB 2000 and the legal norms Caution Anadequatefuseandamainscircuitbreakermustbeinstalled in the stove s power supply line on site A1 A2 A3 B1 B2 B3 Thermostat Sicherheits temperaturbegrenzer M Netz Mains Réseau Сеть 400V AC 3N Zeitschaltuhr timer Thermostat overheat safty shutdown device reset 5 x 1 5 max 10 m A1 A1 B1 B A A Achtung Immer Nulleiter N mit anklemmen 6 0 kW 3x 2000 W 7 5 kW 3x...

Страница 29: ...ety gaps between the heater and the cabin wall or the safety guard rail bench or other flammable materials must be not smaller as indicated in Fig 1 Attention make sure to observe the safety gaps Risk of fire Minimum clearances Fig 1 Cabin wall Protective grating for heater Fig 2 The installation height of the heater guard rail must be lined up with the top of the sauna heater see Fig 2 8 cm 33 cm...

Страница 30: ...l above the air intake as shown in Fig 3 There must be a clearance of approx 2 mm between the screw head and the cabin wall in order to attach the sauna heater An installation template with position of mounting screws is printed on the packaging of the heater You can use this as a drilling template Air intake Fig 3 Fig 4 Remove screws Transport protection 360 430 180 180 Maße in mm 2 min 120 ...

Страница 31: ...rews Ensure that the cover panel is pushed under the edge of the terminal box as far as possible Fig 7 Fig 5 Connect the power cable as shown in the wiring diagram There is a wiring diagram attached on the inside of the terminal box Electrical connection shall be made as per Fig 7 and connection example Attach the enclosed air deflector as shown in Fig 5 To do this first release the central screw ...

Страница 32: ...wall fixtures with the two locking screws Fig 8 Connect the power cable to the mains Please pay attention to the local safety norms and applicable regulations 60 cm 22 cm 4 cm Commissioning First use Rotate the timer knob in order to switch the sauna heater on By ro tating the switch you can determine the desired heating time align the arrow on the rotating knob with the corresponding time setting...

Страница 33: ...the lower zones are very typical One should also consider that conventional sauna thermometers with bi metal mechanism react slowly and need some time to show the current temperature Also their position in the sauna has a large influence on the displayed value We recommend to determine through practical tests the temperature setting which is most suitable to your personal preferences By rotating t...

Страница 34: ...ences or vola tile oils than advised on the pack aging Never use alcohol or undi luted concentrates Caution Fire hazard Sauna rocks Please be sure to note Do not insert sauna rocks too tightly in the rock store Place them loose leaving as many spaces as possible to allow the free flow of hot air for circula tion purposes Remove stones from the sauna heater only when they cooled down It cannot be e...

Страница 35: ...nvection in the sauna heating unit and can be a cause of too high temperatures Clean or de scale the heater when need ed Refer to your sauna supplier or directly to the manufacturer in case of defects or signs of wear and tear Only use original manufacturer s replace ment parts which can be obtained from your supplier or directly from the manufac turer If you did not use your sauna for a long pe r...

Страница 36: ...DIN VDE 0700 part 1 2012 10 states the following in paragraph 13 2 quote The leakage current may not exceed the fol lowing values during operation for stationary heaters of protection class I 0 75 mA or 0 75 mA each kW input of the appliance depending on the higher value at a maximum value of 5 mA If the appliance is equipped with a protec tive device for leakage current RCD please pay attention t...

Страница 37: ...mation printed on the type shield including the model item no and serial no in all in quiries Recycling Devices or lighting elements that will not be used any longer have to be handed in at a recycling station according to regulation 2002 96 EG Do not dispose it with the nor mal household waste Service address Monuments Handelsgesellschaft mbH Schneiderstriesch 1 35759 Driedorf GERMANY Tel 49 0 27...

Страница 38: ...all commence from the date on which proof of purchase is provided and shall be limited in principle to 12 months Warranty services shall be performed only if the proof of purchase relating to the equipment can be presented Any and all warranty claims shall become void if modifications are made to the equipment without the manufacturer s express consent Any warranty claim shall likewise become void...

Страница 39: ...ие характеристики 46 Пример подключения сауны 47 Монтаж нагревательного прибора сауны 48 Минимальные расстояния 48 Ввод в эксплуатацию Управление 51 Автоматическое отключение при перегреве 52 Камни для сауны 53 Техобслуживание и уход 53 Адреса сервисных центров 55 Общие условия обслуживания 56 ...

Страница 40: ...омпании или свяжитесь с поставщиком оборудова ния Обращаем ваше внимание на то что оп тимальные условия в сауне достигаются только при надлежащем согласовании системы подачи и отвода воздуха в ка бине нагревательного прибора сауны и блока управления Соблюдайте инструк ции и указания поставщика сауны Нагревательные приборы сауны нагре вают кабину сауны посредством разо гретого конвекцией воздуха Пр...

Страница 41: ...нагревательного прибора сау ны блока управления и других электрических приборов к ста ционарному источнику элек тропитания должны выпол няться только специалистом При этом необходимо соблю дать требуемые меры предо сторожности предписанные Союзом немецких электротех ников в стандарте VDE 0100 49 DA 6 и VDE 0100 часть 703 2006 2 Нагревательный прибор сауны и блок управления разреша ется использоват...

Страница 42: ... ции по монтажу производите ля Внимание накрытая или неправильно наполненная ем кость для камней может стать причиной пожара Перед каждым вводом в эксплуатацию проверяйте чтобы на нагревательном при боре сауны не лежали никакие предметы Внимание во время ра боты нагревательный прибор раскаляется поэтому при при косновении к нему можно по лучить ожоги Нагревательный прибор сауны не предназначен для...

Страница 43: ...итном чертеже У наполь ных печей расстояние опреде ляется по высоте основания или ножек Обязательно следите за тем чтобы нагревательный прибор сауны не устанавливался на полу изготовленном из возго раемых материалов дерева полимерного покрытия и т п Наиболее подходящим покры тием пола является керамиче ская плитка Подогрев пола в кабине сауны приводит к повышению темпе ратуры поверхности напольно ...

Страница 44: ...м с нагревательным при бором в том месте в котором из прибора выходит кабель Сквозь это отверстие выве дите кабель наружу и затем проведите его к блоку управ ления Как и все остальные со единительные кабели линия подводящая к сети и системе освещения кабины на внеш ней стенке кабины защитите этот кабель от повреждений например путем его проклад ки в специальных трубках или под деревянными защитным...

Страница 45: ...имание на то что в случае гарантийных претензий необходимо предъя вить копию счета от специали зированного предприятия ко торое выполняло работы либо иное подтверждение выполне ния работ специалистом При пользовании кабиной следует помнить о том что мак симальная температура кон тактных стеклянных поверхно стей с наружной стороны кабины не должна превышать макс 76 C При необходимости следу ет уста...

Страница 46: ... Г 64 x 44 x 33 см Для объема сауны 6 8 м 8 12 м 9 14 м Минимальный размер отверстий вентиляции 35 x 4 см 35 x 5 см 35 x 6 см Вес без камней и упаковки 13 5 kg Подключение сеть прибор 15 kg не входит в комплект поставки Подключение сеть прибор 5 x 1 5 max 10 м Ток утечки макс 0 75 мА на кВт отопительной мощности устройство управления встроенный Диапазон регулировки температуры 40 100 C Температурн...

Страница 47: ...ей на всех фа зах и системы отключения питания по всем фазам с зазором между контактами не менее 3 мм в разомкнутом состоянии A1 A2 A3 B1 B2 B3 Thermostat Sicherheits temperaturbegrenzer M Netz Mains Réseau Сеть 400V AC 3N Zeitschaltuhr timer Thermostat overheat safty shutdown device reset 5 x 1 5 max 10 m A1 A1 B1 B A A Achtung Immer Nulleiter N mit anklemmen 6 0 kW 3x 2000 W 7 5 kW 3x 2500 W 9 0...

Страница 48: ...стояния по горизонтали между нагревательным прибором и стенкой кабины а также защитной решеткой кабины полкой и другими воспламеняемыми материалами указаны на рис 1 Внимание убедитесь в соблюдении минимальных зазоров при монтаже печи Риск пожара Минимальные расстояния Рис 1 Стенка кабины Защитная решетка печи Рис 2 Высота защитной решетки печи должна быть не ниже высоты переднего края печи рис 2 8...

Страница 49: ...ад вентиляционным отверстием согласно рис 3 Для навешивания нагревательного прибора сауны между головкой шурупы и поверхностью стенки кабины должно оставаться примерно 2 мм Для облегчения монтажа на картонной упаковке напечатан шаблон с положением крепежных шурупов При помощи данного шаблона Вы можете ускорить и облег чить монтаж печи Вентиляционное отверстие Рис 3 Рис 4 Выкручивание винтов 360 43...

Страница 50: ...ышка была как можно дальше задвинута за край клеммной коробки Рис 7 Рис 5 Подключите соединительный провод согласно электрической схеме Электрическая схема расположена на внутренней стороне клеммной коробки Электроподключение согласно рис 7 и примеру подключения Закрепите входящий в комплект поставки воздухоотражатель как показано на рис 5 Для этого сначала выкрутите винт по центру крышки а затем ...

Страница 51: ...крученные в стенку кабины винты в отверстия в кронштейнах и затем зафиксировать его с помощью Рис 9 60 cm 22 cm 4 cm Ввод в эксплуатацию и управление Включение печи осуществляется пово ротом регулятора времени нагрева Мак симальное время работы печи 4 часа Шкала регулятор размечена для удоб ства на интервалы по 30 минут После поворота регулятора встроенный мотор будет поворачивать его обратно в ст...

Страница 52: ...ластине которая медленно реагирует на изменения температуры В резуль тате термометру требуется длительное время чтобы отобразить текущую температуру Также его положение и зазор по отношению к стене влияют на показания В результате этого возможно что тер мометр покажет более низкую темпе ратуру воздуха чем она есть на самом деле Печь для сауны оснащена предохранителем перегрева STB который автомати...

Страница 53: ... водой данные на упаковке Никогда не используйте неразбавленные ароматизаторы или алкоголь Риск возгорания Уход и обслуживание Все печи изготовлены из материалов с высокой устойчивостью к коррозии Что бы печь прослужила Вам долго и надеж но за ней следует правильно ухаживать При этом следует обращать внимание на то чтобы отверстие для притока возду ха в сауну и детали корпуса печи всегда было своб...

Страница 54: ...ождитесь чтобы камни до статочно остыли перед тем как дотрагиваться до них Не исключена возможность что камни или их части мо гут выпасть из поддона печи Риск пожара Камни для печи должны про веряться не реже одного раза в год и при необходимости за меняться Короб для камней должен заполнятся так чтобы была исключена возможность пря мого излучения от нагрева тельных элементов на стену сауны ...

Страница 55: ...просы указывайте данные приведенные на фирменной та бличке обозначение типа номер артику ла и серийный номер Дата покупки Печать и подпись дилера Адрес сервисного центра Monuments Handelsgesellschaft mbH Schneiderstriesch 1 35759 Driedorf GERMANY Германия Телефоны 49 0 2775 82 149 info monuments handelsgesellschaft de 55 RU ...

Страница 56: ...ежном документе и ограничен 12 месяцами Гарантийное обслуживание предоставляется только при наличии соответствующего платежного документа При внесении изменений в прибор без письменного разрешения производителя любые заявки на гарантийное обслуживание не принимаются Гарантия не распространяется на повреждения возникшие из за ремонта неуполномо ченными лицами или из за использования оборудования не...

Отзывы: