Failure description
Failure diagnosis
Trobleshooting
Ignition fails
There is fuel in the fire cup but it
is not ignited
Turn the dial off and on and try to
ignite again
No fuel in the fire cup because
the fuel pellet is too large to enter
the feeder
Change to smaller fuel
The feed screw stops
Check whether the circuit is
abnormal or change the feed
motor
The ignition rod does not work
Check whether the circuit is
abnormal or change the ignition
rod
Err” shows on the LCD
Failure of the sensor in the grill
Check or change the sensor in
the grill
Low temperature protection Detection temperature less
135
℉
for 6 min and power off
and display show ERL
Shut off the display, unplug the
power and plug the power again,
then start device
High temperature protection Temperature higher then
615
℉
power off and display show
ERH , fan keep running 10 min
and
temperature decrease to 130
℉
and shut off
Note
after failure, the control board must be reenergized and reset.
Trouble Shooting