![montpellier SP601W Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/montpellier/sp601w/sp601w_installation-and-operating-instructions-manual_1830912009.webp)
qualified person and following the regulations in force. When the appliance is to be
installed above a built-in oven, the two appliances must be connected separately.
The supply cable must be so positioned that no point can reach a temperature 50° C
higher than the ambient temperature. Also check that the supply system has an
effective earth connection and corresponds to the standards in force and that the
plug (or omnipolar switch) can be reached easily when the appliance is installed.
Fitting Guidelines
The voltage rating of the hob heating elements is 220-240V. Adapting the hob to
operate with one-phase current is possible by appropriate bridging in the connection
box according to the connection diagram below. The connection diagram is also
shown on the cover of the connection box. Remember that the connection wire
should match the connection type and the power rating of the hob.
The connection cable must be secured in a strain-Relief clamp.
CONNECTION DIAGRAM
Caution! Voltage of
heating elements 220-240V
Caution! In the event of
any connection the safety
wire must be connected to
the
E terminal.
Recommended
type of
connection lead
•
If the cable is damaged or to be replaced, the operation must be carried out
the by after-sale agent with dedicated tools to avoid any accidents.
•
If the appliance is being connected directly to the mains an omnipolar circuit-
breaker must
be installed with a minimum opening of 3mm between contacts
•
The installer must ensure that the correct electrical connection has been made
and that it
is compliant with safety regulations.
•
The cable must not be bent or compressed.
•
The cable must be checked regularly and replaced by authorised technicians only.