![montpellier MON-INT785 Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/montpellier/mon-int785/mon-int785_installation-and-operating-instructions-manual_1830910009.webp)
other cooking zones and changes the displayed power
level accordingly. The heat setting display of the reduced
zone(s) changes between four levels, e.g. if all zones are
on, the highest power levels of three zones are decrease to
level 5 (1000W), level 5 (1000W) and level 7 (1500W).
In Group (
a
) both cook zones can work at full power any time
as the maximum combined power is 3500W.
In Group (
b
) if two zones are working and you switch on the
third zone, the power of the third zone will be reduced to
level 7 (1500W) and the other two zones will drop to level 5
(1000W) automatically. If you want the third zone to work
at level 9 (2000W) you must turn off the other two zones.
9