montpellier CT750 Скачать руководство пользователя страница 7

           CONNECTION DIAGRAM
Caution! Voltage of heating 
elements 220-240V Caution! In the event 
of any connection the safety Wire 
must be connected to the          E terminal.

Recommended type of

connection lead

WARNING

Close the cable clamp after making the 

electrical connection. Close the terminal

board cover by twisting it down.

TERMINAL BOARD

Recommended installation

Wood block

If the cable is damaged or to be replaced, the operation must be carried out the by a service agent or a 

suitably qualified professional.

If the appliance is being connected directly to the mains, an omnipolar circuit breaker must be installed 

with a minimum opening of 3mm between contacts.

The installer must ensure that the correct electrical connection has been made and that it is compliant 

with all applicable standards  and safety regulations.

The cable must not be bent or compressed.

The cable must be checked regularly and replaced by authorised technicians only.

bracket

OR

screw

screw hold

Ventilation slot ≥ mm:30

50mm MIN.

Heat outlet

15mm MIN.

E

N

L

For 220-240V earthed one-phase
connection, bridges connect L

-

-

terminals andN

-

 terminals, safety

wire to

1-worktop

2-screw

3-bracket

4-hob

5-hob seal

2

 

1

 

3

4

5

 

50

50

200

200

Rear wall

Front edge of worktop

CT750 

CT750 

CT905

CT905

750

450

750

735

490

510

77

72

750

450

860

830

490

520

77

72

Содержание CT750

Страница 1: ...CT750 CT905 70 90cm 99min Timer...

Страница 2: ......

Страница 3: ...hey can get hot 13 CAUTION The surface temperature exceeds 95 C To avoid a hazard under bench access must be restricted Refer to the installation instructions 14 WARNING The appliance and its accessib...

Страница 4: ...area 145mm Heating area 145mm Heating area 180mm Heating area 180mm Heating area 180mm Heating area 120mm Heating area 145mm Heating area 180mm Heating area 145mm Heating area 180mm Heating area 180mm...

Страница 5: ...a hob zone even when its temperature has dropped below 60 C IMPORTANT The residual heat indicator will disappear if the mains supply to the product is cut Locking the ceramic hob To lock the ceramic...

Страница 6: ...isture on hotplate no utensil Bad Bad Bad Bad Bad Technical Data Model Power Supply Power W Size mm Buit in Hole Size mm AC220 240V 50Hz 180mm 145mm 180mm 120mm 1200W 1800W 1700W 700W 1200W 1800W 1700...

Страница 7: ...mains an omnipolar circuit breaker must be installed with a minimum opening of 3mm between contacts The installer must ensure that the correct electrical connection has been made and that it is compli...

Страница 8: ...Fixing bracket Hob Disassembly bottom base 4 bigger screws need to be removed first before bottom base disassembly Bottom base removal need to be done by professional person Normal user is not allowed...

Страница 9: ...g zones 190 190 Erp 7 This appliance is labelled in compliance with European directive 2012 19 EC for Waste Electrical and Electronic Equipment WEEE By ensuring that this appliance is disposed of corr...

Страница 10: ...Repair costs incurred that have not been authorised by Montpellier and or carried out by a non approved Montpellier engineer 01759 487839 01759 487839...

Страница 11: ......

Отзывы: