CONNECTION DIAGRAM
Caution! Voltage of heating
elements 220-240V Caution! In the event
of any connection the safety Wire
must be connected to the E terminal.
Recommended type of
connection lead
WARNING
Close the cable clamp after making the
electrical connection. Close the terminal
board cover by twisting it down.
TERMINAL BOARD
Recommended installation
Wood block
•
If the cable is damaged or to be replaced, the operation must be carried out the by a service agent or a
suitably qualified professional.
•
If the appliance is being connected directly to the mains, an omnipolar circuit breaker must be installed
with a minimum opening of 3mm between contacts.
•
The installer must ensure that the correct electrical connection has been made and that it is compliant
with all applicable standards and safety regulations.
•
The cable must not be bent or compressed.
•
The cable must be checked regularly and replaced by authorised technicians only.
bracket
OR
screw
screw hold
Ventilation slot ≥ mm:30
50mm MIN.
Heat outlet
15mm MIN.
E
N
L
①
②
④
⑤
①
②
④
⑤
③
③
For 220-240V earthed one-phase
connection, bridges connect L
①
-
②
-
③
terminals andN
④
-
⑤
terminals, safety
wire to
1-worktop
2-screw
3-bracket
4-hob
5-hob seal
2
1
3
4
5
50
50
200
200
Rear wall
Front edge of worktop
CT750
CT750
CT905
CT905
≥
750
450
750
735
490
510
77
72
≥
750
450
860
830
490
520
77
72