SP28-F2 Modular Series Fireplace
CAUTIONS
Due to its high operating temperatures, the appliance
should be located out of traffic & away from furniture and
draperies.
•
Children and adults should be alerted to the hazards
of the high surface temperature, which could cause
burns or clothing ignition.
•
Young children should be carefully supervised when
they are in the same room as the appliance.
•
Clothing or other flammable materials should not be
placed on or near the appliance.
Introduction
Thank you for purchasing the EC-Plus Modular Series Fireplace.
This fireplace is modular, allowing the installation of four different
decorative burner configurations or one heat-efficient model. The
modular concept provides the opportunity to upgradeeasily in the field
and customize to your immediate and future requirements.
The SP28-F2 Series is certified in British Columbia only which is
upgradable to the EP28-S2 insert, which is certified in the US and
Canada as a
Vented Gas Fireplace Heater
(ANSI Z21.88 - 2000 /
CSA 2.33 - 2000).
n
SP28-F2
- 5 logs, 22 000 BTU/H sandpan burner
(Nat. Gas only
). Available in British Columbia only.
n
EP28-S2
- 6 logs, 21 000 BTU/H heating insert
(Nat. Gas or LP).
The warranty will be voided by, and the manufacturer
disclaims any
responsibility for, the following actions:
n
Modification of the fireplace and/or components including
combustion air assembly or glass doors.
n
Use of any component part not manufactured or approved by the
manufacturer in combination with an EC-Plus fireplace system.
n
Installation other than as instructed in this manual.
Consult your local Gas Inspection Branch on installation requirements for
factory-built gas fireplaces. Installation & repairs should be done by a
qualified contractor.
Installations in Canada
must conform to the current
CAN/CGA B-
149.1
and
.2
Gas Installation Code and local regulations. When the unit
employs the optional Blower Kit, it must be electrically grounded in
accordance with
CSA C22.1
Canadian Electrical Code Part 1 and/or
Local Codes.
Installations in the USA
must conform to the National Fuel Gas Code,
ANSI Z223.1-1988
. When the unit employs the optional Blower Kit it
must be grounded in accordance with local codes or, in the absence of
local codes, with the National Electrical Code,
ANSI/NFPA 70-1987.
NOTE: Decorative burner models are not intended as a primary
source of heat. Use for supplemental heating only.
Table Of Contents
Introduction
............................................................................ 2
Installation
......................................................................... 3-11
Installing the Fireplace Shell ........................................... 3
Installing the Gasline ....................................................... 4
The Remote Switch ........................................................ 4
Vent Requirements ......................................................... 4
Construction around the fireplace
Facing ............................................................. 5
Mantels and Surrounds ...................................... 5
Installing the Decorative Burner Tray ............................. 6
Installing the Logset ........................................................ 7
Wiring ............................................................................ 7
Adjusting the Optional Doors ........................................... 8
Installing the Heating -S2 Insert ................................. 8-10
Operation
............................................................................... 11
Maintenance
..................................................................... 12-13
Warranty
................................................................................ 14