NOTE:
Remember, both sides of the Fireplace require the same quantities of wood, drywall and hardware.
Cut the Upper and Lower Horizontal 2 x 4's as shown in
Figure 2
. Next, cut the Required quantity of short filler 2x4's under the lower Horizontal.
Follow Typical building codes and practices when spacing. Next, cut the Required Left and Right Vertical 2 x 4's as shown in
Figure 3
.
Lastly, install the Two (2) Supplied Steel Headers above the fireplace throat positioned to attach facing material.
NOTE:
Whenthisassemblyisinplace,ensureALLtherequiredclearancestocombustiblesaremaintained
.
Figure 3 Sec.2
Fireplace installation,
Both Sides are Typical.
Step 4.
Installation of the RHS 102 heat shield (See "
Figure 7 Sec.4 on page 15
").
When the vent passes through the first adjacent ceiling (or wall for horizontal runs) a Montigo RHS102 heat shield must be installed around
the pipe as shown above.
See the detail of the RHS 102 on
page 13
.
1” clearance
1” clearance
Non-Combustible header
(supplied by Montigo)
2-pcs 2 x 4 (vertical)
Both Sides Typ
2 x 4, (Top
horizontal)
2 x 4, (Bottom
horizontal)
Both
Sides
Typ
(vertical)
use Typical
building
practices
when
spacing.
RHS 102
Note:
Images are shown without screens for clarity purposes.
However, your fireplace should not be operated without proper
installation of screens.
R520-ST & R620-ST Power Vent Indoor Gas Fireplace
Page 10
XG0773 - 150127
Installation