PVHFL58-300 Vertical Power Vent System

Installation

Figure 4. 

 HSI Wiring Diagram

115

R1 R2 R3

R1

R2

LED

Power

Indicator

PV

Plug

PV Speed 

Controller

Ye

llo

w

Ye

llo

w

Blac
k

Blue

Blue

Bro

w

n

Yellow

Blue

Black

White

White

1

2

3

4

5

Heat

Sensor

Flue

Gas Switch

Wall

Switch

Orange

W

h

ite

Blac

k

B

lk

/W

h

t

Wht/Blk

Blue

R

ed

B

ro

w

n

NC

Heat

Sensor

NO

Flue 

Gas Switch

ELECTRICAL CONTROL  BOX

R3

Gas

Valve

Wall

Switch

Fuse 

115 Volts

60Hz

5A

Post Purge

Timer

Pre-Purge 

Timer

Honeywell (Q3450)
Pilot Assembly

Pilot Electrical
Harness Connector

Honeywell Gas
Control (SV9501M)

Gas Control
Connector

Green

Black

White

Switch or Dimmer

(Not Supplied)

Power for Lights

115VAC, 700W

FIREPLACE CONTROLS

Red Tube

Clear Tube

Grey Pressure Tap

Black Pressure Tap

Page 7

XG0519 - 031114

Содержание PVHFL58-300

Страница 1: ...field Optical radiation Non ionizing radiation Radiation Hazardous to the Environment Danger of harming your hands Irritant Cutting Watch your step Slippery floor High temperatures Glass hazard Danger of suffocation High voltage Toxic Flammable materials Corrosive Fork lift trucks Danger overhead crane Explosion risk Oxidising Danger of death Biohazard Laser Radiation Danger of entrapment Hot surf...

Страница 2: ...PVHFL58 300 Vertical Power Vent System Safety Alert Key 3 Introduction 3 Product Dimensions 4 Installation 5 Wiring Diagram 6 7 Appendix 8 9 Appendix A Warranty 8 Appendix B State of Massachusetts 9 Page 2 XG0519 031114 ...

Страница 3: ... 20 foot power cord and harness EPVH30 30 foot power cord and harness EPVH40 40 foot power cord and harness EPVH50 50 foot power cord and harness EPVH60 60 foot power cord and harness EPVH70 70 foot power cord and harness EPVH80 80 foot power cord and harness EPVH90 90 foot power cord and harness EPVH100 100 foot power cord and harness Specifications Before Your Begin Voltage 115 Volts Frequency 6...

Страница 4: ...8 538 12 1 4 311 5 126 8 203 2 50 24 5 8 627 PVHFL58 300 Flush Louvered Power Vent 18 3 4 476 22 1 4 565 21 1 8 538 12 1 4 311 2 50 24 5 8 627 16 5 8 421 Top View Back Cover Collar Outer Assembly Inner Assembly Louver Assembly 18 3 4 476 Framing Step 1 1 Construct the support framing within the measurements as shown here The dimensions shown here are minimum dimensions to attach the Outer Assembly...

Страница 5: ...embly Step 3 Place the front grill into the outer can assembly by inserting the top tabs into the upper frame and securing the bottom with 2 screws provided Figure 2 Installing Flush Wall Mounted Power Vent Structure Outer Can Assembly Inner Can Assembly Power Cord from Power Vent Power Cord From Fireplace Electrical Plate Strain Relief Molex Connectors Step 2 Remove Electrical Plate from rear of ...

Страница 6: ...ng to the fireplace as oulined in the schematic shown in figure 4 Ensure that the proper clearances are maintained for the wiring and conduit When installing the wiring it must never run above the vent run and it must be at least 1 clear of all venting 1 Clearance Wire Figure 3 Conduit and Wiring Wiring Installation Page 6 XG0519 031114 ...

Страница 7: ...White Black Blk Wht Wht Blk Blue Red Brown NC Heat Sensor NO Flue Gas Switch ELECTRICAL CONTROL BOX R3 Gas Valve Wall Switch Fuse 115 Volts 60Hz 5A Post Purge Timer Pre Purge Timer Honeywell Q3450 Pilot Assembly Pilot Electrical Harness Connector Honeywell Gas Control SV9501M Gas Control Connector Green Black White Switch or Dimmer Not Supplied Power for Lights 115VAC 700W FIREPLACE CONTROLS Red T...

Страница 8: ... Appliance must be subjected to normal use The Gas Appliances are designed to burn gas only Burning conventional fireplace fuels such as wood coal or any other solid fuel will cause damage to the Gas Appliance will produce excessive temperatures and will result in a fire hazard Limitations On Liability It is expressly agreed and understood that The Companies sole obligation and purchaser s exclusi...

Страница 9: ...rade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS 4 INSPECTION The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless upo...

Страница 10: ...Ferndale Washington TF 1 800 789 6236 FX 1 866 3000 0927 XG0519 031114 Langley British Columbia TF 1 800 378 3115 FX 1 604 607 6462 PVHFL58 300 Power Vent Termination ...

Отзывы: