L42DF-ST* Indoor Gas Fireplace

XG0182 - 151126

Installation

Section A: Before you Start 

IMPORTANT MESSAGE: SAVE THESE INSTRUCTIONS

The L42DF*-ST Direct Vent fireplace must be installed in accordance 

with these Instructions. Carefully read all the Instructions in this 

manual first. Consult the Local Gas Branch to determine the need 

for a permit prior to starting the installation. It is the responsibility 

of the installer to ensure this fireplace is installed in compliance 

with the manufacturers instructions and all applicable codes.

Installation Checklist

 

„

Determine the desired install location of your fireplace. 

 

„

See Section 1, Dimensions on Page 6, and refer to the 

Framing Section 2 for details. 

 

„

Select the location of your termination and resulting vent run.

 

„

Your selected termination location must be the highest point 

in the Direct Vent installation.

 

„

Should it be impossible to meet the venting requirements laid 

out in Section 3: Venting, please contact Montigo regarding 

the use of a Montigo Power Vent.

 

„

Lay out the Vent run; calculating the required elbows and 

straight runs of 5"/8" flex and/or rigid pipe.

 

„

Layout Electrical Requirements Refer to Section 4: Wiring, 

for Details.

 

„

Refer to Section 5: Installing the Gas Line, for details on the 

gas connection and access.

 

„

Refer to local codes and guidelines for installation 

requirements.

 

„

Installation  and  repairs  should  be  done  by  a  qualified 

contractor and must conform to:

• Installations in Canada must conform to the local codes or in the 

absence of local codes to the current version of Natural Gas and 

Propane Installation Code, CSA B149. Electrical Installations must 

conform to the local codes or, in the absence of local codes, to the 

current version of Canadian Electrical Code, CSA C22.1.1

• Installations in the USA must conform to the local codes or in the 

absence of local codes to the current version of National Fuel Gas 

Code, ANSI Z223.1/NFPA 54. Electrical Installations must conform 

to the local codes or, in the absence of local codes, to the current 

version of the National Electrical Code, ANSI/NFPA 70.  See Appendix 

C for installation within the State of Massachusetts..

Installation and repairs should be done by an authorized gas fireplace service technician. 

The appliance should be inspected before use and at least annually by a professional. More 

frequent cleaning may be required due to excessive lint from carpeting, bedding material, 

etc. It is imperative that control compartments, burners and circulating air passageways of 

the fireplace are kept clean.

NOTICE

Due to high operating temperatures, this appliance should  be located out of traffic & 

away from furniture and draperies.

Children and adults should be alerted to the hazards of the high surface temperature, 

which could cause burns or clothing ignition.

Young children should be carefully supervised when they are in the same room as the 

appliance.

Clothing or other flammable materials should not be placed on or near the appliance.

CAUTION

When this appliance is installed directly on any combustible material other than wood 

flooring, it must be installed on a metal or wood panel extending the full width and 

depth of the appliance or a fire will occur causing serious injury,  property damage or 

even death.

DANGER

WARNING

A barrier designed to reduce the risk of burns from hot viewing glass is provided with this 

appliance and shall be installed for the protection of children and other at-risk individuals.

If the barrier becomes damaged, the barrier shall be replaced with the manufacturer’s 

barrier for this appliance.

WARNING

Any safety screen, guard, or barrier removed for servicing an appliance must be replaced

prior to operating the appliance.

Содержание L42DF ST

Страница 1: ...d Optical radiation Non ionizing radiation Radiation Hazardous to the Environment Danger of harming your hands Irritant Cutting Watch your step Slippery floor High temperatures Glass hazard Danger of...

Страница 2: ...tion 3 2 1 Venting Layout 11 Roof mounted Terminations 11 Section 3 3 Installing a Wall Mounted Direct Vent Termination 13 Section 3 3 1 Venting Layout Wall mounted termination 14 Section 3 3 2 Ventin...

Страница 3: ...ation and care of this fireplace can be easily performed by the homeowner All installation and service work should be performed by a qualified or licensed installer plumber orgasfitterascertifiedbythe...

Страница 4: ...lations in the USA must conform to the local codes or in the absence of local codes to the current version of National Fuel Gas Code ANSI Z223 1 NFPA 54 Electrical Installations must conform to the lo...

Страница 5: ...Page 5 L42DF ST Indoor Gas Fireplace XG0182 151126 Installation Rating Plate Sample Figure A Rating Plate for L42DF ST LBL1205 V6 1 Stand Pilot Screen DEC06 2014 Teklynx LabelView Demo...

Страница 6: ...may be installed in any location that maintains proper clearances to air conditioning ducts electrical wiring and plumbing Safety as well as efficiency of operation shouldbeconsideredwhenselectingthe...

Страница 7: ...raming above fireplace Left side see figure 2 Top Vent 12 Min Combustible shelf Supplied shield 90 1 Min 1 Min L P N G 12 Max 41 Min N G 54 Min L P 12 NG 17 LP Min PEL Short 90 elbow Supplied shield C...

Страница 8: ...Top Vent applications the minimum clearance is 17 for LP and 12 for NG from the top of the fireplace to the underside of any combustible shelf MODEL Top Top vent LP Top Top vent NG Top Side vent Sides...

Страница 9: ...h framing as shown in figure 7a Installing the Nailing Flange Extension Once the fireplace is placed into the rough framed opening and the heat guards are fastened the supplied Nailing Flange Extensio...

Страница 10: ...hat it provides the shortest vent run possible Should it be impossible to ensure that the termina tion is the highest point or should it be impossible to meet the venting guidelines laid out below ple...

Страница 11: ...e following guidelines The maximum termination point is 32 above the fireplace NOTE ifthemaximumterminationheightisused theflame pattern may be affected The Vertical termination must be a minimum 2 hi...

Страница 12: ...Installation Figure 10c Side vent Roof mounted venting 1 90 bend PEXT Solid Section PVTK1 Termination 12 Max Note Images are shown without screens for clarity purposes However your fireplace should no...

Страница 13: ...the MOSR by installing a min quantity of 4 bolts into the threaded nuts on the MOSR Frame Installation of termination frame at time of framing in Masonry Terminations with a BSR frame allow the instal...

Страница 14: ...nted installation with 1 elbow 1 one 90 bend The vent run must comply with Venting Graph for Top vent wall mounted terminations Figure 14 Figure12b TopVented wallmountedMulti elbowinstallation SeeVent...

Страница 15: ...wall mounted Retracted Multi elbow installation See Venting Graph for Top vent wall mounted terminations Figure 12 Heat Shield 96 Min 120 Max Note Images are shown without screens for clarity purpose...

Страница 16: ...bove the top boundary of the shaded area the installation is acceptable Example A Acceptable Installation If the vertical dimension from the hearth is 120 and the horizontal run to the wall flange of...

Страница 17: ...y combustible material Rigid pipe may be cut less than half way from the female end only Ensure when cutting sections of rigid pipe to maintain integrity of internal supports Place the springs supplie...

Страница 18: ...HS101 Heat shield MUST be used where the RHS8 Termination Figure 14 and 14a CANNOT be used Use the RHS101 whereanyofthedimensionsarewithintheparametersshown figure 14a ToinstalltheRHS101 SlidetheInner...

Страница 19: ...ng Diagram for SIT Nova 820 gas and pilot Models Included L42DF STN L42DF STL Section 4 Wiring Figure 16 Wiring Diagram for the SIT Proflame 2 Electronic Ignition 1 5V AA type 1 5V AA type 1 5V AA typ...

Страница 20: ...fireplace will then attempt to re light a second or third time depending on prevailing temperatures or altitude When in CPI mode the pilot also keeps the system warm During a cold start condensation...

Страница 21: ...wall switch Do NOT connect any external power to the remote switch The valve will generate its own power on a millivolt circuit or will draw its power from an AC Connection inside the fireplace depend...

Страница 22: ...s control valves have a provision to remove a 1 8 N PT plug to be fitted with a hose barb Montigo requires a service shut off valve be located in an accessible location to isolate the gas supply Onlyi...

Страница 23: ...ill interfere with the access to retainers for removal of glass door Figure 22 Combustible surrounds Typical both sides Mantels Surrounds NOTE NationalCanadianGasAssociationmanteltestrequirements are...

Страница 24: ...Remove Screens Grasp each top outer corner of the screen with your thumb andfingerandpulltowardsyourself WhentheupperScreen Studs are free lift the screen at an angle from the lower slots from which...

Страница 25: ...der 2 Step 5 Ensure the tool is firmly in the lower end of the slot asshown Thenpull towardyou Caution hold the tool securely 3 Step 6 Pull hard if necessary to release the spring tension Caution The...

Страница 26: ...be spaced at random or in a visual pattern of your preference in the burner pan See the Montigo web site for photographs and ideas www montigo com Installing Firestones in Natural Gas and Propane Fire...

Страница 27: ...nnot be turned from PILOT to OFF unless knob is pushed in slightly Do not force Standing Continuous Pilot Ignition SIT NOVA 820 with American Flame Electronic Ignition For Your Safety READ BEFORE LIGH...

Страница 28: ...o to the next step 6 Turn fireplace ON using wall switch or remote control 7 If the Fireplace does not light the System will cycle through two trials one minute audible clicking thirty seconds of sile...

Страница 29: ...Mode Key is provided to index between the features and a Thermostat Key is used to turn On Off or index through Thermostat functions see Figure 25 Additionally a Key Lock feature is provided The Profl...

Страница 30: ...ok at the LCD screen on the Remote Control to verify that a C or F is visible to the right of the Room Temperature display Turn On the Fireplace With the system Off turn the master override switch to...

Страница 31: ...on the remote control will change to show that the room thermostat is On and the set temperature is now displayed To adjust the set temperature press the Up or Down Arrow Keys until the desired set t...

Страница 32: ...s function use the Mode Key see Figure 25 to index to the accent light icon see Figure 25m Pressing the Up Arrow Key will turn the light on at the lowest setting Continue pressing up to get brighter P...

Страница 33: ...Keys at the same time see Figure 25o To de activate this function press the Mode and Up Keys at the same time Remote Control When the Remote Control batteries are low a Battery Icon will appear on th...

Страница 34: ...ucts is Kel Kem Silicone seals on inner door during initial firing will off gas leaving a visual deposit of a white substance on combustion chamber walls This can easily be removed from the chamber wa...

Страница 35: ...low the valve cover and turn ON 2 Ensure main power is ON or new batteries are installed in the remote control and backup battery pack if available 3 Checkthe3 15Afuseinthecontrol box and replace if n...

Страница 36: ...RPG001 Piezo Ignitor PIEZO Pilot Tubing RPTA03 Door RDTL42 Replacement Screen RSCP42 SIT IPI Proflame 2 Replacement Parts List L42DF ST NG Gas Valve Hi Low RGC3044 LP Gas Valve Hi Low RGC3045 NG Gas...

Страница 37: ...iance 100 000 BTU H 30 KW 12 inches 12 inches M clearance to forced air supply inlet 6 feet 3 feet above air inlet N clearance above paved sidewalk or paved driveway located on public property 7 feet...

Страница 38: ...ce must be subjected to normal use The Gas Appliances are designed to burn gas only Burning conventional fireplace fuels such as wood coal or any other solid fuel will cause damage to the Gas Applianc...

Страница 39: ...ht of eight 8 feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one...

Страница 40: ...XG0182 151126 L42DF ST Residential Gas Fireplace...

Отзывы: