background image

Page 38

L42DF-ST* Indoor Gas Fireplace

XG0182 - 151126

Appendix

Appendix B: Warranty

The Warranty

The Companies warrants the Montigo Gas Appliance to be free from defects in materials and workmanship at the time of manufacture. On the Montigo 

fireplace, there is a ten-year warranty on the firebox and its components, a five-year warranty on the main burner and pilot burner, and a one-year warranty 

on the gas control valve, fibre logs and Power Vent Module. The Glass, plated / painted finishes, and refractory lining are exempt from the warranty.

Remedy And Exclusions

The coverage of this Warranty is limited to all components of the Gas Appliance manufactured by The Companies.
This Warranty only covers Montigo Gas Appliances installed in the United States or Canada.
If the components of the Gas Appliance covered by this Warranty are found to be defective within the time frame stated (see The Companies right of 

investigation outlined below). The Companies will, at its option, replace or repair defective components of the Gas Appliance manufactured by The 

Companies at no charge, and will also pay for reasonable labour costs incurred in replacing or repairing components. If repair or replacement is not 

commercially practical, The Companies will, at its option, refund the purchase price of the Montigo Gas Appliance. 
This Warranty covers only parts and labour as provided above. In no case shall The Companies be responsible for materials, components, or construction 

which are not manufactured or supplied by The Companies, or for the labour necessary to install, repair or remove such materials, components or 

construction. All replacement or repair components will be shipped F.O.B. the nearest The Companies factory. 

Qualifications To The Warranty

The Gas Appliance Warranty outlined above is further subject to the following qualifications:

(1)  The Gas Appliance must be installed in accordance with The Companies installation instructions and local building codes. The Warranty on this 

Montigo Gas Appliance covers only the component parts manufactured by The Companies. The use of components manufactured by others with 

this Montigo Gas Appliance could create serious safety hazards, may result in the denial of certification by recognized national safety agencies, 

and could be in violation of local building codes. This warranty does not cover any damages occurring from the use of any components not 

manufactured or supplied by The Companies

(2)  The Montigo Gas Appliance must be subjected to normal use. The Gas Appliances are designed to burn gas only. Burning conventional fireplace 

fuels such as wood, coal or any other solid fuel will cause damage to the Gas Appliance, will produce excessive temperatures and will result in 

a fire hazard.

Limitations On Liability

It is expressly agreed and understood that The Companies sole obligation, and purchaser's exclusive remedy under this Warranty, under any other 

warranty, expressed or implied, or in contract, tort or otherwise, shall be limited to replacement, repair, or refund, as specified above.

In no event shall The Companies be responsible for any incidental or consequential damages caused by defects in its products, whether such damage 

occurs or is discovered before or after replacement or repair, and whether or not such damage is caused by The Companies negligence. Some states do 

not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. The duration of 

any implied warranty with respect to this Montigo Gas Appliance is limited to the duration of the foregoing warranty. Some states do not allow limitation 

on how long an implied warranty lasts, so the above may not apply to you.

Investigation Of Claims Against Warranty

The Companies reserves the right to investigate any and all claims against this Warranty and to decide upon method of settlement.

The Companies Are Not Responsible For Work Done Without Written Consent

The Companies shall in no event be responsible for any warranty work done without first obtaining The Companies written consent.

Dealers Have No Authority To Alter This Warranty

The Companies employees and dealers have no authority to make any warranties nor to authorize any remedies in addition to or inconsistent with 

those stated above.

How To Register A Claim Against Warranty

In order for any claim under this Warranty to be valid, The Companies must be notified of the claimed defect in writing or by telephone, as soon as 

reasonably possible after the defect is discovered. Claims against this Warranty in writing should include the date of installation, and a description 

of the defect.

Other Rights

This Warranty gives you specific legal rights, and you may also have other rights which vary from state to state.

NOTE: 

The Companies as stated above refer to - Canadian Heating Products Inc. and/or Montigo Del Ray Corp.

Canadian Heating Products Inc. and/or Montigo DelRay Corp. reserves the right to make changes at any time, without notice, in design, 

materials, specifications, prices and also to discontinue colors, styles and products.

Содержание L42DF ST

Страница 1: ...d Optical radiation Non ionizing radiation Radiation Hazardous to the Environment Danger of harming your hands Irritant Cutting Watch your step Slippery floor High temperatures Glass hazard Danger of...

Страница 2: ...tion 3 2 1 Venting Layout 11 Roof mounted Terminations 11 Section 3 3 Installing a Wall Mounted Direct Vent Termination 13 Section 3 3 1 Venting Layout Wall mounted termination 14 Section 3 3 2 Ventin...

Страница 3: ...ation and care of this fireplace can be easily performed by the homeowner All installation and service work should be performed by a qualified or licensed installer plumber orgasfitterascertifiedbythe...

Страница 4: ...lations in the USA must conform to the local codes or in the absence of local codes to the current version of National Fuel Gas Code ANSI Z223 1 NFPA 54 Electrical Installations must conform to the lo...

Страница 5: ...Page 5 L42DF ST Indoor Gas Fireplace XG0182 151126 Installation Rating Plate Sample Figure A Rating Plate for L42DF ST LBL1205 V6 1 Stand Pilot Screen DEC06 2014 Teklynx LabelView Demo...

Страница 6: ...may be installed in any location that maintains proper clearances to air conditioning ducts electrical wiring and plumbing Safety as well as efficiency of operation shouldbeconsideredwhenselectingthe...

Страница 7: ...raming above fireplace Left side see figure 2 Top Vent 12 Min Combustible shelf Supplied shield 90 1 Min 1 Min L P N G 12 Max 41 Min N G 54 Min L P 12 NG 17 LP Min PEL Short 90 elbow Supplied shield C...

Страница 8: ...Top Vent applications the minimum clearance is 17 for LP and 12 for NG from the top of the fireplace to the underside of any combustible shelf MODEL Top Top vent LP Top Top vent NG Top Side vent Sides...

Страница 9: ...h framing as shown in figure 7a Installing the Nailing Flange Extension Once the fireplace is placed into the rough framed opening and the heat guards are fastened the supplied Nailing Flange Extensio...

Страница 10: ...hat it provides the shortest vent run possible Should it be impossible to ensure that the termina tion is the highest point or should it be impossible to meet the venting guidelines laid out below ple...

Страница 11: ...e following guidelines The maximum termination point is 32 above the fireplace NOTE ifthemaximumterminationheightisused theflame pattern may be affected The Vertical termination must be a minimum 2 hi...

Страница 12: ...Installation Figure 10c Side vent Roof mounted venting 1 90 bend PEXT Solid Section PVTK1 Termination 12 Max Note Images are shown without screens for clarity purposes However your fireplace should no...

Страница 13: ...the MOSR by installing a min quantity of 4 bolts into the threaded nuts on the MOSR Frame Installation of termination frame at time of framing in Masonry Terminations with a BSR frame allow the instal...

Страница 14: ...nted installation with 1 elbow 1 one 90 bend The vent run must comply with Venting Graph for Top vent wall mounted terminations Figure 14 Figure12b TopVented wallmountedMulti elbowinstallation SeeVent...

Страница 15: ...wall mounted Retracted Multi elbow installation See Venting Graph for Top vent wall mounted terminations Figure 12 Heat Shield 96 Min 120 Max Note Images are shown without screens for clarity purpose...

Страница 16: ...bove the top boundary of the shaded area the installation is acceptable Example A Acceptable Installation If the vertical dimension from the hearth is 120 and the horizontal run to the wall flange of...

Страница 17: ...y combustible material Rigid pipe may be cut less than half way from the female end only Ensure when cutting sections of rigid pipe to maintain integrity of internal supports Place the springs supplie...

Страница 18: ...HS101 Heat shield MUST be used where the RHS8 Termination Figure 14 and 14a CANNOT be used Use the RHS101 whereanyofthedimensionsarewithintheparametersshown figure 14a ToinstalltheRHS101 SlidetheInner...

Страница 19: ...ng Diagram for SIT Nova 820 gas and pilot Models Included L42DF STN L42DF STL Section 4 Wiring Figure 16 Wiring Diagram for the SIT Proflame 2 Electronic Ignition 1 5V AA type 1 5V AA type 1 5V AA typ...

Страница 20: ...fireplace will then attempt to re light a second or third time depending on prevailing temperatures or altitude When in CPI mode the pilot also keeps the system warm During a cold start condensation...

Страница 21: ...wall switch Do NOT connect any external power to the remote switch The valve will generate its own power on a millivolt circuit or will draw its power from an AC Connection inside the fireplace depend...

Страница 22: ...s control valves have a provision to remove a 1 8 N PT plug to be fitted with a hose barb Montigo requires a service shut off valve be located in an accessible location to isolate the gas supply Onlyi...

Страница 23: ...ill interfere with the access to retainers for removal of glass door Figure 22 Combustible surrounds Typical both sides Mantels Surrounds NOTE NationalCanadianGasAssociationmanteltestrequirements are...

Страница 24: ...Remove Screens Grasp each top outer corner of the screen with your thumb andfingerandpulltowardsyourself WhentheupperScreen Studs are free lift the screen at an angle from the lower slots from which...

Страница 25: ...der 2 Step 5 Ensure the tool is firmly in the lower end of the slot asshown Thenpull towardyou Caution hold the tool securely 3 Step 6 Pull hard if necessary to release the spring tension Caution The...

Страница 26: ...be spaced at random or in a visual pattern of your preference in the burner pan See the Montigo web site for photographs and ideas www montigo com Installing Firestones in Natural Gas and Propane Fire...

Страница 27: ...nnot be turned from PILOT to OFF unless knob is pushed in slightly Do not force Standing Continuous Pilot Ignition SIT NOVA 820 with American Flame Electronic Ignition For Your Safety READ BEFORE LIGH...

Страница 28: ...o to the next step 6 Turn fireplace ON using wall switch or remote control 7 If the Fireplace does not light the System will cycle through two trials one minute audible clicking thirty seconds of sile...

Страница 29: ...Mode Key is provided to index between the features and a Thermostat Key is used to turn On Off or index through Thermostat functions see Figure 25 Additionally a Key Lock feature is provided The Profl...

Страница 30: ...ok at the LCD screen on the Remote Control to verify that a C or F is visible to the right of the Room Temperature display Turn On the Fireplace With the system Off turn the master override switch to...

Страница 31: ...on the remote control will change to show that the room thermostat is On and the set temperature is now displayed To adjust the set temperature press the Up or Down Arrow Keys until the desired set t...

Страница 32: ...s function use the Mode Key see Figure 25 to index to the accent light icon see Figure 25m Pressing the Up Arrow Key will turn the light on at the lowest setting Continue pressing up to get brighter P...

Страница 33: ...Keys at the same time see Figure 25o To de activate this function press the Mode and Up Keys at the same time Remote Control When the Remote Control batteries are low a Battery Icon will appear on th...

Страница 34: ...ucts is Kel Kem Silicone seals on inner door during initial firing will off gas leaving a visual deposit of a white substance on combustion chamber walls This can easily be removed from the chamber wa...

Страница 35: ...low the valve cover and turn ON 2 Ensure main power is ON or new batteries are installed in the remote control and backup battery pack if available 3 Checkthe3 15Afuseinthecontrol box and replace if n...

Страница 36: ...RPG001 Piezo Ignitor PIEZO Pilot Tubing RPTA03 Door RDTL42 Replacement Screen RSCP42 SIT IPI Proflame 2 Replacement Parts List L42DF ST NG Gas Valve Hi Low RGC3044 LP Gas Valve Hi Low RGC3045 NG Gas...

Страница 37: ...iance 100 000 BTU H 30 KW 12 inches 12 inches M clearance to forced air supply inlet 6 feet 3 feet above air inlet N clearance above paved sidewalk or paved driveway located on public property 7 feet...

Страница 38: ...ce must be subjected to normal use The Gas Appliances are designed to burn gas only Burning conventional fireplace fuels such as wood coal or any other solid fuel will cause damage to the Gas Applianc...

Страница 39: ...ht of eight 8 feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one...

Страница 40: ...XG0182 151126 L42DF ST Residential Gas Fireplace...

Отзывы: