Page 19
L38DF* Indoor Gas Fireplace
XG0180 - 053111
Installation
Section 7: Installing & Removing the Door
Removing the door:
The
L38DF*
doors are removed in a few simple steps. Follow these
below to remove the Horizontal access panel, unlatch the door buckles
and, remove the door. Replace in reverse order.
Remove the Horizontal Access Panel:
Figure 26a.
Locate the door buckles. (Both Sides Typical)
Door Latch Hook
Door Latch Slot
Hand-hold
Release the Door Buckles
Figure 26.
Removing and installing the the Horizontal Access Panel
Locate the Door Buckles:
Figure 26b.
Door buckle Tool
1
Step 4:
Firmly grasp hand-hold end
of Door buckle tool and
place the machined end in
the slot under door frame.
(as shown)
Figure 26c.
Step 2:
Step 3:
Step 1:
Remove the Horizontal cover
by placing fingers in both finger
holes, then pushing away from
you and lifting out. Place it aside
during maintenance or cleaning.
Install in reverse order.
Installed Gas
Valve Cover
Finger Holes
Remove the Horizontal Access Panel:
To install the door, hook the top edge of the door frame into place. Lower
the door into position and follow the previous steps shown in reverse order.
Installing the Door:
2
Step 5:
Ensure the tool is firmly in
the lower end of the slot,
(as shown), Then pull toward
you (Caution: hold the tool
securely).
3
Step 6:
Pull hard if necessary to
release the spring tension.
(Caution: The latch springs
back with force, hold the tool
securely).
4
Step 7:
Remove the tool from the
latch slot. Ensure the latches
are hanging freely, the hook
end is released from the
bottom of the door. (Repeat
all 4-steps for the remaining
latches).
Figure 26d.
Figure 26e.
Figure 26f.
Step 8:
Grasp the Door on either side, usually midway and lift upward, lift
the door carefully up and away from the front of the fireplace.
See
Figures 26g
. Place the Door aside in a safe place while maintenance
and / or cleaning is being performed.
Figure 26g.
Removing and installing the glass doors. (Both Sides
Typical)
Removing the Door: