background image

Page 16

Hotshot Gas Fireplace Insert

XG0511 - 150203

Maintenance

CAUTIONS

  Fireplace gas control must be in the “OFF” position and pilot 

and main burners extinguished when cleaning appliance with 

a vacuum. 

  Doors and logs can get very hot. Handle only when cool.

General

  Have the fireplace installation inspected yearly, including a visual 

check of the insert and vent system, the burner and the pilot flame. 

For your convenience a 1/8" manifold pressure tap is supplied on 

the gas valve for a test gauge connection. See 

Figure 13

.  

 For 

Natural Gas

 this appliance requires a minimum inlet pressure 

of 5.5" W.C. and a manifold pressure of 3.5" W.C.

 For 

Propane Gas 

this appliance requires a minimum inlet pres-

sure of  11" W.C. and a manifold pressure of 10" W.C.

  Always keep the fireplace area clear and free of combustible 

materials, as well as gasoline and other flammable vapours and 

liquids. 

  Do not use this appliance if 

any part has been under water

. Imme-

diately call a qualified service technician to inspect the appliance 

and to replace any part of the control system and any gas control 

which has been under water.

Cleaning

WARNING:

Do not attempt to clean glass when hot.
Do not clean glass with abrasive materials as any glass etch-

ing may cause premature glass failure. 

When the fireplace is first activated, there may be some smoking and 

a visible film may be left on the glass. This is a normal condition, and 

is the result of burning of protective coatings on new metal.

  Glass must be cleaned periodically to remove any film (which is a 

normal by-product of combustion) which may be visible. Film can 

easily be removed by removing the door, see 

Figure 11a - 11b

Handle the door carefully, and clean it with nonabrasive glass 

cleaners. One of the most effective products is Kel Kem.

  Silicone seals on inner door during initial firing will "off gas", leav

-

ing a visual deposit of a white substance on combustion cham-

ber walls. This can easily be removed using normal household 

products.

  Use a vacuum cleaner or whisk broom to keep the control com-

partment, burner, and firebox free from dust and lint.   

  The logs may be cleaned periodically with a vacuum to remove 

dirt, dust and other contaminates. If the logs shift during cleaning, 

refer to 

Figures 12a - 12c

 for proper positioning.

Содержание Hotshot DHS

Страница 1: ...rature Strong magnetic field Optical radiation Non ionizing radiation Radiation Hazardous to the Environment Danger of harming your hands Irritant Cutting Watch your step Slippery floor High temperatures Glass hazard Danger of suffocation High voltage Toxic Flammable materials Corrosive Fork lift trucks Danger overhead crane Explosion risk Oxidising Danger of death Biohazard Laser Radiation Danger...

Страница 2: ...s 6 Clearances 7 Installing the Gasline 7 Chimney Liner Installation 8 Face Plate Trim and Louvres Face Plate Installation 9 Lower Louvre Assembly 9 Face Plate Trim 9 Upper Louvre Assembly 10 Wiring for the Air Circulating Fan 11 Removing and Installing the Screen Door 12 Installing the Logset 13 Operation 14 15 Maintenance 16 17 Warranty 19 Appendix 20 ...

Страница 3: ...n a masonry fireplace equipped with a double burner glowing embers and a six piece log set The Hotshot DHS is rated for Natural Gas or Propane at 25 000 BTU H 7 4 Kilowatts We strongly encourage you to read and carefully follow the instruc tions laid out in this Installation Operation and Maintenance Manual and retain it for your future reference Pay special attention to all cautions warnings and ...

Страница 4: ...l etc It is imperativethat controlcompartments burnersand circulatingair passagewaysof the fireplace are kept clean NOTICE Installations in Canada must conform to the local codes or in the absence of local codes to the current version of Natural Gas and Propane Installation Code CSA B149 Electrical Installations must conform to the local codes or in the absence of local codes to the current versio...

Страница 5: ...Page 5 Hotshot Gas Fireplace Insert XG0511 150203 Installation Rating Plate Sample LBL1205 V6 1 Stand Pilot Screen DEC06 2014 Teklynx LabelView Demo ...

Страница 6: ...ions Figure 1b Deluxe Arched Faceplate dimensions Figure 1c Standard Faceplate dimensions 27 3 4 705 25 634 21 3 8 544 10 3 4 272 20 507 23 5 8 600 14 1 8 357 27 3 4 705 16 1 4 411 15 7 8 405 20 1 4 513 21 1 2 545 14 5 8 371 16 1 8 410 11 280 Top View Front View Side View Note Images are shown without screens for clar ity purposes However your fireplace should not be operated without proper instal...

Страница 7: ...ssure testing of that system at test pressures in excess of 1 2 psig 3 5 kPa The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psig 3 5 kPa Figure 3 Gas line location Note After the gas line is connected each appliance con nection val...

Страница 8: ...ssible into the fireplace open ing Reach inside the opening above the Hotshot and insert the vent connector into the slot at the back of the fireplace Push the connector slide back as far as it will go to secure the chimney liner in position See figure 5b Centre the Hotshot in the fireplace opening and connect the gas line See Figure 3 To install the face plate and louvres see Installing Face Plat...

Страница 9: ...ep 2 Install the Lower Louvre Assembly Position the Lower Louvre Assembly as shown in Figure 7 Line up the screw holes on the hinge with the pilot holes on the front of the fireplace and attach using three screws The lower louvres should rotate freely allowing easy access to the Hotshot control compartment Step 3 Install the Face Plate Trim To assemble the face plate trim slide the top end of the ...

Страница 10: ...the top rail and one screw into each of the side rails as shown in figure 8b To remove face plate or face plate trims simply reverse above procedures Figure 8b Installing the trim Figure 9a Installing the upper louvres Figure 9b Installing the upper louvres Raise the Upper Louvre over the heat deflector ensuring the heat deflector is positioned between the bottom and middle louvre Figure 9c Comple...

Страница 11: ...SA must be grounded in accordance with local codes or in the absence of local codes with the National Electrical Code ANSI NFPA 70 NOTE If any of the original wire supplied with the appliance is replaced it must be replaced with the same type or its equivalent Removing and Installing the Screen and Door Removing the screen and door Figure 11a Removing the screw covers G H N Motor Fuse Heat sensor ...

Страница 12: ...lass cleaner such as Kel Kem or White off NOTICE Installing the screen and door 1 Push the door up along the front of the firebox until the top edge of the door frame is underneath the Hotshot hood Line up the screw holes in the door with the corresponding holes on the front of the fireplace and attach with the four screws 2 Place screen over door and line up screw holes 3 Attach with four screws ...

Страница 13: ...the fireplace If the flame appears satisfactory replace the glass door and door cover Figure 12a Positioning for the top logs C and D Installing the Log Set Installing the Logs The double burner Hotshot is supplied with a six 6 piece fibre log set 1 Remove the door cover and the glass door Back log Left log Right log Front log Center logs Figure 12b Proper placement top view Back log Front log res...

Страница 14: ...turned from PILOT to OFF unless knob is pushed in slightly Do not force Standing Continuous Pilot Ignition SIT NOVA 820 with American Flame Electronic Ignition For Your Safety READ BEFORE LIGHTING If you cannot reach your gas supplier call the Fire Depart ment C Use only your hand to push in or turn the gas control knob Never use tools If the knob will not push in or turn by hand don t try to repa...

Страница 15: ...terclockwise Figure 13 Hi Lo Adjustment on the Hotshot inset s gas valve Fan Adjustment Turn the fan On Off Speed Control to On The Fan will turn on and off automatically depending on the appliance s temperature Adjust the fans speed by turning clockwise or counterclockwise See figure 13 WARNING Avoid contact with hot fireplace glass while adjusting burner Fan On Off Speed Control On Off Switch Fi...

Страница 16: ...ny part of the control system and any gas control which has been under water Cleaning WARNING Do not attempt to clean glass when hot Do not clean glass with abrasive materials as any glass etch ing may cause premature glass failure When the fireplace is first activated there may be some smoking and a visible film may be left on the glass This is a normal condition and is the result of burning of p...

Страница 17: ...lly slide the burner tray forward to remove You may need to disconnect the gas line to remove the burner 6 Carefully put the burner tray to the side Take care to not damage the pilot wires Figure 14b Figure 14c 7 Remove 10 screws holding down the fan cover access plate Figure 14d 8 Disconnect fan power Remove the screws holding down fan bracket 9 Reverse steps to reinstall Make sure to replace the...

Страница 18: ... Check wall switch for proper con nection 3 Check high limit switch If your fireplace still does not operate correctly consult your dealer or the manufacturer All service and repairs should be performed by a qualified agency All spare parts and optional such as trim finishes and the wireless infrared remote control are available from your local dealer or the manufacturer Replacement Parts Standing...

Страница 19: ...be subjected to normal use The Gas Appliances are designed to burn gas only Burning conventional fireplace fuels such as wood coal or any other solid fuel will cause damage to the Gas Appliance will produce excessive temperatures and will result in a fire hazard Limitations On Liability It is expressly agreed and understood that The Companies sole obligation and purchaser s exclusive remedy under ...

Страница 20: ...t of eight 8 feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS 4 INSPECTION The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve th...

Страница 21: ...Page 21 Hotshot Gas Fireplace Insert XG0511 150203 Notes ...

Страница 22: ...Ferndale Washington TF 1 800 789 6236 FX 1 866 3000 0927 Langley British Columbia TF 1 800 378 3115 FX 1 604 607 6462 XG0511 150203 Gas Fireplace Insert Hotshot ...

Отзывы: