![Montigo H38SVO-ST Series Скачать руководство пользователя страница 8](http://html.mh-extra.com/html/montigo/h38svo-st-series/h38svo-st-series_installation-and-maintenance-manual_1830624008.webp)
H*38VO-ST Outdoor Gas Fireplace
Page 8
XG0817 - 030412
WARNING!
Use Montigo Part No. #HSIT07 Water-tight electrical box, or
equivalent equipment. Ensure the box is installed in a
dry location
and avoid any moisture
.
If you install 115V Wire, ensure you use
Ground fault breakers
.
Also
avoid any moisture
near or around the 115V Circuit.
Installing The Remote Switch (H(L)VO-ST)
The
H38 SVO'
s gas valve, located behind the lower trim, may be
connected to a wall switch. The valve generates its own power on
a
millivolt circuit. Use only low voltage wire, and DO nOT
connect
any external power to it.
Refer to
Figure 4
for wiring requirements.
note:
The switch location must not exceed 30' from the fireplace.
Figure 7.
Wiring for the
H(L)38VO-ST (N,L)E
Honeywell gas control and pilot.
Figure 8.
Standing Pilot Diagram (H(L)38VO-ST)
Honeywell (Q3450)
Pilot Assembly
Pilot Electrical
Harness Connector
Honeywell Gas
Control (SV9501M)
Gas Control
Connector
Wall
Switch
Water tight
Electrical box
White
Black
Source 110V
Distribution
Panel
Power
Generator
Wall Switch
Manifold Pressure
Test Connection
Inlet Pressure
Pilot Adjsutment Screw
Installation