H*38VO-ST Outdoor Gas Fireplace
Page 6
XG0817 - 030412
Figure 3.
Framing dimensions (without Optional surround). Must be back-
framed as shown in Figure 2 below.
Installing The Fireplace
The fireplace may be installed in a location that maintains clearances to
ALL exterior furniture, appliances and other exterior equipment. Safety,
as well as efficiency of operation, must be considered when selecting
the fireplace location. Try to select a location that does not interfere with
foot traffic, has adequate ventilation, and offers an accessible pathway
for ventilated gasses.
Backframe Min. 38"
both sides Typical
41"
Surrounding construction
(bottom, sides and top) must
be non-combustible materials,
metal studs, concrete board
and concrete, brick, or stone.
Existing Co
mbustible Stru
ct
ur
e
40”
41”
23 7/8”
38”
36”
Combustible
materials
Backframe Min. 38"
both sides Typical
41"
Surrounding construction
(bottom, sides and top) must
be non-combustible materials,
metal studs, concrete board
and concrete, brick, or stone.
1" clearance
to corners only
1” Clearance to
combustibles to sides
ot Unit
Framing:
For Fireplace without the Optional Stainless steel
surround.
MODEL
Top
Header
Sides
Floor
Mantel
Ceiling
H*38VO-ST
36" 36" 12"
0"
24" 48"
Clearances
When installing a shelf over the top of the fireplaces, the following
guidelines must be adhered to:
Installation
Section 2: Framing