Divine Outdoor Gas Fireplace
Page 8
XG0150 - 140707.2
Installation
Section 4: Wiring
WARNING!
Montigo Part No. #RPOVO must be encased in a water-tight
electrical box OR ensure the box is installed in a dry location and
avoid any moisture. If installed outdoors, ensure you also install a
Ground Fault Interrupt per local code.
Installing The Remote Switch
The
Divine Outdoor'
s gas valve, located behind the lower trim, may
be connected to a wall switch. The valve generates its own power on
a millivolt circuit. Use only low voltage wire, and DO NOT
connect
any external power to it.
Refer to
Figure 4
for wiring requirements.
Note:
The switch location must not exceed 30' from the fireplace.
Figure 4.
Wiring for the
Divine Outdoor
VO Honeywell gas control and pilot.
Figure 4a.
Standing Pilot Diagram
Honeywell (Q3450)
Pilot Assembly
Pilot Electrical
Harness Connector
Honeywell Gas
Control (SV9501M)
Gas Control
Connector
Wall
Switch
Water tight
Electrical box
White
Black
Source 110V
Distribution
Panel
Power
Generator
Wall Switch
Manifold Pressure
Test Connection
Inlet Pressure
Pilot Adjsutment Screw