background image

Page 4

H-Series BF Gas Fireplace

Part No. XG0145

Installation

Vent  Installation

The 

H-Series BF

 is certified for use with standard 

4" B-Vent

 and requires 

no B-Vent appliance connector.  Simply attach the B-Vent to the fireplace 

flue collar, and secure it using 1/4" sheet metal screws.

Refer to the current 

CAN/CGA B-149.1

 and 

.2

 or 

ANSI Z223.1-1998 

Gas Installation Code

 for specific vent sizing.

Cautions: 

■ 

Test your B-Vent installation after completion to ensure that 

no combustible by products are spilling from the fireplaces 

opening.  This draft test should be performed after a three(3) 

minute warm up period.  The manufacturer will not be 

responsible for any installations with inadequate draw.

Installing The Gas Line

The gas line must be installed before finishing the H-Series BF Fireplace. 

Natural Gas

 requires a minimum  inlet gas supply  pressure of 5.5" W.C. 

& a manifold pressure of 3.5" W.C. 

Propane Gas

 requires a minimum 

inlet gas supply pressure of 11" W.C. & a manifold pressure of 10" W.C. 

Provision must also be made for a 1/8" N.P.T. plugged tapping and be 

accessible for test gauge connection immediately upstream of the gas 

supply  controls  to  the  appliance.  The  fireplace  gas  connection  and 

the main operating gas valve is located behind the removable trim at 

the bottom of the unit and need only be attached to the gas line  with 

an approved fitting, as required by the 

applicable installation codes

.

To access the fireplace gas connection the main burner must be 

removed as shown below in figure 4b.

• Only use gas shut-off valves approved for use by the state, province, 

region, or governing body, in which the appliance is being installed, or 

as required by the applicable installation codes.
• Flexible gas connectors must not exceed 3 feet in length, unless it is 

allowable  within applicable installation codes.

Note:

  After gas line is connected, 

each 

appliance connection

,

 

valve and valve train

 must be checked while under normal 

operating  pressure  with  either  a  liquid  solution,  or  leak 
detection device, to locate any source of leak. Tighten any 
areas  where  bubbling  appears  or  leak  is  detected  until 
bubbling stops completely or leak is no longer detected. 

DO  NOT use a flame of any kind to test for leaks.

Figure 4a.  

Gas line access.

The appliance and its individual shut-off valve must be disconnected 

from the gas supply piping system during any pressure testing of that 

system at test pressures in excess of 1/2 psig (3.5 kPa).
The appliance must be isolated from the gas supply piping system by 

closing its individual manual shut-off valve during any pressure testing 

of the gas supply piping system at test pressures equal to or less than 

1/2 psig (3.5 kPa).

Gasline Access

0.875” dia.

2” height

to center

7”

to center

Installing The Standoffs

To  avoid  elevated  mantel  temperatures,  all  H-Series  BF  gas 

fireplaces are required to have the supplied standoffs installed. 

The fireplace is supplied with two standoffs. Bend and install these 

standoffs on top of the fireplace ensuring that the height of the standoff 

maintains a 6" clearance.

Figure 5.

  

Installing the standoff's.

Burner Tray Gasket

Figure 4b.  

Gas line access.

Installing the Nailing Flange 

Extension 

H38BF

 

H42BF

Once the fireplace is placed into the framed opening, the supplied 

nailing extension must be placed along the top edge of the fireplace, 

and nailed in place to the framing, as illustrated below.

Figure 6.

  

Installing the Nailing Flange Extension.

Note:  

If more than 12 feet of B-Vent is used on the vent 

runs, use ceiling supports.

Note:  

Due to the top vent clearances to combustible 

materials there is no available shelf installation for 

the 

H-Series BF

 fireplaces.

Содержание H34BF

Страница 1: ...ht any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department For Your Safety Donotstoreorusegasoline or other flammable vapors and liquids in the vicinity of this or any other appliance Safety Notice Glass door...

Страница 2: ...he fireplace and or components including Direct Vent assembly or glass doors Use of any component part not manufactured or approved by Montigo in combination with this Montigo fireplace system Installation other than as instructed in this manual Consult your local Gas Inspection Branch on installation requirements for factory built gas fireplaces Installation repairs should be done by a qualified ...

Страница 3: ...ply to all dimensions except the framed opening where the clearance to combustibles is 0 The H Series BF clearances to combustible materials are H34BF H38BF H42BF Top Ceiling 8 Feet 8 Feet 8 Feet Back 2 2 2 Sides 1 1 1 Floor 0 0 0 Mantle 4 4 4 Flue 1 1 1 Clearance from the top of the fireplace to a combustible ceiling within the fireplace enclosure Refer to page 11 Unprotected combustible walls wh...

Страница 4: ...ceed 3 feet in length unless it is allowable within applicable installation codes Note After gas line is connected each appliance connection valve and valve train must be checked while under normal operating pressure with either a liquid solution or leak detection device to locate any source of leak Tighten any areas where bubbling appears or leak is detected until bubbling stops completely or lea...

Страница 5: ...because it will interfere with the access to retainers for removal of glass door Mantels Surrounds NOTE National Canadian Gas Association mantel test requirements are for fire hazard prevention to combustible materials New technology to meet consumer and government demands for the wise use of energy has prompted us to manufacture many models of fireplaces which are hot fuel and energy efficient Pl...

Страница 6: ...VAC 24VAC Grnd Screw Figure 9 Wiring for the H Series BF I with Honeywell gas control and pilot Gas Control and Pilot Wiring H Series BF A ADJ AUX Learn Remote Off Continuous Pilot Off On S I IPI POWER 6VAC 200mA AC ADAPTOR Wall Switch SWI Brown Brown Black White Green White Orange Pilot Main Manual Hi Lo Main Gas Input Main Gas Output White Sensor Orange Igniter Control Module Emergency Battery P...

Страница 7: ... the fan kit NOTE If any of the original wire supplied with the appliance is replaced it must be replaced with the same type or its equivalent Figure 12 Wiring schematic for optional fans Figure 11 Wiring for optional fans Removing and Installing the Door Removing the door The door is held in place by a lip on the top of the metal frame and two buckles at the bottom Release the buckles and lift th...

Страница 8: ...t Figure 14b Base log placement Figure14d Bottom left and right log placement Figure 14e Top left and right log placement Base Log Bottom Left Log Bottom Right Log Top Left Log Top Right Log Base Log Bottom Right Log Bottom Left Log Top Left Log Top Right Log 5 Start the fireplace If the flame appears satisfactory replace the glass door If the flame does not appear satisfactory double check the ai...

Страница 9: ...og placement 4 Arrange the ember chips on top of the burner tray the ember chips maybeplacedtocoverupto50 oftheburnerports burnerpattern However the chips must never be placed in a way that obstructs any of the six air inlet ports located at the rear of the burner as shown in figure 15d Air Inlet Ports Ember Chips 5 Place the top left log as shown in figure 15e 6 Place the top right log as shown b...

Страница 10: ...n Model H Series BF 3 Push in gas control knob slightly and turn clockwise to Off Do not force 4 Flip up the lower trim 1 Turn off remote switch 2 Flip down the lower trim 1 STOP Read the safety information above on this label 2 Flip down the lower trims 3 Push in gas control knob and turn clockwise to OFF 4 Wait five 5 minutes to clear out any gas Smell for gas including near the floor If you the...

Страница 11: ...ht any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions 1 Turn off remote switch 2 Flip down the lower trim 3 Turn the switch on the gas control to Off 4 Flip up the trim 1 STOP Read the safety information above on this label 2 Flip down the lower trims 3 Turn switch...

Страница 12: ...module will attempt to light the pilot until it detects that the pilot has been successfully lit 4 With the control module set to Continuous Pilot Off wait 5 minutes to clear out any gas If you smell gas STOP Follow B in the safety information above on this label If you don t smell gas go to the next step 5 Turn switch on the control module to Continuous Pilot On This will initiate the lighting of...

Страница 13: ...s equipped with an adjustable burner allowing you to raise or lower the flames To adjust the flames locate the black knob marked Hi Lo in the centre of the gas control valve See Figure 16 The front burners are not adjustable To raise the flame height turn the black knob located behind the lower trim counter clockwise To lower the flame height turn clockwise Figure 16a Hi Lo Adjustment on the H Ser...

Страница 14: ...re available from your local dealer or the manufacturer HONEYWELL SV 9500 SV9600 TroubleshootingSequence NOTE Before Troubleshooting Familiarize Yourself With The Startup And Checkout Procedure T urnG asSup p lyo ff Settherm o statto callfo rheat SV9500 SV9600 isp o w ered 24VA Cno m inal NO NO NO NO NO YES YES YES YES YES YES YES NO NO NO START Ig niterw arm sup andg lo w sred Pilo tValveo p ens ...

Страница 15: ...normal use The Gas Appliances are designed to burn gas only Burning conventional fireplace fuels such as wood coal or any other solid fuel will cause damage to the Gas Appliance will produce excessive temperatures and will result in a fire hazard Limitations On Liability It is expressly agreed and understood that The Companies sole obligation and purchaser s exclusive remedy under this Warranty un...

Страница 16: ... for AF RPA033 RPA033 RPA033 NG Pilot HIS RPA03 RPA03 RPA03 LP Pilot HIS RPA04 RPA04 RPA04 Thermocouple SIT RTC182 RTC182 RTC182 Interrupted Thermocouple Block RGC2034 RGC2034 RGC2034 Burner NG SIT RBH34B01 RBH38B01 RBH42B01 Burner LPG RBH34B02 RBH38B02 RBH42B02 Burner NG AF RBH34B15 RBH38B15 RBH42B15 Burner LPG AF RBH34B16 RBH38B16 RBH42B16 Burner NG HIS RBH34B07 RBH38B07 RBH42B07 Burner LPG HIS ...

Страница 17: ...Page 17 H Series BF Gas Fireplace Part No XG0145 Notes Notes ...

Страница 18: ...Canadian Heating Products Inc Langley BC V4W 4A1 Montigo Del Ray Corp Ferndale WA 98248 XG0150 ...

Отзывы: