background image

Page 11

H-Series BF Gas Fireplace

Part No. XG0145

For Your Safety - READ BEFORE LIGHTING:

To Turn Off Gas To Appliance:

Lighting  Instructions:

  If you cannot reach your gas supplier, call the Fire 

Department.

C.

  Use only your hand to push in or turn the gas control knob. 

Never use tools. If  the knob will not push in or turn by 
hand, don't try to repair it, call a qualified service technician. 
Force or attempt to repair may result in a fire or explosion.

D.

  Do not use this appliance if any part has been under water. 

Immediately call a qualified service technician to inspect 
the appliance and to replace any part of the control system, 
and any gas control which has been under water.

A. 

This appliance is equipped with an ignition system that 
lights the pilot burner automatically. 

Do not attempt to 

light the pilot by hand.

B.  BEFORE LIGHTING

 smell all around the appliance area for 

gas.  Be sure to smell next to the floor because some gas 
is heavier than air and will settle on the floor.

 

What To Do If You Smell Gas:

  Do not try to light any appliance.

  Do not touch any electrical switch; do not use any 

phone in your building.

  Immediately call your gas supplier from a neighbour's 

phone. Follow the gas supplier's instructions.

1. 

Turn off remote switch.

2. 

Flip down the lower trim.

3. 

Turn the switch on the gas control to "Off".

4. 

Flip up the trim.

1.

 

STOP!  

Read the safety information above on this label.

2.

  Flip down the lower trims.

3.

  Turn switch on the gas control to OFF".

4.

  Wait 5 minutes to clear out any gas.  If you smell gas,

 

STOP! 

Follow "B" in the safety information above on this 

label.  If you don't smell gas, go to the next step.

5.

  Turn switch on the gas control to "ON".

 NOTE:

 This unit is 

equipped with an ignition system that lights the pilot burner 
automatically. 

Do not attempt to light the pilot by hand.

6.

  Turn on wall switch.

7.

  Flip up the lower trim.

8.

  If the fireplace does not operate, follow the instructions "To 

Turn Off Gas To Appliance" and call your service technician 
or gas supplier.

with Honeywell  Electronic Ignition

Operation -  Model H-Series BF-I 

H-Series BF-I

Gas

Inlet

Gas Control Switch

Shown in "On" Position

WARNING:

 

If you do not follow these instructions exactly, a fire or explosion may 

result causing property damage, personal injury or loss of life.

Содержание H34BF

Страница 1: ...ht any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department For Your Safety Donotstoreorusegasoline or other flammable vapors and liquids in the vicinity of this or any other appliance Safety Notice Glass door...

Страница 2: ...he fireplace and or components including Direct Vent assembly or glass doors Use of any component part not manufactured or approved by Montigo in combination with this Montigo fireplace system Installation other than as instructed in this manual Consult your local Gas Inspection Branch on installation requirements for factory built gas fireplaces Installation repairs should be done by a qualified ...

Страница 3: ...ply to all dimensions except the framed opening where the clearance to combustibles is 0 The H Series BF clearances to combustible materials are H34BF H38BF H42BF Top Ceiling 8 Feet 8 Feet 8 Feet Back 2 2 2 Sides 1 1 1 Floor 0 0 0 Mantle 4 4 4 Flue 1 1 1 Clearance from the top of the fireplace to a combustible ceiling within the fireplace enclosure Refer to page 11 Unprotected combustible walls wh...

Страница 4: ...ceed 3 feet in length unless it is allowable within applicable installation codes Note After gas line is connected each appliance connection valve and valve train must be checked while under normal operating pressure with either a liquid solution or leak detection device to locate any source of leak Tighten any areas where bubbling appears or leak is detected until bubbling stops completely or lea...

Страница 5: ...because it will interfere with the access to retainers for removal of glass door Mantels Surrounds NOTE National Canadian Gas Association mantel test requirements are for fire hazard prevention to combustible materials New technology to meet consumer and government demands for the wise use of energy has prompted us to manufacture many models of fireplaces which are hot fuel and energy efficient Pl...

Страница 6: ...VAC 24VAC Grnd Screw Figure 9 Wiring for the H Series BF I with Honeywell gas control and pilot Gas Control and Pilot Wiring H Series BF A ADJ AUX Learn Remote Off Continuous Pilot Off On S I IPI POWER 6VAC 200mA AC ADAPTOR Wall Switch SWI Brown Brown Black White Green White Orange Pilot Main Manual Hi Lo Main Gas Input Main Gas Output White Sensor Orange Igniter Control Module Emergency Battery P...

Страница 7: ... the fan kit NOTE If any of the original wire supplied with the appliance is replaced it must be replaced with the same type or its equivalent Figure 12 Wiring schematic for optional fans Figure 11 Wiring for optional fans Removing and Installing the Door Removing the door The door is held in place by a lip on the top of the metal frame and two buckles at the bottom Release the buckles and lift th...

Страница 8: ...t Figure 14b Base log placement Figure14d Bottom left and right log placement Figure 14e Top left and right log placement Base Log Bottom Left Log Bottom Right Log Top Left Log Top Right Log Base Log Bottom Right Log Bottom Left Log Top Left Log Top Right Log 5 Start the fireplace If the flame appears satisfactory replace the glass door If the flame does not appear satisfactory double check the ai...

Страница 9: ...og placement 4 Arrange the ember chips on top of the burner tray the ember chips maybeplacedtocoverupto50 oftheburnerports burnerpattern However the chips must never be placed in a way that obstructs any of the six air inlet ports located at the rear of the burner as shown in figure 15d Air Inlet Ports Ember Chips 5 Place the top left log as shown in figure 15e 6 Place the top right log as shown b...

Страница 10: ...n Model H Series BF 3 Push in gas control knob slightly and turn clockwise to Off Do not force 4 Flip up the lower trim 1 Turn off remote switch 2 Flip down the lower trim 1 STOP Read the safety information above on this label 2 Flip down the lower trims 3 Push in gas control knob and turn clockwise to OFF 4 Wait five 5 minutes to clear out any gas Smell for gas including near the floor If you the...

Страница 11: ...ht any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions 1 Turn off remote switch 2 Flip down the lower trim 3 Turn the switch on the gas control to Off 4 Flip up the trim 1 STOP Read the safety information above on this label 2 Flip down the lower trims 3 Turn switch...

Страница 12: ...module will attempt to light the pilot until it detects that the pilot has been successfully lit 4 With the control module set to Continuous Pilot Off wait 5 minutes to clear out any gas If you smell gas STOP Follow B in the safety information above on this label If you don t smell gas go to the next step 5 Turn switch on the control module to Continuous Pilot On This will initiate the lighting of...

Страница 13: ...s equipped with an adjustable burner allowing you to raise or lower the flames To adjust the flames locate the black knob marked Hi Lo in the centre of the gas control valve See Figure 16 The front burners are not adjustable To raise the flame height turn the black knob located behind the lower trim counter clockwise To lower the flame height turn clockwise Figure 16a Hi Lo Adjustment on the H Ser...

Страница 14: ...re available from your local dealer or the manufacturer HONEYWELL SV 9500 SV9600 TroubleshootingSequence NOTE Before Troubleshooting Familiarize Yourself With The Startup And Checkout Procedure T urnG asSup p lyo ff Settherm o statto callfo rheat SV9500 SV9600 isp o w ered 24VA Cno m inal NO NO NO NO NO YES YES YES YES YES YES YES NO NO NO START Ig niterw arm sup andg lo w sred Pilo tValveo p ens ...

Страница 15: ...normal use The Gas Appliances are designed to burn gas only Burning conventional fireplace fuels such as wood coal or any other solid fuel will cause damage to the Gas Appliance will produce excessive temperatures and will result in a fire hazard Limitations On Liability It is expressly agreed and understood that The Companies sole obligation and purchaser s exclusive remedy under this Warranty un...

Страница 16: ... for AF RPA033 RPA033 RPA033 NG Pilot HIS RPA03 RPA03 RPA03 LP Pilot HIS RPA04 RPA04 RPA04 Thermocouple SIT RTC182 RTC182 RTC182 Interrupted Thermocouple Block RGC2034 RGC2034 RGC2034 Burner NG SIT RBH34B01 RBH38B01 RBH42B01 Burner LPG RBH34B02 RBH38B02 RBH42B02 Burner NG AF RBH34B15 RBH38B15 RBH42B15 Burner LPG AF RBH34B16 RBH38B16 RBH42B16 Burner NG HIS RBH34B07 RBH38B07 RBH42B07 Burner LPG HIS ...

Страница 17: ...Page 17 H Series BF Gas Fireplace Part No XG0145 Notes Notes ...

Страница 18: ...Canadian Heating Products Inc Langley BC V4W 4A1 Montigo Del Ray Corp Ferndale WA 98248 XG0150 ...

Отзывы: