EDVWSPV Horizontal Power Vent System

Part No. XG1303 - 120110

Appendix A - Termination Locations

A =  clearance to the termination frame above grade, veranda, porch, deck, or balcony 

[30 inches (75 cm) minimum] 

B =  clearance to door, or sides and top of window, that may be opened [30 inches (75 

cm) minimum for appliances.

C =  clearance to bottom of  window that may be opened horizontally [36 inches (92 cm) 

minimum for appliances.

D =  no clearance to permanently closed window when installed with approved glass 

penetration termination

E =  clearance to permanently closed  window [30 inches 75 cm recommended to prevent 

condensation on window]

F = 

distance of [30 inches 75 cm] from the centreline of the termination [30 inches (75 

cm) minimum]

G = 

[30 inches (75 cm) minimum to combustibles]

H =  clearance to outside corner [30 inches (75 cm) minimum]
I =  clearance to inside corner [30 inches (75 cm) minimum]
J =  *  not  to  be  installed  above  a  meter/regulator  assembly  within 

40" (103 cm) horizontally from the centreline of the regulator

K =  clearance to service regulator vent outlet [3 feet  minimum in the United States] [*6 

feet  (1.8 m) minimum in Canada]

=  clearance to non-mechanical air supply inlet to building or the combustion air inlet 

to any other appliance [16 inches (41 cm) minimum for appliances 

100 000 BTU/H 

(30kW)]

M =  clearance to mechanical air supply inlet [*6 feet  (1.8 m) minimum]

N = 

 clearance above paved sidewalk or a paved driveway located on public property 

[*7 feet (2.1 m) minimum]

P =  clearance under veranda, porch, deck, or balcony [30 inches (75 cm) minimum

 to 

non-combustibles] [30 inches (75 cm) minimum

 to combustibles]

Q =  clearance above a roof [24 inches (61 cm) minimum]
R =  clearance to adjacent walls and neighboring buildings [30 inches (75 cm) minimum]
S =  clearance from corner in recessed location [30 inches (75 cm) minimum]
T =  maximum depth in recessed location [48 inches (122 cm) minimum]
U =  minimum width for back wall of recessed location [60 inches (150 cm) minimum]
V =  [30 inches (75 cm) minimum] horizontal clearance between the frames of two 

terminations that are level.

W =  horizontal clearance between the frames of two terminations that are not level.  [30 

inches (75 cm) minimum]

 

a vent shall not terminate directly above a sidewalk or paved driveway which is 

located between two single family dwellings and serves both dwellings

  

only permitted if veranda, porch, deck, or balcony has an open side that is equal 

to or greater than the depth of the enclosed area

*  

require different clearance.

Содержание EDVWSPV47

Страница 1: ...ce has been turned off Safety screens are available and can reduce the risks of severe burns Please keep children away from the fireplace at all times Warning Improperinstallation adjustment alteration serviceormaintenancecancause injury or property damage Refer to this manual For assistance or additional information consult a qualified installer service agency or the gas supplier Warning What to ...

Страница 2: ...ddress practices not related to personal injury Table Of Contents Important All dimensions and design specifications are subject to approval upon quotation of fire place and associated equipment Congratulations Safety Alert Key Table of Contents 2 Specifications 2 Introduction 3 Dimensions 4 5 Installation General Information 6 Selecting and Installing the Fireplace 6 Vent Installation 6 Power Ven...

Страница 3: ...l Information This installation guide covers installation of the External Power Vent System only This system is designed to allow installation of gas fire places that cannot be done with a standard Direct Vent gas fireplace installation Also read through the fireplace s Installation Operation and Mainte nance Instructions as it must also be adhered to Power Cord Harnesses EPVH10 10 foot power cord...

Страница 4: ...Power Vent System Part No XG1303 120110 Dimensions 9 3 4 REF 11 1 16 11 1 16 9 3 4 10 9 16 4 9 0 Dimensions EDVWSPV47 Dimensions EPVF47 mounting frame for EDVWSPV47 14 1 4 14 1 16 12 1 8 1 1 2 7 9 11 16 4 9 16 12 5 16 4 9 11 16 ...

Страница 5: ...Vent System Part No XG1303 120110 9 3 4 10 9 16 5 9 0 11 1 16 11 1 16 11 1 16 10 9 16 5 9 0 Dimensions Dimensions EDVWSPV58 Dimensions EPVF58 mounting frame for EDVWSPV58 14 1 4 14 1 16 1 1 2 4 9 16 8 12 1 8 9 11 16 12 5 16 4 9 11 16 ...

Страница 6: ...installations are only possible with gas fireplaces equipped with Electronic or Hot Surface Ignition HSI H V Elbow 1 Elbow 2 Elbow 3 Elbow 5 Elbow 4 Elbow 6 H3 H2 H1 V1 V2 V3 H2 H1 V D Installing the Power Vent Figure 4 Framing the Opening for Power Vent Selecting A Termination Location Before installing the termination ensure that the proper air flow restrictor is installed as shown on page 5 and...

Страница 7: ...embled Rough in Kit Step 7 Fasten Conduit mounting frame into place using existing hard ware 6 pcs Coil conduit in behind cover Step 8 Install the Power Vent Power communication harness Hold the Power Vent in close proximity of the assembled Rough in Kit and plug in the Power Vent communication Power Cord Note the direction and orientation of the pins inside the Power Vent connector snap together ...

Страница 8: ...nd it must be at least 1 clear of all venting 1 min Vent Cable Figure 12 Wiring Diagram for Power Vent System Control Cable Installation for Vertical Termination EXPVH 10 100 Honeywell SV9501M PPO Box Power Vent EDVRP47 PVFCB ECB005 Pilot Inside Fireplace Wall Switch 120V Step 10 Completed installation Step 9 Install the Power Vent Place the Power Vent into the Rough in frame aligning the Power Ve...

Страница 9: ...m Part No XG1303 120110 Installation WARNING If you do not follow these instructions exactly a fire or explosion may result causing property damage personal injury or loss of life Figure 13 Standard ECB006 Wiring Schematic for Power Vent System ...

Страница 10: ...ected to normal use The Gas Appliances are designed to burn gas only Burning conventional fireplace fuels such as wood coal or any other solid fuel will cause damage to the Gas Appliance will produce excessive temperatures and will result in a fire hazard Limitations On Liability It is expressly agreed and understood that The Companies sole obligation and purchaser s exclusive remedy under this Wa...

Страница 11: ...ce to non mechanical air supply inlet to building or the combustion air inlet to any other appliance 16 inches 41 cm minimum for appliances 100 000 BTU H 30kW M clearance to mechanical air supply inlet 6 feet 1 8 m minimum N clearance above paved sidewalk or a paved driveway located on public property 7 feet 2 1 m minimum P clearance under veranda porch deck or balcony 30 inches 75 cm minimum to n...

Страница 12: ...12 EDVWSPV Horizontal Power Vent System Part No XG1303 120110 EDVWSPV58 Horizontal Power Vent Detail Front View 30 Min 30 Min Eaves Overhang Wall F G H I 30 75cm Min V Appendix A Termination Locations cont d ...

Страница 13: ... directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS 4 INSPECTION The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless upon in...

Страница 14: ...Page 14 EDVWSPV Horizontal Power Vent System Part No XG1303 120110 Notes ...

Страница 15: ...Page 15 EDVWSPV Horizontal Power Vent System Part No XG1303 120110 Notes ...

Страница 16: ...Canadian Heating Products Inc Langley BC V4W 4A1 Montigo Del Ray Corp Ferndale WA 98248 XG1303 062010 f i r e f e a t u r e www montigo com ...

Отзывы: