Montigo EDVWSPV47 Скачать руководство пользователя страница 10

Page 10

EDVWSPV Horizontal Power Vent System

Part No. XG1303 - 120110

The Warranty

The Companies warrants the Montigo Gas Appliance to be free from defects in materials and workmanship at the time of manufacture. On the Montigo, there is a 

ten-year warranty on the firebox and its components, a five-year warranty on the main burner, and a one-year warranty on the pilot burner, gas control valve and 

fibre logs. Glass, plated/painted finishes, and refractory lining are exempt.

Remedy And Exclusions

The coverage of this Warranty is limited to all components of the Gas Appliance manufactured by The Companies.
This Warranty only covers Montigo Gas Appliances installed in the United States or Canada.
If the components of the Gas Appliance covered by this Warranty are found to be defective within the time frame stated (see The Companies right of investigation 

outlined below). The Companies will, at its option, replace or repair defective components of the Gas Appliance manufactured by The Companies at no charge, 

and will also pay for reasonable labour costs incurred in replacing or repairing components. If repair or replacement is not commercially practical, The Companies 

will, at its option, refund the purchase price of the Montigo Gas Appliance. 
This Warranty covers only parts and labour as provided above. In no case shall The Companies be responsible for materials, components, or construction which 

are not manufactured or supplied by The Companies, or for the labour necessary to install, repair or remove such materials, components or construction. All 

replacement or repair components will be shipped F.O.B. the nearest The Companies factory. 

Qualifications To The Warranty

The Gas Appliance Warranty outlined above is further subject to the following qualifications:
(1)  The Gas Appliance must be installed in accordance with The Companies installation instructions and local building codes. The Warranty on this Montigo Gas 

Appliance covers only the component parts manufactured by The Companies. The use of components manufactured by others with this Montigo Gas Appliance 

could create serious safety hazards, may result in the denial of certification by recognized national safety agencies, and could be in violation of local building 

codes. This warranty does not cover any damages occurring from the use of any components not manufactured or supplied by The Companies 

(2)  The Montigo Gas Appliance must be subjected to normal use. The Gas Appliances are designed to burn gas only. Burning conventional fireplace fuels such 

as wood, coal or any other solid fuel will cause damage to the Gas Appliance, will produce excessive temperatures and will result in a fire hazard.

Limitations On Liability

It is expressly agreed and understood that The Companies sole obligation, and purchaser's exclusive remedy under this Warranty, under any other warranty, 

expressed or implied, or in contract, tort or otherwise, shall be limited to replacement, repair, or refund, as specified above.
In no event shall The Companies be responsible for any incidental or consequential damages caused by defects in its products, whether such damage occurs 

or is discovered before or after replacement or repair, and whether or not such damage is caused by The Companies negligence. Some states do not allow the 

exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. The duration of any implied warranty 

with respect to this Montigo Gas Appliance is limited to the duration of the foregoing warranty. Some states do not allow limitation on how long an implied warranty 

lasts, so the above may not apply to you.

Investigation Of Claims Against Warranty

The Companies reserves the right to investigate any and all claims against this Warranty and to decide upon method of settlement.
The Companies Are Not Responsible For Work Done Without Written Consent
The Companies shall in no event be responsible for any warranty work done without first obtaining The Companies written consent.
Dealers Have No Authority To Alter This Warranty
The Companies employees and dealers have no authority to make any warranties nor to authorize any remedies in addition to or inconsistent with those stated above.

How To Register A Claim Against Warranty

In order for any claim under this Warranty to be valid, The Companies must be notified of the claimed defect in writing or by telephone, as soon as reasonably 

possible after the defect is discovered. Claims against this Warranty in writing should include the date of installation, and a description of the defect.

Other Rights

This Warranty gives you specific legal rights, and you may also have other rights which vary from state to state.

NOTE:

 

The Companies

 as stated above refer to - Canadian Heating Products Inc. and/or Montigo Del Ray Corp.

Canadian Heating Products Inc. and/or Montigo DelRay Corp. reserves the right to make changes at any time, without notice, in design, 

materials, specifications, prices and also to discontinue colors, styles and products.

Warranty

Содержание EDVWSPV47

Страница 1: ...ce has been turned off Safety screens are available and can reduce the risks of severe burns Please keep children away from the fireplace at all times Warning Improperinstallation adjustment alteration serviceormaintenancecancause injury or property damage Refer to this manual For assistance or additional information consult a qualified installer service agency or the gas supplier Warning What to ...

Страница 2: ...ddress practices not related to personal injury Table Of Contents Important All dimensions and design specifications are subject to approval upon quotation of fire place and associated equipment Congratulations Safety Alert Key Table of Contents 2 Specifications 2 Introduction 3 Dimensions 4 5 Installation General Information 6 Selecting and Installing the Fireplace 6 Vent Installation 6 Power Ven...

Страница 3: ...l Information This installation guide covers installation of the External Power Vent System only This system is designed to allow installation of gas fire places that cannot be done with a standard Direct Vent gas fireplace installation Also read through the fireplace s Installation Operation and Mainte nance Instructions as it must also be adhered to Power Cord Harnesses EPVH10 10 foot power cord...

Страница 4: ...Power Vent System Part No XG1303 120110 Dimensions 9 3 4 REF 11 1 16 11 1 16 9 3 4 10 9 16 4 9 0 Dimensions EDVWSPV47 Dimensions EPVF47 mounting frame for EDVWSPV47 14 1 4 14 1 16 12 1 8 1 1 2 7 9 11 16 4 9 16 12 5 16 4 9 11 16 ...

Страница 5: ...Vent System Part No XG1303 120110 9 3 4 10 9 16 5 9 0 11 1 16 11 1 16 11 1 16 10 9 16 5 9 0 Dimensions Dimensions EDVWSPV58 Dimensions EPVF58 mounting frame for EDVWSPV58 14 1 4 14 1 16 1 1 2 4 9 16 8 12 1 8 9 11 16 12 5 16 4 9 11 16 ...

Страница 6: ...installations are only possible with gas fireplaces equipped with Electronic or Hot Surface Ignition HSI H V Elbow 1 Elbow 2 Elbow 3 Elbow 5 Elbow 4 Elbow 6 H3 H2 H1 V1 V2 V3 H2 H1 V D Installing the Power Vent Figure 4 Framing the Opening for Power Vent Selecting A Termination Location Before installing the termination ensure that the proper air flow restrictor is installed as shown on page 5 and...

Страница 7: ...embled Rough in Kit Step 7 Fasten Conduit mounting frame into place using existing hard ware 6 pcs Coil conduit in behind cover Step 8 Install the Power Vent Power communication harness Hold the Power Vent in close proximity of the assembled Rough in Kit and plug in the Power Vent communication Power Cord Note the direction and orientation of the pins inside the Power Vent connector snap together ...

Страница 8: ...nd it must be at least 1 clear of all venting 1 min Vent Cable Figure 12 Wiring Diagram for Power Vent System Control Cable Installation for Vertical Termination EXPVH 10 100 Honeywell SV9501M PPO Box Power Vent EDVRP47 PVFCB ECB005 Pilot Inside Fireplace Wall Switch 120V Step 10 Completed installation Step 9 Install the Power Vent Place the Power Vent into the Rough in frame aligning the Power Ve...

Страница 9: ...m Part No XG1303 120110 Installation WARNING If you do not follow these instructions exactly a fire or explosion may result causing property damage personal injury or loss of life Figure 13 Standard ECB006 Wiring Schematic for Power Vent System ...

Страница 10: ...ected to normal use The Gas Appliances are designed to burn gas only Burning conventional fireplace fuels such as wood coal or any other solid fuel will cause damage to the Gas Appliance will produce excessive temperatures and will result in a fire hazard Limitations On Liability It is expressly agreed and understood that The Companies sole obligation and purchaser s exclusive remedy under this Wa...

Страница 11: ...ce to non mechanical air supply inlet to building or the combustion air inlet to any other appliance 16 inches 41 cm minimum for appliances 100 000 BTU H 30kW M clearance to mechanical air supply inlet 6 feet 1 8 m minimum N clearance above paved sidewalk or a paved driveway located on public property 7 feet 2 1 m minimum P clearance under veranda porch deck or balcony 30 inches 75 cm minimum to n...

Страница 12: ...12 EDVWSPV Horizontal Power Vent System Part No XG1303 120110 EDVWSPV58 Horizontal Power Vent Detail Front View 30 Min 30 Min Eaves Overhang Wall F G H I 30 75cm Min V Appendix A Termination Locations cont d ...

Страница 13: ... directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS 4 INSPECTION The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless upon in...

Страница 14: ...Page 14 EDVWSPV Horizontal Power Vent System Part No XG1303 120110 Notes ...

Страница 15: ...Page 15 EDVWSPV Horizontal Power Vent System Part No XG1303 120110 Notes ...

Страница 16: ...Canadian Heating Products Inc Langley BC V4W 4A1 Montigo Del Ray Corp Ferndale WA 98248 XG1303 062010 f i r e f e a t u r e www montigo com ...