background image

11/93

Page 8 of 13

FIGURE 14.  ROBERT SHAW GAS CONTROL VALVE

FOR ALTERNATE
GAS VALVE SEE
FIGURE 16 ON THE
NEXT PAGE.

Lift panel upwards
and outwards until
panel releases from
mounting pins.

Easily removed for cleaning and servicing.  Although this pane is
made of a very tough tempered glass, always handle it carefully and
place in a safe location where it will not be broken or damaged.

To remove the outer glass panel lift upwards and outwards.  This will
release the panel from the mounting pins.  See Figure 11.

   REMOVAL OF INNER DOOR

To remove inner glass door, outer glass door must first be removed.
Next turn the safety door locks outwards as illustrated in Figure 12.
Note:
 When turning and unlocking the safety door locks a small
additional pressure is required to start the unlocking procedure.
This is because a latch pin of the safety door lock is seated into a latch
plate notch (see Figure 13).  This ensures the safety door lock is in
its correct position, maintaining the door seal is under constant
spring  pressure.

IMPORTANT: For your safety when replacing
inner door to its original position  always assure the
safety door latch pin is  correctly positioned with the
notch in the latch plate. (see Figure 13).

REMOVAL OF OUTER DOOR

FIGURE 11.    OUTER GLASS DOOR

  INSTALLING LOG SET

The Montigo 36DV-TV is supplied with four(4) very attractive
cultured oak logs.  To install simply place log “A’s” rectangular
shaped extension into the log rest  located on rear wall of the burner
assembly.  Place the slot of log “B” over the pilot runner bar located
on the left hand front side of the burner assembly. Next place logs
C” and “D” onto mating positions of  logs “A” and “B”, as shown
below.   FAILURE TO INSTALL LOGS AS INSTRUCTED MAY
RESULT IN EXCESSIVE SOOTING.

FIGURE 13.   SAFETY LOCK

Knotch

Door

Turn

Turn

FIGURE 12.    INNER GLASS DOOR

  LIGHTING PILOT AND MAIN BURNER

To light pilot it is necessary that you remove outer and inner glass

door (refer to sections on glass door removal). The gas control valve

is located behind the brass trim in the centre of the fireplace (see

Figure 14 below).  Before lighting the pilot, make sure that the gas

line is connected and the gas shut-off valve is turned to the ON

position. To light the pilot we recommend the use of a long  match

or removal of log“C”, “F”, “G”:

a) Partially depress and turn dial on gas control valve to “OFF”

position and wait 5 minutes.

b) Turn dial  to pilot position, depress dial and light pilot burner,

hold for1 minute, then release.  If pilot does not remain

ignited, repeat, allowing a longer time to elapse before

releasing dial.

c) Re-install inner and outer glass door.

NOTE: For your protection and safety, main gas burner can not

be activated until inner glass door has been re-installed to activate

a safety cut off switch.

d) To light the main burner, turn dial to “ON”, then turn on

remote switch.

e) Turn off flame with remote switch. For complete shut down,

slightly depress gas control valve dial and turn to “OFF”
position.

A

B

D

C

Control Valve

Wire to

wall switch

Содержание ECONO-PLUS 36DV-TV

Страница 1: ...R YOUR SAFETY IF YOU SMELL GAS 1 OPENWINDOWS DONOTSTOREORUSEANYFLAMMABLE 2 DON TTOUCHELECTRICALSWITCHES VAPOURSORLIQUIDSNEARTHISORANY 3 EXTINGUISHANYOPENFLAME OTHERGAS BURNINGAPPLIANCE 4 IMMEDIATELYCALLYOURGASSUPPLIER READ INSTRUCTIONS CAREFULLY BEFORE INSTALLING MODEL MONTIGO36DV TV CANADIAN HEATING PRODUCTS INC 12091 88th Avenue Surrey B C Canada Phone 604 597 3115 Fax 604 597 3096 ...

Страница 2: ... SEEFIGURE2FORFRAMINGDIMENSIONS FIGURE 1 FIREPLACE DIMENSIONS CAUTION The gas line must be installed before finishing the Montigo 36DV TV Fireplace Natural Gas requires an inlet pressure of 7 W C a manifold pressure of 3 5 W C Propane Gas requires an inlet pressure of 11 W C a manifold pressure of 10 5 W C It is also required that provisions be made for a 1 8 N P T plugged tapping and be accessabl...

Страница 3: ...mbustible materials Note It is imperative for satisfactory operation of the Montigo 36DV TV fireplace that no venting component be modified in any way All components have been manufactured to eliminate the need for modification when properly selected and installed CAUTIONS AND REQUIREMENTS DIRECT VENT TERMINATION LOCATION This section is used to determine where your direct vent termination will be...

Страница 4: ...ngth Maximum retracted length FIGURE 5 TYPICAL INSTALLATIONS Header 10 ft from center of elbow 12 1 2 ft from center of fireplace Stucco Can Vent Termination 3 ft flex section B Solid section includes 90 degree elbow Hearth Wall Thickness 4 12 A FIGURE 6 EXTENDED 10 SECTION 7 1 2 ft from center of fireplace 3 ft flex section 10 ft from center of elbow A B Stucco Can Vent Termination Solid section ...

Страница 5: ... Plate Ring E 7 Firestop FS 7 7 Firestop F Roof Flashing MRF 16 1 12 to 6 12 pitch MRF 12 6 12 to 12 12 pitch VERTICAL DIRECT VENT TERMINALS Shall not be installed Less than two feet above the highest point where vent passes through the roof Less than six feet from a mechanical air inlet Less than three feet from a parapet wall Offsets A maximum of two offsets with 90 degree bends may be made and ...

Страница 6: ...nlets A B C Horizontal Vertical VENTING GRAPH VENTING GRAPH Venting graph is used for top vent direct vent model only How to use the venting graph 1 Determine the height for the centre of the 7 vent elbow and mark a horizontal line until it intersects with the slanted graph line 2 From the point of this intersection draw a vertical line to the bottom line of the graph 3 Select the indicated dimens...

Страница 7: ...combustion door NOTE National Canadian Gas Association mantel test require ments are for fire hazard prevention to combustible materials New technology to meet consumer and government demands for the wise use of energy has prompted us to manufacture many models of fireplaces which are hot fuel and energy efficient Please be aware temperatures over the mantel will rise above normal room temperature...

Страница 8: ...lar shaped extension into the log rest located on rear wall of the burner assembly Place the slot of log B over the pilot runner bar located on the left hand front side of the burner assembly Next place logs C and D onto mating positions of logs A and B as shown below FAILURETOINSTALLLOGSASINSTRUCTEDMAY RESULTINEXCESSIVESOOTING FIGURE 13 SAFETY LOCK Knotch Door Turn Turn FIGURE 12 INNER GLASS DOOR...

Страница 9: ...ust be cleaned periodically Film can easily be removed by removing inner and outer doors handling carefully and cleaning with normal liquid household products WARNING Do not attempt to clean glass when hot Do not clean glass with abrasive materials as any glass etching may cause premature glass failure Silicone seals on inner door during initial firing will off gas leaving a visual deposit of a wh...

Страница 10: ...se The decorative gas appliances are designed to burn gas only Burning conventional fireplace fuels such as wood coal or any other solid fuel will cause damage to the decorative gas appliance will produce excessive temperatures and will result in a fire hazard LIMITATIONS ON LIABILITY It is expressly agreed and understood that Canadian Heating Products Inc s sole obligation and purchaser s exclusi...

Отзывы: