C38-DV Gas Fireplace

Part  No.  XG0118C

Installation

NOTES

:

n

If logs are not placed properly, excessive sooting will result.

n

The  surface  of  the  logs  will  crack  due  to  the  heat  from  the

flames. This is a normal occurance.

Embers

Log 'D'

Log 'E'

Flame Shaper

Log  'A'

Log  'C'

Log  'B'

Figure  23c.

    Removing  the  door.

Re-installing the door:

To re-install the door, tilt the top edge towards you and line up the tabs
of the bottom of the door with the slots on the fireplace. Place the tabs
into the slots, and tilt the top of the door back towards the fireplace as
far as it will go. Close the latches by hooking Part B onto the groove at
the top of the door and pushing Part A down completely.

Figure 25.

  Installing the horizontal trim pieces.

Installing the Trim & Baffle

The fireplace is shipped with 6 horizontal trim pieces (3 upper and 3
lower), which must be field-installed.

Install the trim by placing the top edge of the trim over to the
retainer  clips  on  either  side  of  the  fireplace.  Push  the  bottom  edge
firmly inwards and the trim will snap on. 

 (See figure 25) 

Remember to

slide the baffle into the top trim piece 

.

 

(See Inset)

Note: Baffle should rest on top of the tabs.

Inset. 

Slide in baffle

before installing top trim.

Installing the Log Set

Installing the Logs:

The C38-DV is supplied with five ceramic fibre logs. Unpack the logs
and handle them very carefully.

1.

Remove the door cover and the glass door.

2.

Place the Back log onto the back log rest as shown below in figure
24a. The log has lip on the bottom which fits into the slot on the log rest.

3.

Place the Front log onto the front log rest as shown in figure 24a.
Center the log from side to side, and push it against the back of
the log rest. Carefully push the log onto the metal spikes on the log rest.

4.

Place the top logs in position as shown in figure 24b, place the
centre log down first, then the right and left logs.

5.

Start the fireplace. If the flame appears satisfactory, replace the
glass door and door cover.

Figure 24a.

Positioning for the front and back logs.

Figure 24b.

Proper log placement.

Содержание C38-DV

Страница 1: ...your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Warning Improper installation adjustment alteration serv...

Страница 2: ...o the current CAN CGA B 149 1 and 2 Gas Installation Code and local regulations If the optional air circulatingfankitisinstalled itmustbeelectricallygroundedin accordance with CSA C22 1 Canadian Elect...

Страница 3: ...Vent Rear Vent Figure 3 Corner framing dimensions Figure 2 Framing dimensions When sheetrock is not used behind the fireplace framing depth may be reduced to 16 7 8 Framing WARNING When this appliance...

Страница 4: ...ne Gas requires a minimum inlet gas supply pressure of 11 W C a manifold pressure of 10 W C Provision must also be made for a 1 8 N P T plugged tappingandbeaccessiblefortestgaugeconnectionimmediately...

Страница 5: ...1 Frame the termination opening to 12 x 12 2 Fasten the MOSR frame to the interior side of the studs using a minimum of 4 screws 3 Insert the termination into the MOSR frame as shown here and attach...

Страница 6: ...lation If the vertical dimension from the floor of the fireplace is 72 and the horizontal run to the wall flange of the vent termina tion is 84 this would NOT be an acceptable installation Figure 7 Ve...

Страница 7: ...Figure 10 and 11 C flex sections and D rigid sections may be used in conjunction with oneanothertoobtaindifferentpossiblehorizontallengthinstallations NOTE Flex section with no vertical rise must not...

Страница 8: ...required adaptor n A maximum of two offsets each offset has two 90 bends may be madeandshallnotexceedtotallengthof25 oftheverticalventheight when measured center to center of piping Example Typicalve...

Страница 9: ...supplied with a 20 extension pipe PXT 20 with female female connections For shorter installations cut the PXT 20 to the desired length For extended installations use the PXT 20 section as supplied fo...

Страница 10: ...tical dimension from the hearth is 90 and the horizontal run to the wall flange of the vent termination is 126 this would be an acceptable installation Example C Unacceptable Installation If the verti...

Страница 11: ...ntel hearth or surround New technology to meet consumer and government demands for the wise use of energy has prompted us to manufacture many models of fireplaces which are hot fuel and energy efficie...

Страница 12: ...t plug to motor Wiring for the optional Fan Kit All C38 DV fireplaces may be equipped with optional fan kits Part no RFK1001 RFK1003 RFK1006 or RFK1007 for circulating heat into the living space Insta...

Страница 13: ...he trim over to the retainer clips on either side of the fireplace Push the bottom edge firmly inwards and the trim will snap on See figure 25 Remember to slide the baffle into the top trim piece See...

Страница 14: ...el C38 DV 3 Push in gas control knob slightly and turn clockwise to Off Do not force 4 Flip up the lower trim 1 Turn off remote switch 2 Flip down the lower trim 1 STOP Read the safety information abo...

Страница 15: ...ight any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions 1 Turn of...

Страница 16: ...ing Instructions See pages 14 and 15 Burner Adjustment TheC38 DV millivoltmodelonly isequippedwithanadjustable burner allowingyoutoraiseorlowertheflames Toadjusttheflames locatetheblackknobmarked Hi L...

Страница 17: ...t your dealer or the manufacturer All service and repairs should be performed by a qualified agency All spare parts optional fans and optional trim finishes are available from your local dealer or the...

Страница 18: ...ultinafirehazard Limitations On Liability Limitations On Liability Limitations On Liability Limitations On Liability Limitations On Liability ItisexpresslyagreedandunderstoodthatTheCompaniessoleobliga...

Страница 19: ...ited States 6 feet 1 8 m minimum in Canada L clearance to nonmechanical air supply inlet to building or the combustion air inlet to any other appliance 16 inches 41 cm minimum for appliances 100 000 B...

Страница 20: ...Canadian Heating Products Inc Langley BC V4W 4A1 Montigo Del Ray Corp Ferndale WA 98248 XG0118C Rev 00 04 03...

Отзывы: