Figure 11 Sec.6
Figure 7 Sec.6
6). Unplug the cable that runs from the stepper motor to the control
board and remove it from in between the control board mounting
bracket and the fireplace.
Figure 12 Sec.6
7). Place the LP stepper motor onto the valve being extremely
careful that the orientation of the regulator is correct.
8). Reinstall the 2 screws supplied with the conversion kit to fasten
the stepper motor to the valve body.
Figure 8 Sec.6
9). Attach the label provided to the side of the valve body. This
label shows that the valve has been converted using SIT approved
components.
Figure 9 Sec.6
10). Run the cable from the stepper motor in between the control
mounting bracket and fireplace.
Figure 10 Sec.6
12). Plug the cable into the control board.