M-9
Starting
The blowers must be operated for a minimum of four minutes before each time the engine
is started. Failure to operate the blower can cause an explosion.
1. Operate the ventilation blowers for a minimum of four minutes and check the engine compartment for
gasoline vapors.
Do not crank the engine for more that seven seconds at a time. Allow a five second cool
down period between cranking attempts if the engine fails to start. If the engine fails to
start after three attempts , contact an authorized dealer for repairs. Failure to do so may
result in serious damage to the starter motor.
2. Press the controller master switch, or the remote start switch on the AC control panel, to the START
position and release switch when the unit has started.
Allow at least 30 seconds after shutdown before starting a hot engine. If the engine fails to
start after the first attempt, close the seacock before continuing. This will prevent sea water
from entering the engine cylinders through the exhaust valve.
After generator has started, check to be sure that water is flowing overboard from the
generator discharge. If there is no discharge, stop and check for leaks or obstructions.
Stopping
1. Run generator set at no load for five minutes to allow engine to cool down.
2. Switch the controller master switch, or the remote start switch on the AC control panel, to the STOP
position and wait until the generator set comes to a complete stop.
Circuit Protection
The AC circuit breaker on the generator controller will trip if a fault is detected in the AC output circuit. In
case of fault, refer to your generator owner's manual for troubleshooting information.
Only replace fuses with fuses of the same type (ABC or #AB (ceramic)) and ampere rating.
Do not use clear glass fuses.
Engine Shutdown Switches
The generator set engine is protected by three shutdown switches which automatically reset after the
engine cools down; or in the case of low oil pressure, if the problem is corrected.
Low Oil Pressure (LOP) – will shut down unit if pressure is 20 psi or less.
High Water Temperature (HWT) – will shut down unit if temperature is greater than 248°-
266°.
High Exhaust Temperature (HET) – will shut down unit if temperature is greater than
215° ± 5°.
CAUTION
CAUTION
CAUTION
CAUTION
!
WARNING
!
Содержание 268 SC Sport Cruiser
Страница 4: ......
Страница 15: ...M 11 VECTOR SERIES AIR CONDITIONER SELF CONTAINED UNIT WIRING DIAGRAM...
Страница 29: ...M 25 Use ATC series fuses 268 Bowrider and Cuddy Starboard Switch Panel Wiring Diagram...
Страница 30: ...M 26 268 Bowrider and Cuddy Ignition Panel Wiring Diagram...
Страница 31: ...M 27 268 Bowrider and Cuddy Instrument Panel Wiring Diagram...
Страница 32: ...M 28 268 Bowrider and Cuddy DC Wiring Diagram Main...
Страница 33: ...M 29 298 Bowrider AC Wiring Diagram Main 1 of 3...
Страница 35: ...M 31 298 Bowrider Water System...
Страница 36: ...M 32 298 Cuddy DC Wiring Diagram Main 1 of 5...
Страница 37: ...M 33 298 Bowrider DC Wiring Diagram Main 2 of 5...
Страница 78: ...OPERATION 4 10...
Страница 90: ...6 RUNNING 6 8...
Страница 106: ...STORAGE 9 4...
Страница 130: ...SHIP SYSTEMS 11 18...