Macerator Pump
A “Y” valve is installed between the pumpout plate and the macerator
discharge seacock. The macerator pump is located between the “Y”
valve and the macerator discharge seacock. In this configuration all
waste is flushed from the head to the holding tank. The “Y” valve per-
mits you to use the dockside pumpout feature, or to use the macera-
tor to pump the waste from the holding tank overboard.
Overboard discharge of waste should only be used in
approved areas. It is your responsibility to comply with
local regulations regarding the discharge of waste.
To pump out the holding tank using the macerator pump:
1.
Open the discharge seacock.
2.
Move the “Y” valve lever to the down or overboard position.
Do not run the pump dry. Running the pump when there
is no waste to pump out of the holding tank will shorten
the life of the pump.
3. Activate the macerator pump by turning its circuit breaker “ON.”
4. Close the macerator discharge seacock and turn macerator
pump “OFF” after the pumpout is complete.
Head Operating Instructions
Before operating the head for the first time, read the owner’s manual
for the marine toilet.
ELECTRICALLY OPERATED HEAD
1. Open the inlet water seacock below the cabin floor.
Overboard discharge of waste should only be used in
approved areas. It is your responsibility to comply with
local regulations regarding the discharge of waste.
2. If overboard discharge is to be used, make sure the “Y” valve is
in the overboard position, and that the macerator discharge sea-
cock is open.
!
CAUTION
!
CAUTION
!
CAUTION
KC-2046
TYPICAL MACERATOR SYSTEM
Y VALVE
DISCHARGE
SEACOCK
MACERATOR
PUMP
SHIP SYSTEMS
11-15
Содержание 268 SC Sport Cruiser
Страница 4: ......
Страница 15: ...M 11 VECTOR SERIES AIR CONDITIONER SELF CONTAINED UNIT WIRING DIAGRAM...
Страница 29: ...M 25 Use ATC series fuses 268 Bowrider and Cuddy Starboard Switch Panel Wiring Diagram...
Страница 30: ...M 26 268 Bowrider and Cuddy Ignition Panel Wiring Diagram...
Страница 31: ...M 27 268 Bowrider and Cuddy Instrument Panel Wiring Diagram...
Страница 32: ...M 28 268 Bowrider and Cuddy DC Wiring Diagram Main...
Страница 33: ...M 29 298 Bowrider AC Wiring Diagram Main 1 of 3...
Страница 35: ...M 31 298 Bowrider Water System...
Страница 36: ...M 32 298 Cuddy DC Wiring Diagram Main 1 of 5...
Страница 37: ...M 33 298 Bowrider DC Wiring Diagram Main 2 of 5...
Страница 78: ...OPERATION 4 10...
Страница 90: ...6 RUNNING 6 8...
Страница 106: ...STORAGE 9 4...
Страница 130: ...SHIP SYSTEMS 11 18...