Tools Required for Assembly (not included): Electrical Tape, Phillips Screwdriver, Pliers, Safety Glasses, Stepladder and Wire Strippers

WARNING:

 TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING

 READ AND SAVE THESE INSTRUCTIONS

Customer Service

800-969-3347

Customer Service Center

7400 Linder Ave.

Skokie, IL 60077

www.montecarlofans.com

2

© 2020 Monte Carlo Fan Collections

12/2020

Installation work and electrical wiring must be done by qualified person(s) in accordance with applicable codes and standards (ANSI/NFPA 70) including 

fire-rated construction.
Use this unit only in the manner intended by the manufacturer.  If you have  any questions contact the manufacturer.
After making the wire connections, the wires should be spread apart with the grounded conductor and the equipment-grounding conductor on one side 

of the outlet box and ungrounded conductor on the other side of the outlet box. The splices, after being made, should be turned upward and pushed 

carefully up into the outlet box.

WARNING:

 Before you begin installing the fan, servicing or cleaning unit, Switch power off at Service panel and lock service disconnecting means to 

prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning 

device, such as a tag, to the service panel.
Be cautious! Read all instructions and safety information before installing your new fan. Review the accompanying assembly diagrams.
When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
Make sure the installation site you choose allows the fan blades to rotate without any obstructions. Allow a minimum clearance of 7 feet from the floor 

to the trailing edge of the blade.

WARNING:

 To Reduce The Risk Of Fire, Electric Shock, or Personal Injury, Mount To Outlet Box Marked “Acceptable for Fan Support of 15.9 kg (35 lbs) 

or less” And Use Mounting Screws Provided With The Outlet Box.

CAUTION

: For Compliance with Local Codes and Regulations, If Installing The Secondary Support Safety Cable in the U.S., Do Not Remove Knockouts 

In The Outlet Box. Mount the secondary support safety cable through the reserved nail/screw hole on the outlet box to the building structure (or the 

ceiling joist).

WARNING:

 To reduce the risk of personal injury, do not bend blade holders during installation to motor, balancing or during cleaning.  Do not insert 

foreign object between rotating blades.
Attach the mounting bracket using only the hardware supplied with the outlet box.

WARNING:

 To reduce the risk of fire or electric shock, this fan must be installed with an isolating wall control/switch.

WARNING:

 To reduce the risk of fire or electric shock, this fan should only be used with fan speed control part no. JY1126R

 

manufactured by Satellite 

Electronic ( Zhongshan ) Ltd. 

WARNING:

 To reduce the risk of fire or electric shock, do not use this fan with any other solid state fan speed control device, or variable speed control.

If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application.
Never place a switch where it can be reached from a tub or shower.
The combustion airflow needed for safe operation of fuel-burning equipment may be affected by this unit’s operation. Follow the heating equipment 

manufacturer’s guideline safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for 

Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.

CAUTION:

 To Reduce the Risk of Electric Shock, Disconnect the electrical supply circuit to the fan before installing the light kit.

CAUTION:

 The light source is designed for this specific application and can overheat if serviced by untrained personnel. If any servicing is required, the 

product should be returned to an authorized service facility for examination or repair.  
All set screws must be checked and tightened where necessary before installation.

Note

: Suitable for use in damp locations. 

Содержание Hicks 3HCKR60 D Series

Страница 1: ...NAME RETAILER ADDRESS Attach sales receipt to this card and retain as your proof of purchase To register your fixture please visit our website www montecarlofans com 3HCKR60XXXD Series Fan cETL Model NO 3HCKR60XXD 8 7 kg 19 14 lbs Owner s Guide and Installation Manual ...

Страница 2: ...g 35 lbs or less And Use Mounting Screws Provided With The Outlet Box CAUTION For Compliance with Local Codes and Regulations If Installing The Secondary Support Safety Cable in the U S Do Not Remove Knockouts In The Outlet Box Mount the secondary support safety cable through the reserved nail screw hole on the outlet box to the building structure or the ceiling joist WARNING To reduce the risk of...

Страница 3: ...t corresponding to the slotted holes on the canopy upper ring Remove the other 2 set screws Save screws Use metal outlet box suitable for fan support and use only the screws provided with the outlet box must support 35 lbs Before attaching fan to outlet box ensure the outlet box is securely fastened by at least two points to a structural ceiling member a loose box will cause the fan to wobble Remo...

Страница 4: ...tended the lead wires are longer than the cable and no stress is placed on the lead wires Note If Installing The Secondary Support Safety Cable in the U S Do Not Remove Knockouts In The Outlet Box Make wiring connections using wire connectors provided as indicated above Brown wire from fan to Brown wire from receiver marked Motor U Gray wire from fan to Gray wire from receiver marked Motor V Orang...

Страница 5: ...n Save screw Connect white wire from fan to white wire from LED light fixture and then connect blue or black wire from fan to black or blue wire from LED light fixture Be sure plugs connection clasped together firmly Attach LED light fixture onto the light pan aligning the keyhole slots on the LED light fixture with the preassembled screws on the light pan Twist clockwise till lock Reinstall the s...

Страница 6: ...assembly by locating dimples in light pan with grooves on the blanking plate and twist clockwise until tight Note Do not install LED light fixture if use blanking plate Place the blanking plate in position and install the bottom plate and top ring with the set screws removed in installation step 17 Blanking plate assembly Install Blanking Plate Top ring Bottom plate Glass Top ring Bottom plate Bla...

Страница 7: ... for 30 seconds then automatically change to 5th 4th 3rd 2nd 1st at intervals of 30 seconds and then change it from Low speed 1st to 2nd 3rd 4th 5th 6th repeat the cycle until the breeze mold is canceled Breeze mold can be erase by pressing the buttons of power or speed control Note This remote controller has auto resume function the fan and light will maintain the last setting if turned off with ...

Страница 8: ... magnetic metal materials by a magnet built in the transmitter Wall mount cradle Tips for end users 1 If your fan is operated automatically after installation and power on it is because your fan is still memorize the previous setting at factory Make Remote control setting learn function and your fan will be ready for use 2 If fan or light isn t working reset power turn the power off then turn the ...

Страница 9: ...ng plate are tightened securely to 4 Check that all blade holders are tightened securely to motor 5 Most fan wobble problems are caused when blade levels are unequal Check this level by selecting a point on the ceiling above the tip of one of the blades Measure this distance from blade tip to ceilng Keeping measure within 1 8 rotate the fan until the next blade is positioned for measurement Repeat...

Страница 10: ...Jan 2021 ...

Отзывы: