© 2011 Monte Carlo Fan Company
2/2/2012
5
Remove 4 screws and save to install
switch housing.
19
Place and press firmly on the capaci-
tor to stick it to the switch housing.
Be sure it is secure.
22
Black capacitor box needs to be
stuck to the switch housing. Not
being attached can cause motor
noise.
Remove twin adhesive tape from the
black capacitor as shown above.
21
20
Install the switch housing using the 4
screws previously removed.
Setting the reverse switch in the
left hand side will result in down-
ward airflow and setting the
switch in the right hand side will
result in upward airflow.
Reverse switch
Содержание AC-560M