Installation work and electrical wiring must be done by qualified person(s) in accordance with  applicable codes ANSI/NFPA 70-1999),

including fire-rated construction.

Use this unit only in the manner intended by the manufacturer.  If you have  any questions contact the manufacturer.

After making the wire connections, the wires should be spread apart with the grounded conductor and the equipment-grounding con-

ductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box.

Before you begin installing the fan, Switch power off at Service panel and lock service disconnecting means to prevent power from

being switched on accidentally.  When the service disconnecting means cannot be locked, securely fasten a prominent warning device,

such  as a tag, to the service panel.

Be cautious! read all instructions and safety information before installing your new fan. Review the accompanying assembly diagrams.

When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

Make sure the installation site you choose allows the fan blades to rotate without any obstructions. Allow a minimum clearance of 7

feet from the floor to the trailing edge of the blade.

To reduce the risk of fire, electric shock, or personal injury, mount to outlet box or supporting system acceptable for fan support and 

use only the screws provided with the outlet box. (Mounting must support at least 35 lbs.)

Do not bend blade holders during installation to motor, balancing or during cleaning.  Do not insert foreign object between rotating

blades.

Attach the mounting bracket using only the hardware supplied with the outlet box.

To reduce the risk of fire or electric shock, do not use this fan with any solid state fan speed control device, or variable speed control.

The combustion airflow needed for safe operation of fuel-burning equipment may be affected by this unit’s operation. Follow the heat-

ing equipment manufacturer’s guideline safety standards such as those published by the National Fire Protection Association (NFPA),

and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.

Before servicing or cleaning unit, Switch power off at Service panel and lock service disconnecting means to prevent power from being

switched on accidentally.  When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such

as a tag, to the service panel.

Airflowdirection: warm weather-switch to left - forward / cool weather -switch to right - reverse

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS,

OBSERVE THE FOLLOWING: READ AND SAVE THESE INSTRUCTIONS

S

AFETY

T

IPS

TOOLS REQUIRED

Phillips Screwdriver      Wire Cutters       Pliers      Step Ladder

Before you begin installing the fan, Switch

power off at Service panel and lock service dis-

connecting means to prevent power from being

switched on accidentally.  When the service dis-

connecting means cannot be locked, securely

fasten a prominent warning device, such as a

tag, to the service panel.

Before installing this fan make sure the outlet box is

properly installed to the house structure.  To reduce

the risk of fire, electric shock, or personal injury,

mount to outlet box or supporting system acceptable

for fan support. (Mounting must support at least 35

lbs.)

Loosen the 2 set screws in yoke for

downrod to slip into yoke. Insert

downrod into yoke on top of the Fan

Body.  Align the hole in the Downrod

with the hole in the Yoke. Insert the

Pin through the Yoke and Downrod

until the point appears on the other

side.  Install the Keeper Pin

Tighten the 2 Set screws on the Yoke

once the downrod is in place. 

2

1

5

6

Yoke

Cross Pin

Keeper 

Pin

Installation

Use metal outlet box suitable for fan support

and use only the screws provided with the out-

let box  (must support 35 lbs). Before attach-

ing fan to outlet box, ensure the outlet box is

securely fastened by at least two points to a

structural ceiling member ( a loose box will

cause the fan to wobble). 

Use only the

screws provided with the outlet box.  

3

Thread canopy and yoke cover on down-

rod, Thread leadwires and safety cable

through the downrod.

Follow inserts as

shown above.

4

Canopy

Yoke cover

Downrod  

Ball

Содержание 5VSR60XXD Series

Страница 1: ...ETL model no 5VSR60 Ceiling Fan Installation Instructions For 5VSR60XXD Series Fans READ AND SAVE THESE INSTRUCTIONS Total fan weight OWNER S MANUAL Install with or without the light kit ...

Страница 2: ...National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities Before servicing or cleaning unit Switch power off at Service panel and lock service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominen...

Страница 3: ...e blade you select is facing downward Install 3 screws and fiber wash ers to back side of blade as shown Tighten screws securely Repeat this process 4 more times until all blades are assembled 12 For installation with light kit go to next step 16 For installation without light kit go to step 14 9 House Fan Black White Green Black White Green downrod Green Bracket Make sure that all exposed wiring ...

Страница 4: ...the rubber pad and hex nut onto the threaded rod secur ing the glass 24 Connect white wire from fan to white wire from light fixture Then plug blue wire from fan to black wire from light fixture by pushing together the connectors 19 Install 3 x 40 watt Candelabra base bulbs Bulbs Not included 22 Install the decorative finial nut to the threaded rod by screwing on securely 25 Loosen 2 screws and re...

Страница 5: ... es on the fan Only change the remote DIP switches then press SET See next pg for details FAN REVERSE Press once to change direction of the fan with fan running FAN OFF SETTING Turns fan off only LIGHT ON OFF SET TING AND DIMMER Press and hold to dim light infinitively Red LED indicator Speed 1 Speed 2 Speed 3 Speed 6 Speed 5 Speed 4 DIP switches SET button Battery Compartment ...

Страница 6: ... seconds The fan will go to the last factory setting This could be any speed or off If you have more than 1 fan with the Remote controller you will have to change the DIP switch settings of the Remote Transmitter located beside the battery compartment of the remote There is no dip switch on the Receiver Make sure that the power is off to at least one of the fans Use the steps above to set the lear...

Страница 7: ...el by selecting a point on the ceiling above the tip of one of the blades Measure this distance from blade tip to ceil ng Keeping measure within 1 8 rotate the fan until the next blade is positioned for measurement Repeat for each blade If all blade levels are not equal you can adjust blade levels by the following procedure To adjust a blade tip down insert a washer not supplied between the blade ...

Отзывы: