background image

© 2013 Monte Carlo Fan Company

6/15/2013

3

Before you begin installing the fan, Switch power off

at Service panel and lock service disconnecting

means to prevent power from being switched on ac-

cidentally.  When the service disconnecting means

cannot be locked, securely fasten a prominent warn-

ing device, such  as a tag, to the service panel.

1

Before installing this fan make sure the outlet

box is properly installed to the house structure.

To reduce the risk of fire, electric shock, or per-

sonal injury, mount to outlet box or supporting

system acceptable for fan support. 

(Mounting must support at least 35 lbs.)

2

Thread safety cable through center

hole of the mounting plate. Thread

your house wires through center hole

also.These will be needed for wiring

of the fan.

4

Securely attached the mounting plate

to the outlet box using two screws

supplied by the outlet box. 

Use

metal outlet box suitable for fan

support (must support 35 lbs).

6

Place the decorative ring on the

motor housing.

3

Make wire connections to power source using

wire nuts provided.  Make sure that no filiments

are outside of the wirenut. After making the

wire connections, the wires should be spread

apart with the grounded conductor and the

equipment-grounding conductor on one side of

the outlet box and ungrounded conductor on the

other side of the outlet box.  

9

Connect black and blue wire from fan to Black

or (Hot) wire from house.  Connect White wire

from Fan to White (Neutral) wire from house.

Connect Ground leads from mounting bracket

and downrod to Ground lead from house.

Refer to Safety Tips section of manual.

8

Carefully lift the fan motor assembly

and engage the slot in the motor

housing with the hook on the mount-

ing plate so that the motor is se-

curely suspended.

7

For Canadian installation and for USA fan and

light kit combinations over 35 lbs, in both flush

and downrod mode the safety cable must be in-

stalled into the house structure beams using the

3” lag screws provided.  Make sure that when

the safety cable is fully extended the leadwires

are longer than the cable and no stress is placed

on the leadwires. 

Note

:If Installing The Second-

ary Support Safety Cable in the U.S., Do Not Re-

move Knockouts In The Outlet Box. 

5

Safety cable installation

Safety Cable

Lag Screw

Lag Screw

Safety Cable

Washer

Lock Washer

Содержание 5TV52XXD Series

Страница 1: ...is card and retain as your proof of purchase DATE OF PURCHASE MODEL NUMBER RETAILER NAME RETAILER ADDRESS To register your fixture please visit our website www montecarlofans com 5TV52XXD Series Fan Total fan weight with light kit UL Model No 5TV52 10 6 kgs 23 4 lbs ...

Страница 2: ...Use Mounting Screws Provided With The Outlet Box CAUTION For Compliance with Local Codes and Regulations If Installing The Secondary Support Safety Cable in the U S Do Not Re move Knockouts In The Outlet Box Mount the secondary support safety cable through the reserved nail screw hole on the outlet box to the building structure or the ceiling joist WARNING To reduce the risk of personal injury do ...

Страница 3: ... Make sure that no filiments are outside of the wirenut After making the wire connections the wires should be spread apart with the grounded conductor and the equipment grounding conductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box 9 Connect black and blue wire from fan to Black or Hot wire from house Connect White wire from Fan to White Neutral wire...

Страница 4: ... decorative ring up and twist clockwise till tight 12 Check the motor for shipping stabiliz ers and remove if present Attach blades using screws and washers in hardware pak Tighten screws se curely 13 Loosen 2 screws and remove 1 screw from motor plate Save removed screw for use later 14 Connect plug from fan to switch house plug 16 Install by twisting clockwise add 1 screw removed step 14 to swit...

Страница 5: ...light fixture with the grooves in the non light kit cover and twist clockwise till tight WARNING Make sure light bulb is not installed when using this cover 22 Install 75 watt halogen bulb Do not touch bulb surface as oily residue from skin can cause the bulb to explode Bulb Included WARNING Over lamping the fan will result in the fan lights shut ting down until the proper wattage of bulbs are ins...

Страница 6: ...low break in period of 24 hours Most noises associated with a new fan will disap pear after this period 1 If this is a downrod mount fan make sure the ridge on mounting bracket engages the notch in the downrod ball 2 Check that all blades are screwed firmly into blade holders 3 Check that all blade holders are tightened securely to motor 4 Make sure that canopy and mounting bracket are tightened s...

Страница 7: ...Jan 2012 Update customer service phone number Jun 2013 Update for CUL regulation ...

Отзывы: