background image

1.Check main and branch circuit fuses or circuit breakers.

2.Check line wire connections to fan and switch wire connections in switch housing.

CAUTION:  Make sure main power is turned off.

3.Make sure forward/reverse switch is firmly in up or down position.  Fan will not operate when

switch is in the middle.

4.Make sure that shipping stabilizer tabs have been removed from motor.

1.Check to make sure all screws in motor housing are snug (not over tightened).

2.Check to make sure the screws which attach the fan blade holder to the motor are tight.

3.Check to make sure wire nut connectors in switch housing are not rattling against each other or

against the interior wall of the switch housing.

CAUTION:  Make sure main power is turned off before entering switch housing.

4.If using an optional Ceiling Fan Light Kit, check to be sure the screws securing the glassware are

finger tight.  Check to be sure light bulb is tight in socket and not touching glass shade(s). If

vibration persists from glass, remove glass and install a 1/4" wide rubber band on glass neck to

act as an insulator. Replace glass and tighten screws against rubber band. 

5.Some fan motors are sensitive to signals from Solid State variable speed controls.  DO NOT

USE a Solid State variable speed control.

6.Allow "break-in" period of 24 hours.  Most noises associated with a new fan will disappear after

this period.

1.Make sure that the ridge of the canopy engages the notch in the downrod ball.  (See illustration

in Step #6 of Downrod Mount installation).

2.Check that all blades are screwed firmly into blade holders.

3.Check that all blade holders are tightened securely to motor.

4.Make sure that canopy and mounting bracket are tightened securely to ceiling junction box and

junction box is mounted firmly to ceiling joist.

5.Most fan wobble problems are caused when blade levels are unequal. Check this level by select-

ing a point on the ceiling above the tip of one of the blades. Measure this distance from blade tip

to ceilng. Keeping measure within 1/8", rotate the fan until the next blade is positioned for meas-

urement. Repeat for each blade. If all blade levels are not equal, you can adjust blade levels by

the following procedure. To adjust a blade tip down, insert a washer (not supplied) between the

blade and blade holder at the screw closest to the motor. To adjust a blade tip up, insert washer

(not supplied) between the blade and blade holder at the two screws farthest from the motor.

Reverse the position of the washer if blades mount from top of blade.

6.If blade wobble is still noticeable, interchanging two adjacent (side by side) blades can redistrib-

ute the weight and possibly result in smoother operation.

1.Check blue wire from fan to make sure it is connected to hot wire from house

2.Check for loose or disconnected wires in fan switch housing.

3.Check for loose or disconnected wires in light kit.

4.Check for faulty light bulbs.

CAUTION:  Make sure main power is turned off before entering switch housing.

WARNING: USE MAXIMUM 13 WATTS LISTED SBCFL (SELF-BALLASTED

COMPACT FLUORESCENT LAMP) ONLY, NOT USING SBCFL WILL OVERHEAT THE UNIT

AND CAUSE DAMAGE TO THE UNIT OR THE FAN WHICH THE UNIT IS INSTALLED

TOGETHER.

2. If fan sounds noisy:

1. If fan does not start:

3. If fan wobbles:

4. If light does not work:

T

ROUBLE

S

HOOTING

If you have difficulty operating your new ceiling fan, it may be the result of incorrect assembly, installation, or wiring. In

some cases, these installation errors may be mistaken for defects. If you experience any faults, please check this Trouble

Shooting Chart. If a problem cannot be remedied, or you are experiencing difficulty in installation, please call our

Customer Service Center at the 

number printed on your parts list insert sheet. 

Warning: Before servicing or cleaning unit, Switch power off at Service panel and lock service disconnecting

means to prevent power from being switched on accidentally.  When the service disconnecting means cannot

be locked, securely fasten a prominent warning device, such  as a tag, to the service panel.

Customer Service Center:

301 West Washington St.

Riverside, NJ 08075

1-800-519-4092

www.montecarlofans.com

Содержание 5SH54XXD-L Series

Страница 1: ...Ceiling Fan Installation Instructions For 5SH54XXD L Series Fans READ AND SAVE THESE INSTRUCTIONS Total fan weight with light kit OWNER S MANUAL ...

Страница 2: ...not be locked securely fasten a prominent warning device such as a tag to the service panel To assure success of this installation be sure to read the instructions and review the dia grams thoroughly before beginning Follow the instructions that are applicable for your light kit Review the installation instructions supplied with your fan Make sure that your fan has been wired properly into the cei...

Страница 3: ...down remove the cross pin and save 7 Place the canopy over the downrod as shown above 11 Place the yoke cover over the down rod as shown above 10 Tighten the set screws securely 9 Thread the leadwires and safety cable through the downrod and place the downrod into the yoke Insert the clevis pin by aligning the holes from the yoke and downrod Insert the keeper pin into the end of the clevis pin 8 P...

Страница 4: ...lack capacitor box needs to be stuck to the switch housing Not being attached can cause motor noise Remove twin adhesive tape from the black capacitor as shown above 27 26 Hang assembled fan from the mounting bracket installed to ceiling in previous steps Make sure the fan is hanging straight Rotate fan until the tab on the Mounting bracket engages the slot on the Downrod Ball This must be done to...

Страница 5: ...cap 30 Place pull chain from fan through guide from light kit Be sure they are lined up vertically 38 Loosen 3 screws on the ridge of the light kit 35 Attach fob with connector to extend your pull chains 39 Push glass up into fitter and hand tighten the 3 screws to hold in place 37 Install keeper nut from the threaded pipe of the light kit Install the keeper nut from the lead wires 31 Remove 3 scr...

Страница 6: ...Attach switch cap to fan by lining up 3 screw holes and installing the 3 screws removed and saved from ear lier step Tighten screws securely 40 Installing without light kit ...

Страница 7: ...m blade tip to ceilng Keeping measure within 1 8 rotate the fan until the next blade is positioned for meas urement Repeat for each blade If all blade levels are not equal you can adjust blade levels by the following procedure To adjust a blade tip down insert a washer not supplied between the blade and blade holder at the screw closest to the motor To adjust a blade tip up insert washer not suppl...

Отзывы: